Skip to main content
{1}
##LOC[OK]##
{1}
##LOC[OK]##
##LOC[Cancel]##
{1}
##LOC[OK]##
##LOC[Cancel]##
Skip to main content
Home
|
Setup an Account
Log In
Public
Contractor
User Name:
CONSTRUCTION INC
PITTS, HANSEL LAUDEN JR- INDIVIDUAL
#1 COOLING & HEATING LLC
#1 R&R ELECTRICAL ALLSTAR
1 STOP SECURITY
1 STOP TOTAL SOLUTIONS LLC
1ST ALERT ROOFING
1ST CHOICE COOLING & HEATING INC
1ST CHOICE ELECTRICAL SERVICES
1ST CHOICE FACILITIES SERVICES
1ST CLASS PLUMBING LLC
1ST CLASS ROOFING INC
1ST IN FIRE & SAFETY LLC
1ST USA PLUMBING
2 NICE GUYS INC
2020 WINDOWS AND DOORS LLC
2FIX CORP
2H RESCREENING
2ND GEN ROOFING LLC
3 WAYS OF AIR LLC
3/8 AND CO., LLC
360 GC INC / ANTHONY WILEY
3D AIR SERVICES LLC
3D CONSTRUCTION SERVICES INC
3D ELECTRIC AND SONS LLC
3D SOLAR LLC
3G HOME EXTERIORS
3MG ROOFING
4C'S RESTORATION LLC
4H PLUMBING INC
5 STAR ELECTRICAL CONTRACTOR, LLC
5 STAR PLUMBING SERVICES CORP
5 STAR REFRIGERATION & A/C INC
5L UNDERGROUND & GAS SERVICES LLC
60HZ ELECTRIC LLC
75 LIGHTING & SIGNS LLC
7TH GENERATION HEATING & COOL
8:18 RENOVATION & RESTORATION, LLC
911 ROOFING AND CONSTRUCTION CORP
911 ROOFING AND RESTORATION INC
941 CONSTRUCTION LLC
A & E PROJECTS CORP
A AMERICAN ELECTRICAL CONTR
A AMERICAN FIRE CO LLC
A ARCHITECTURAL METALS INC
A BEACON ELECTRICAL SERVICES
A BETTER CHOICE SCREEN
A BREEZE ROOFING CO
A BUILDING CONCEPT OF SARASOTA INC
A C SCHULTES OF FLORIDA INC
A CLEAN FINISH INC
A FIRE SPRINKLERS INC
A GENERATOR GUY / ACCURATE POWER AND TECHNOLOGY
A HOME BUILDERS LLC
A NATIONAL ELECTRIC SERVICE
A OK ELECTRICAL SERVICES INC
A OLD TIME ROOFING
A PLUS ROOFING AND WATERPROOFING LLC
A PRECISION GENERAL CONTRACTOR
A RANDY'S ELECTRIC INC
A SPEEDY PLUMBING INC
A SQUARED ROOFING INC
A STEPPING STONE INC OF PLANT
A TEAM AMERICA ROOFING INC
A TO Z CONTRACTING & PLUMBING
A TO Z ELECTRIC INC
A TO Z GULFCOAST SERVICES LLC
A TO Z ROOFING SERVICES INC
A TOTAL SOLUTION INC
A UNDERGROUND ENTERPRISES LLC
A WINDOW PRO CONTRACTING INC
A&A ALARM SYSTEMS INC
A&A ELECTRIC SERVICE LLC
A&A GLOBAL ELECTRIC LLC
A&A HOME MAINTENANCE & HANDYMAN SERVICE
A&B ELECTRIC OF SARASOTA INC
A&B PLUMBING OF SW FLORIDA INC
A&E PLUMBING SERVICES LLC
A&J CONSTRUCTION SERVICES INC
A&K ENERGY CONSERVATION INC
A&L CONSTRUCTION SERVICES INC
A&L PLUMBING SPECIALISTS LLC
A&L PROJECTS INC
A&M DESIGN GROUP INC
A&M ELECTRIC CONTRACTOR LLC
A&R FIRE FEATURES LLC
A&R QUALITY HOMES INC
A&S CITRUS PLUMBING INC
A&T PLUMBING INC
A&W SPECIALTY CONTRACTING
A&Y CONSTRUCTION INC
A'S STAR ROOFING INC
A+ ELECTRIC LLC
A+ ENVIRONMENTAL RESTORATION LLC
A+ GARAGE DOORS INC
A+ SEPTIC & PLUMBING INC
A++ PROFORMANCE PLUMBING INC
A-1 AFFORDABLE PLUMBING INC
A-1 AMERICAN ROOFING & SHEET METAL INC
A-1 COMMERCIAL PLUMBING INC
A-1 GAS & POOL CONTROL INC
A-1 PLUMBING OF SARASOTA INC
A-1 POOL FINISHERS OF VENICE
A-1 SECURITY ALARMS INC
A-1 TECHNOLOGIES INC
A-EXCELLENT SERVICE
A-FIRST CHOICE ROOFING
A-ONE EVERYTHING ELECTRICAL
A-PLUS PLUMBING SERVICES
A-TEAM AIRCONDITIONING CO
A-TEAM UNDERGROUND LLC
A-TECH PLUS INC.
A-TRU PLUMBING, LLC
A.B.T. ROOFING & RESTORATION L.L.C.
A.F. PLUMBING LLC
A.M. ROOFING & WATERPROOFING INC
A.R.T. GENERAL CONTRACTOR LLC
A/C WAREHOUSE, INC
A1 WINDOWS & DOORS
A2 GROUP INC
A2Z CONSTRUCTION LLC
AA ACTION ELECTRIC INC
AA FLORIDA COAST BUILDERS CORP
AA MASTERS MECHANICAL AIR MOVE
AAA FIRE PROTECTION
AAA MANUFACTURED HOUSING INC
AAA ON TIME ELECTRIC INC
AAA PLUMBING INC
AAA POOL SERVICE INC
AAA ROOFING LLC
AAA ROOFMASTERS INC
AAA SCHWARTZ ROOFING INC
AAA SOLAR SOURCE
AALL TERRAIN CONSTRUCTION INC
AAP INDUSTRIAL INC
AAP SERVICES
AARONS ELITE POOL SERVICE LLC
AB FIRE EQUIPMENT INC
ABA ROOFING & CONSTRUCTION LLC
ABA-CON INC
ABACO ALUMINUM CO INC
ABASH ENTERPRISES INC
ABBOTT AIR INC
ABBOTTS CONSTRUCTION SERVICES
ABBY AWNINGS & CANVAS LLC
ABC CONSTRUCTION OF ENGLEWOOD
ABC COOLING & HEATING INC
ABC FIRE EQUIPMENT CORP
ABC PHASE ELECTRIC
ABC SOUTHWEST COMPANY INC
ABE SHULTZ CONSTRUCTION LLC
ABE'S ELECTRIC INC
ABI COMPANIES INC
ABISSO ABATEMENT INC
ABISSO REMODELING INC
ABLE ELECTRIC OF ENGLEWOOD INC
ABLE INC
ABM BUILDING SERVICES
ABOUT TIME PLUMBING & DRAIN
ABOVE ALL ALUMINUM LLC
ABOVE AND BEYOND EXTERIORS, INC
ABOVE AND BEYOND POOLS INC
ABP ELECTRIC
ABSOLUTE AIR SOLUTIONS LLC
ABSOLUTE ALUMINUM & CONSTRUCTION CO
ABSOLUTE ALUMINUM (DESJARDINS)
ABSOLUTE ELECTRIC OF SW FL INC
ABSOLUTE METAL ROOFING INC
ABSOLUTE PLUMBING SERVICES INC
ABSOLUTE ROOFING OF FLORIDA
ABSOLUTE TEMPERATURE LLC
ABSOLUTE WINDOW & DOOR
ABSOLUTE WINDOW & SHUTTER (PUNTA GORDA)
ABSOLUTE WINDOW LLC
ABT CONSTRUCTION INC
AC COASTAL LLC
AC COMPANY SARASOTA LLC
AC DELTA ELECTRIC CO INC
AC FAST SOLUTIONS
AC HEROES LLC
AC INTEGRAL CONSTRUCTION, LLC
AC OUTFITTERS LLC
AC PARTNERS OF FLORIDA INC
AC PROS
AC TODAY INC
AC/DC SOLAR LLC
AC1 LLC
ACCENT AIR CONDITIONING & MECHANICAL INC
ACCENT CONSTRUCTION & REMODEL
ACCENT CONSTRUCTION SERVICES INC
ACCENT ELECTRONIC SYSTEMS
ACCENT FENCE & LAWN
ACCENT FENCE & LAWN INC
ACCENT HEATING & AIR CONDITIONG INC
ACCESS CONTROL TECHNOLOGIES
ACCESS ELECTRICAL CONTRACTORS INC
ACCESS FIRE PROTECTION INC
ACCESS RESTORATION SERVICES US, INC.
ACCU-TEMP MECHANICAL SERVICES
ACCURACY ELECTRIC LLC
ACCURATE BACKFLOW TESTING INC
ACCURATE ELECTRICAL CONNECTION INC
ACCURATE GAS & PLUMBING LLC
ACCURATE GENERAL CONTRACTOR
ACCURATE HEATING & COOLING INC
ACCURATE SECURITY AND ELECTRIC
ACCUTECH RESTORATION & REMODELING INC
ACDC AIR CONDITIONING
ACE AIR CONDITIONING & ELEC
ACE AIR CONDITIONING & ELEC
ACE AIR CONDITIONING & ELEC
ACE ALUMINUM & CONSTRUCTION
ACE AMERICAN HOME
ACE CONTRACTING OF FLORIDA
ACE ELECTRIC INC
ACE ELECTRICAL SYSTEMS INC
ACE HANDYMAN SERVICES SARASOTA VENICE
ACE PLUMBING INC
ACE PRO CONTRACTING LLC
ACI/ BOLAND INC
ACKERMAN PLUMBING INC
ACME AIR & REFRIGERATION
ACME AWNINGS INC
ACME PLUMBING
ACME TRANSPORT INC
ACORN STAIRLIFTS INC
ACPLM, INC
ACR1.COM COMMERCIAL ROOFING
ACREE AIR CONDITIONING LLC
ACREE PLUMBING AIR & ELECTRIC-M
ACREE PLUMBING AIR & ELECTRIC-P
ACS HOME SERVICES
ACT FIRE PROTECTION INC
ACT ROOFING
ACTION A/C OF SARASOTA INC
ACTION AIR OF SARASOTA
ACTION AUTOMATIC DOOR & GATE
ACTION COOLING & HEATING INC
ACTION ELECTRIC COMPANY
ACTIVE DOOR & WINDOW CO
ACU TEMP REFRIGERATION INC
AD-LER ROOFING INC
ADA CONSTRUCTION GROUP INC.
ADAMS & COCKRILL POOL SERVICE
ADAMS CONSTRUCTION SERVICES, LLC
ADAMS HOME AND MAINTENANCE SERVICE INC
ADAMS HOMES OF NORTHWEST FLORIDA, INC
ADAMS TANK & LIFT INC
ADAMZ ROOFING INC
ADECA DESIGN, LLC
ADIRONDACK AIR LLC
ADL DEMOLITION & LAND CLEARING
ADMIRAL SERVICES INC
ADS SERVICES INC
ADT COMMERCIAL LLC
ADT SECURITY SERVICES
ADT SOLAR LLC
ADVANCE ALUMINUM AND SCREEN, INC
ADVANCE SOLAR & SPA INC
ADVANCE SOLAR CONSTRUCTION LLC
ADVANCED AIR & REFRIGERATION INC
ADVANCED ALARM SERVICES
ADVANCED ALUMINUM AND SCREEN
ADVANCED ALUMINUM ARCHITECTURAL SCREENING LLC
ADVANCED ALUMINUM INC
ADVANCED ASPHALT OF SW FLA INC
ADVANCED AUDIO DESIGN
ADVANCED BUILDING STRUCTURES LLC
Advanced Climate Solutions FL, LLC
ADVANCED COMMERCIAL CONTRACTOR
ADVANCED COMMERCIAL ROOFING
ADVANCED ELECTRICAL SERVICES INC
ADVANCED ELECTRICAL SOLUTIONS INC
ADVANCED ELECTRICAL SYSTEMS
ADVANCED ENGINEERED SYSTEMS
ADVANCED FIRE EQUIP CENTRAL FL
ADVANCED FIRE SYSTEMS INC.
ADVANCED HOME ELECTRICAL SOLUTIONS LLC
ADVANCED HOME WINDOW AND DOOR LLC
ADVANCED INC /ADVANCED ROOFING
ADVANCED MECHANICAL SERVICES
ADVANCED METAL ROOFING INC
ADVANCED MODULAR STRUCTURES INC
ADVANCED PLUMBING & INSTALLATIONS INC
ADVANCED PLUMBING SOLUTIONS & DESIGN LLC
ADVANCED POWER TECHNOLOGIES
ADVANCED REFRIGERATION & AIR
ADVANCED ROOFING & SHEETMETAL, LLC
ADVANCED ROOFING INC
ADVANCED SECURITY SOLUTIONS INC
ADVANCED WATER TECHNOLOGIES
ADVANCED WINDOW CONCEPTS INC
ADVANTAGE A/C OF INDIAN RIVER
ADVANTAGE AIR SERVICES INC
ADVANTAGE ROOFING & CONSTRUCTION LLC
ADVANTECH GC LLC
ADVANTEK ROOFING INC
ADVENTURE HOT TUBS & POOLS
AEC SERVICES INC
AEC-ELECTRICAL CONTRACTORS LLC
AEGIS FIRE AND INTEGRATED SERVICES, LLC
AEGIS PLUMBING SERVICES LLC
AEGIS PROPERTY SERVICES LLC
AEI ELECTRICAL CONSTRUCTIONS
AEON ENTERPRISE'S LLC
AERIAL CONSTRUCTION TECHNOLOGY LLC
AERO ELECTRIC INC
AES MECHANICAL SERVICES GROUP
AFA PROTECTIVE SYSTEMS INC
AFFORDABLE HEATING & COOLING
AFFORDABLE HOME SOLUTIONS OF FLORIDA, LLC
AFFORDABLE HURRICANE SYSTEMS
AFFORDABLE ROOFING & GUTTERS OF FLORIDA INC
AFFORDABLE ROOFING SYSTEMS, INC.
AFFORDABLE SCREENING, LLC
AFFORDABLE SOLAR ROOF & AIR LLC
AFFORDABLE WINDOWS & DOORS OF TAMPA BAY LLC
AFFORDABLE WINDOWS SYSTEMS INC
AG STAR CONSTRUCTION INC
AGAPE HOMES AND REMODELING LLC
AGE TO PERFECTION RENOVATIONS LLC
AGILE ELECTRIC LLC
AGRIESTI AIR CONDITIONING LLC
AGUILA ELECTRICAL SERVICES, INC.
AIN'T GONNA FIX ITSELF INC.
AIP GENERAL CONTRACTORS INC
AIR & HEAT INC
AIR 360 HEATING & COOLING LLC
AIR 4 YOU INC
AIR AMERICA HOLMES BEACH
AIR AROUND THE CLOCK
AIR ASSAULT AIR COND & HEATING
AIR AUTHORITIES OF TAMPA BAY
AIR BALANCE TECHNOLOGY INC
AIR CARE OF SARASOTA INC
AIR CLEAN OF FLORIDA
AIR COMFORT SERVICES LLC
AIR CONDITION REPLACE EXPERTS
AIR CONDITIONING & MECHANICAL DIAGNOSTICS INC.
AIR CONDITIONING DISCOUNT COOL INC
AIR CONDITIONING PROS
AIR CONDITIONING XPERTS INC
AIR EXPERTS
AIR FORCE 1 OF SOUTHWEST FL
AIR HANDLERS COOLING & HEATING
AIR MASTER HEATING & COOLING
AIR MASTER HEATING AND COOLING LLC
AIR MECHANICAL & SERVICE CORP
AIR NOW
AIR ONE HEATING & COOLING
AIR QUALITY CONDITIONING INC
AIR REPAIR HVAC INC
AIR SERVICE OF MANASOTA INC
AIR SHIELD HEATING & COOLING LLC
AIR SPECIALISTS LLC
AIR SUPPORT COOLING & HEATING
AIR SYSTEM SERVICE INC
AIR TECH COOLING & HEATING INC
AIR TECH HEATING & COOLING INC
AIR TECH OF CENTRAL FLORIDA
AIR TECH SERVICES INC
AIR TECHNICIANS INC
AIR TECHS OF VOLUSIA LLC
AIRASOTA, LLC
AIRCO MECHANICAL CONTRACTORS
AIRCOM OF TAMPA BAY INC
AIRCON COMFORT COOLING, LLC
AIRE TODAY LLC
AIRESCUE
AIRESTRIKE COOLING AND HEATING INC
AIRGENX CLEAN CLIMATE SOLUTIONS LLC
AIRLOCK HOMES LLC
AIRPRO HEATING COOLING VENTILATION
AIRRIFIC INC
AIRSTRON INC
AISG
AJAX BUILDING COMPANY LLC
AJAX BUILDING CORP
AJAX PAVING INDUSTRIES OF FLA
AJAX/TANDEM CONSTRUCTION,A JV
AJB HOME SOLUTIONS LLC
AJF CONSTRUCTION LLC
AK CERTIFIED CONTRACTING LLC
AK ELECTRICAL LLC
AKVM CONSTRUCTION GROUP INC
AL BOSGRAAF & SONS INC
AL WANG CONSTRUCTIONS INC
ALADDIN WARD ELECTRIC
ALAN BATES LLC
ALAN J STEVENS LLC
ALAN MCEACHERN ENTERPRISES LLC
ALAN'S ROOFING & CONSTRUCTION
ALARM & ENTERTAINMENT SERVICES
ALARM DESIGN SOLUTIONS LLC
ALARM MONITORING & SERVICE INC
ALARM TEAM INC
ALARM TECHS INC
ALBERT WAGNER CONSTRUCTION INC
ALBO CONSTRUCTION LLC
ALCOA WIRELESS SERVICES INC
ALDAY TREE SERVICE
ALDO BOLDI INTERIOR DESIGN INC
ALECO AC & HEATING EXPERTS
ALEJANDRO TOVAR DBA TCA FENCES CORP
ALERT FIRE SPRINKLERS INC
ALEX MICHAEL FITE
ALEX THE PLUMBER LLC
ALEX'S POOL HEATING & AC LLC
ALEXANDER DEVELOPMENT
ALEXANDER ROOFING & REPAIR LLC
ALEXANDER, JESSICA
ALF CONTRACTING LLC
ALFORD CONSTRUCTION INC - BARRY ALFORD
ALFRESCO AIR INC
ALICIA CHAPMAN (OWNER BUILDER)
ALKEMA ELECTRIC INC
ALL 4 ONE CONSTRUCTION & PLUMBING INC.
ALL ABOUT ALUMINUM & SCREEN INC
ALL ABOUT GENERATORS INC
ALL ABOUT PLUMBING
ALL ABOUT ROOFING
ALL ABOUT ROOFING & MORE INC
ALL AIR & HEATING
ALL AMERICAN AIR & ELECTRIC
ALL AMERICAN ALUMINUM
ALL AMERICAN ALUMINUM SPECIALIST INC
ALL AMERICAN DECKS AND SPAS
ALL AMERICAN ENTERPRISES OF SARASOTA
ALL AMERICAN FENCING LLC
ALL AMERICAN GAS SERVICE
ALL AMERICAN HEATING & COOLING INCORPORATED
ALL AMERICAN SHUTTERS & GLASS
ALL AMPS ELECTRIC LLC
ALL AREA ROOFING & WATERPROOFING, INC
ALL ASPECTS PLUMBING, LLC
ALL BRANDS COOLING AND HEATING, LLC
ALL BRANDS WINDOW SERVICE & GLASS INC
ALL CITIES AIR CONDITIONING INC
ALL COUNTY IMPROVEMENTS INC
ALL COUNTY MAINTENANCE & REPAIRS INC
ALL DAY ELECTRIC INC
ALL DAY ROOFING & WATERPROOF
ALL DIGITAL TECHNOLOGY
ALL ELECTRIC OF SARASOTA INC
ALL FLORIDA CUSTOM HOMES BY JOHN RAYMOR
ALL FLORIDA MANUFACTURED HOME
ALL FLORIDA MECHANICAL SERVICES INC
ALL FLORIDA SIGNS & NEON SERVICES
ALL FLORIDA STATE ROOFING LLC
ALL FLORIDA WEATHERPROOFING & CONSTRUCTION
ALL GAS PROS, LLC
ALL GLASS & WINDOWS INC
ALL GOOD A/C LLC
ALL LAKE ELECTRICAL CONTRACTORS INC
ALL PHASE ELECTRIC & MAINTENANCE INC
ALL PHASE ELECTRIC SERVICE OF FL
ALL PHASE PLUMBING, LLC
ALL PHASES MOBILE HOME INC
ALL POOL & DECK RENOVATIONS
ALL POWER ELECTRIC LLC
ALL PRO PROPERTY SERVICES INC
ALL PRO WATER HEATERS
ALL PRO XTERIOR INC
ALL QUALITY ELECTRICAL CONSTRUCTION INC
ALL SEASONS COMFORT
ALL SEASONS COMFORT SPECIALIST
ALL SEASONS HEATING & A/C INC
ALL SEPTIC ALL PLUMBING INC.
ALL SERVICE ELECTRIC FT MYERS
ALL SERVICE PLUMBING & MECHANICAL
ALL STAR PLUMBING
ALL STEEL BUILDINGS/COMPONENTS
ALL STEEL CONSULTANTS INC
ALL STORM PROTECTION LLC
ALL SURFACE ROOF COATINGS INC
ALL TECH CONSTRUCTION & MAINT
ALL TECH HEATING & COOLING INC
ALL TRADES INSPECTIONS & CONSULTING
ALL TRADES OF CONSTRUCTION & RESTORATION INC
ALL UNITED CONTRACTING INC
ALL WAYZ PLUMBING SERVICES INC
ALL WEATHER CONTRACTORS INC
ALL WEATHER ROOFING
ALL WEATHER ROOFING OF FLORIDA
ALL WEATHER TITE INC
ALL WIRE ELECTRIC LLC
ALL YOU NEED SERVICES LLC
ALL-STATE PLUMBING SERVICES INC
ALL-TECH ELECTRICAL INC
ALLAN ELECTRIC INC
ALLEN INDUSTRIES INC
ALLEN PLUMBING INC
ALLEY GATOR ELECTRIC
ALLGOOD HOME IMPROVEMENT
ALLIANCE FIRE & SAFETY (FOWLER)
ALLIANCE FIRE & SAFETY (HILL)
ALLIANCE FIRE & SAFETY (HINSBERG)
ALLIANCE FIRE & SAFETY (RENICK)
ALLIANCE FIRE & SAFETY (WILLIS)
ALLIANCE HOME REPAIR & RENOVAT
ALLIANCE POWER SOLUTIONS INC
ALLIED CONTRACTORS GROUP, INC.
ALLIED COOLING & HEATING LLC
ALLIED DOORS INC
ALLIED ROOFING INC
ALLIED SIGNAGE
ALLIGATOR PLUMBING SUPPLY
ALLPRO HOME IMPROVEMENT & SERVICES, LLC
ALLSPARK ELECTRICAL SERVICES, LLC
ALLSTAR ELECTRICAL EXPERTS, INC
ALLSTAR POOLS OF SARASOTA INC
ALLSTATE CONSTRUCTION ROOFING INC
ALLSTATE EXTERIORS LLC
ALLSTATE FIRE PROTECTION
ALLSTATE PSP, LLC
ALLTEC PLUMBING LLC
ALLTECH SPECIALISTS INC
ALMA ELECTRIC LLC
ALMONTE ELECTRICAL SOLUTIONS LLC
ALOHA AIR HEATING & COOLING
ALPHA COOLING INC
ALPHA ELECTRIC INC OF TAMPA
ALPHA ELECTRIC SERVICES INC
ALPHA FOUNDATIONS
ALPHA ROOFING CO.
ALPHA SPRAY FOAM INC
ALPHA-OMEGA COMMUNICATIONS LLC
ALPINE SOUTH PLUMBING CORP
ALSPACH CONSTRUCTION & ELECTRIC LLC
ALTA MECHANICAL INC
ALTRUISTIC AIR INC
ALUFAB USA INC
ALUMINUM CONSTRUCTION SERVICES
ALUMINUM CONSTRUCTION SPECIALIST LLC
ALUMINUM DESIGN EXPERTS INC
ALUMINUM PLUS
ALUMINUM WORKS SHOWCASE SCREENS INC
ALVANNO ELECTRIC OF FL, LLC
ALVAREZ HOME REPAIRS
ALVAREZ ROOFING
ALVIN J SINGLETON INC
ALVIS CONSTRUCTION GROUP INC
ALVIS HEATING & COOLING INC
ALWAYS AIR HEATING AND COOLING
ALWAYS AIR SERVICES INC
AM ELECTRIC OF VENICE
AM ENGINEERING INC
AM EXTERIOR ALUMINUM, CO.
AM PM PLUMBING
AMA ELECTRIC PLLC
AMAE BUILDERS LLC
AMAZON AIR CONDITIONING INC
AMBIENT AIR INC
AMBIT ELECTRIC
AMBRO AIR LLC
AMC CONTRACTING INC
AMC MOBILE HOME MOVERS INSTALL
AMERICA ROOFING
AMERICA'S WINDOWS LLC
AMERICAN A/C SERVICES, LLC
AMERICAN BORING & TRENCHING INC
AMERICAN BUILDERS GROUP INC.
AMERICAN BUILDING CONTRACT INSURANCE RESTORATION
AMERICAN CLEANING & RESTORATION LLC
AMERICAN COMM CONSTRUC & DEVEL
AMERICAN DESIGN AIR INC
AMERICAN DISCOUNT A/C
AMERICAN DREAM BUILDERS OF SOUTHWEST FLORIDA INC
AMERICAN DREAM POOLS & SPAS LLC
AMERICAN EAGLE ALUMINUM INC
AMERICAN ELECTRICAL SVCS TAMPA
AMERICAN FIRE & SECURITY LLC
AMERICAN GENERAL CONSTRUCTION OF WEST FLA INC BATHS KITCHENS
AMERICAN GLAZIERS & SUPPLY
AMERICAN GRILL & HEARTH
AMERICAN HERO CONSTRUCTION, LLC
AMERICAN HOME CENTER INC
AMERICAN INTEGRITY CONSTR SVCS
AMERICAN IRRIGATION
AMERICAN LEISURE PLUS
AMERICAN PLUMBING OF SARASOTA
AMERICAN PLUMBING SERVICES OF FLORIDA INC
AMERICAN POWER SOLUTIONS
AMERICAN PRIDE ELECTRIC LLC
AMERICAN RESIDENTIAL SERV FL
AMERICAN RESIDENTIAL SOLUTIONS LLC
AMERICAN ROOFING & EXTERIORS
AMERICAN SIGN CO
AMERICAN SOLAR ENERGY LLC
AMERICOOL AIR SERVICE INC
AMERIGAS LP
AMERIGAS PROPANE, L.P. ( WILLIAM F. MOLLINS)
AMERITECH HOMES INC
AMEURO CONTRACTING & CONSULTING
AMICK ROOFING INC
AMJAK ENTERPRISES INC
AMK HOMES INC.
AMMESON ELECTRIC INC
AMPED AIR & HEAT LLC
AMPED POWER SERVICES LLC
AMPED SERVICES PLUS INC
AMPRO INC
AMS INC
AMTEL SOUTH INC
AMUSO ENTERPRISES INC
AN HONEST AC COMPANY LLC
ANCHOR AIR CONDITIONING INC
ANCHOR BAY BUILDERS LLC
ANCHOR CONSTRUCTION OF TAMPA
ANCHOR MOBILE HOME SERVICE LLC
ANCHOR ROOFING
ANCHOR SIGN INC
AND SERVICES (SRQ)
AND SERVICES (TPA)
ANDERSON AIR & ENERGY SOLUTION
ANDERSON BROTHERS, INC
ANDERSON DOCK AND LIFT CO
ANDERSON ELECTRIC SUPPLY INC
ANDERSON ENCLOSURES LLC
ANDERSON ENTERPRISES INC
ANDERSON SERVICE FOR HOME/BUS
ANDERSON WINDOW SERVICE INC
ANDERSON YORK
ANDORAN ROOFING LLC
ANDREW BELL INC
ANDREW LU ELECTRIC INC
ANDREW SITEWORK LLC
ANDREW'S PLUMBING INC
ANDREWS ROOFING LLC
ANECO ELECTRICAL CONSTRUCTION
ANGELS REMODELING & CONSTRUCTION LLC
ANGLERS CONTRACTING INC.
ANIMATED DISPLAY SYSTEMS INC
ANK AIR & HEAT INC.
ANKNEY GAS SERVICES INC
ANNOINTED AIR & REFRIGERATION
ANOTHER CHOICE SERVICES INC
ANOTHER QUALITY HOME STEVEN CARR INC
ANSCO & ASSOCIATES, LLC
ANTHONY & SYLVAN POOLS CORP
ANTHONY BEBBINGTON (OWNER BUILDER)
ANTHONY BENNETT DBA B&B FENCE SOLUTIONS
ANTHONY C LEONARD ENTERPRISES
ANTHONY CIRILLO ENTERPRISES
ANTHONY FIORE CONSTRUCTION INC
ANTHONY W GIRARD SPECIALTIES INC
ANTHONYS COOLING HEATING ELECTRICAL
ANYTIME CONSTRUCTION & ROOFING INC
AP CONSTRUCTION LLC
APC ROOFING, LLC
APEX ELECTRIC INC OF OHIO
APEX INSPECTIONS GROUP, INC.
APEX PLUMBING
APEX ROOFING AND RESTORATION LLC
APEX ROOFING CONTRACTORS LLC
APEX ROOFMASTERS INC
APG ELECTRIC INC
APPLE PLUMBING SERVICES
APPLE ROOFING FLORIDA
APPLE SIGN & AWNING, LLC
APPROVED ROOFING LLC
APTITUDE ASSOCIATES INC
AQUA CARE WATER TREATMENT & PLUMBING
AQUA DESIGNS & DECOR LLC
AQUA DOC POOL CLINIC LLC
AQUA DUCK PLUMBING LLC
AQUA PLUMBING & AIR SERVICES INC
AQUA SERVICES INC
AQUA-TECH PLUMBING CONTRACTORS INC
AQUASCAPES DESIGN INC
AQUATECH POOLS GC INC
AQUATIC DESIGN INC
AQUATIC INSPECTIONS LLC
AR FENCING AND GRADING INC
ARAC ROOF IT FORWARD LLC
ARAGON POOLS & SPAS LLC
ARBAS GROUP INC
ARC CONTRACTING LLC
ARC ELECTRIC OF FLORIDA LLC
ARC ELECTRICAL CONTRACTORS, INC.
ARCANE GROUP INC
ARCHER EXTERIORS, INC.
ARCHER WESTERN CONSTRUCTION, LLC
ARCHITECTURAL ALUMINUM & SCREENING
ARCHITECTURAL CONCEPTS INC
ARCHITECTURAL CONSTRUCTORS INC
ARCHITECTURAL GRAPHICS, INC.
ARCHITECTURAL SIGNS OF FL LLC
ARCHITECTURAL SPEC OF BREVARD
ARCON ROOFING
ARCTIC AIR DESOTO
ARCTIC AIR HOME SERVICES INC
ARCTIC AIR SERVICES INC
ARCTIC FOX COOLING INC
ARDACH MALATLIAN (INDIVIDUAL)
ARDENT ALUMINUM LLC
ARDURRA GROUP INC
AREA ELECTRIC INC
Ari's Mobile Home Installation & Repair, LLC
ARISTOCRAT PLUMBING INC
ARK CONTRACTORS INC
ARK ROOFING INC
ARLEY HOME SOLUTIONS, LLC
ARLIE REGINALD MCNEILL INC
ARLYN DESIGNS LLC
ARM ALUMINUM INC
ARM ELECTRIC LLC
ARMCOA LLC
ARMOR ALUMINUM LLC
ARMOR SYSTEMS AND SECURITY INC
ARMORED DADE WINDOWS & SHUTTERS
ARMORTECH WINDOWS AND DOORS INC
ARMORVUE OF SARASOTA LLC
ARMOUR ROOFING
ARMOUR ROOFING AND RESTORATION LLC
ARMSTRONG AIR & ELECTRIC, INC.
AROX LAND DEVELOPMENT CORP
ARQAI LLC
ARROW ALUMINUM INC
ARROW FENCE SYSTEMS
ARROW PLUMBING SERVICES LLC
ART KRAFT SIGN CO INC
ARTESIAN PLUMBING INC
ARTESIAN WELLS INC
ARTHUR O BRANNEN INC
ARTIC AIR OF ENGLEWOOD INC
ARTIC BREEZE AIR CONDITIONING CORP
ARTIC BREEZE ROOFING CORP
ARTIGAS PLUMBING INC
ARTISAN SIGNS INC
ARTISTIC DOORS & LOCKS INC
ARTISTIC PLUMBING CONCEPTS INC
ARTISTIC POOLS OF SARASOTA
ARTISTREE
ARTISTRY PAINTING COMPANY INC
ARZ BUILDERS, INC
AS CONTRACTING & DESIGN
ASAP ELECTRIC LLC
ASAP FENCE & GATES LLC
ASAP HEATING & COOLING INC
ASCEND WIRELESS NETWORKS INC
ASD SKY
ASGARD CONSTRUCTION LLC
ASHER KING SIGNATURE POOLS
ASHLEY BUILDERS INC
ASHSTONE INC
ASHTON ELECTRIC CO LLC
ASPEN CONTRACTING INC
ASPEN HOME IMPROVEMENTS
ASPER INC.
ASSA ABLOY ENTRANCE SYSTEM US INC
ASSIST 2 BUILD INC
ASSOC AIR SERV OF LEE CTY INC
ASSOCIATED AUTOMATIC SPRINKLER
ASSOCIATED CONSTR & DEVELOPMNT
ASSOCIATED PLUMBING INC
ASTON CONSTRUCTION CORP
ASURO CONSTRUCTION INC
AT YOUR SERVICE GAS PIPING
ATC GROUP SERVICES LLC DBA ATLAS
ATI RESTORATION LLC
ATKIN MARINE SERVICES
ATLANTIC KEY CONSTRUCTION
ATLANTIC KEY ENERGY, LLC
ATLANTIC SERVICE & SUPPLY
ATLANTIC SOUTHERN PAVING AND SEALCOATING LLC
ATLANTIS CONSTR & REMODELING
ATLANTIS CONSTRUCTORS OF SW FL
ATLANTIS HEATING & AIR INC
ATLANTIS POOLS & SPAS OF SRQ
ATLAS AIR COOLING & HEATING
ATLAS BUILDING CO OF FL, LLC
ATLAS FENCE COMPANY INC
ATLAS SIGNS HOLDINGS, INC
ATLAS SOLUTIONS INC
ATRIUM SHUTTERS INC
ATRIUM WINDOWS AND DOORS INC
ATTAWAY PARTNERS, LLC / SIGNARAMA
ATU CONTRACTING LLC
AUBURT WAYNE MCKINNON
AUDIO & COMMUNICATION EXPERTS INC
AUDIO VIDEO HELPERS LLC
AUE CONSTRUCTION GROUP LLC
AUGUST BUILDING & DEVELOPMENT
AUGUST ELECTRIC LLC
AURORA CONSTRUCTION AND DESIGN LLC
AURORA FIBER & COMMUNICATIONS CORP
AUTHENTIC AIR & HEAT INC
AUTOMATED LIFESTYLES INC
AUTUMN AIR CONDITIONING LLC
AVA CONSTRUCTION INC
AVAILABLE ROOFING INC
AVANT CONSTRUCTION, INC
AVATAR ROOFING CONTRACTOR
AVERY ROOF SERVICES LLC
AVILA CONSTRUCTION & GLAZING, INC
AW HUGHEY CONSTRUCTION SERVICE
AWESOME AIR INC
AWNING & SIGN CONTRACTORS
AWNING WORKS
AXEL WORKS, INC.
AYRES CONDITIONING LLC
AYUNIES CONSTRUCTION INC
AZ REMODELING & PLUMBING INC
AZTEC PLUMBING INC
AZTEK COMMUNICATIONS OF SOUTH FLORIDA INC
B & B PROFESSIONAL PLUMBING & AIR
B & B PROFESSIONAL PLUMBING & AIR
B & J HEATING AND AIR CONDITIONING, INC
B DESIGN LLC
B&B AWNINGS
B&B ELECTRICAL INNOVATIONS
B&B PROFESSIONAL PLUMBING
B&B SPARKY ELECTRIC SERVICE INC
B&D HEATING AND A/C
B&GS AIR CONDITIONING ELECTRICAL & SOLAR INC
B&H CONSTRUCTION OF CENTRAL FLA INC
B&I CONTRACTORS INC
B&J LININGS INC
B&K PLUMBING INC
B&L BUILDING CONTRACTOR INC
B&M CONCEPTS INC
B&M CONSTRUCTION CO INC
B&W ROOFING AND REPAIR LLC
BA ELECTRIC INC
BABES PLUMBING INC (FIRE)
BABES PLUMBING INC.
BACARR A/C & HEATING
BACH LAND DEVELOPMENT LLC
BACH SIGN LLC
BACKBAY ELECTRIC INC
BACKYARD RESORT STYLE POOLS
BACKYARD SOLUTIONS
BADGER BOB'S PLUMBING
BADGER BOB'S SERVICES LLC
BADGER BOBS ELECTRICAL
BADGER'S PLUMBING SERVICE INC
BAHIA CONSTRUCTION INC
BAHRS CONSTRUCTION LLC
BAILEY LAND CLEARING LLC
BAILEYS A/C & APPLIANCE REPAIR SERVICE LLC
BAILEYS POWER AND LIGHT ELECTRICAL SERVICES LLC
BAJA ELECTRIC SERVICE INC
BAKER & SONS AIR CONDITIONING
BAKER ALUMINUM LLC
BAKER, BRADFORD DENNIS-INDIVIDUAL
BAKER-SOUTH ROOFING COMPANY
BALAITY ELECTRIC INC
BALDWIN ROOFING COMPANY LLC
BALL CONSTRUCTION INC
BALLFER SERVICE CORP
BALLIET CUSTOM HOMES INC
BALSINGER POOL CONSTRUCTION & REMODEL LLC
BAMBOO BUILDING COMPANY LLC
BANKO OVERHEAD DOORS LLC
BANKS BROTHERS CONSTRUCTION
BANYAN BAY CORPORATION
BANYAN TREE CONSTRUCTION, LLC
BAR-TON SERVICES, LLC
BARATECH DYNAMICS LLC
BARBARA FAGER (OWNER BUILDER)
BARBAS BUILDING & DESIGNS INC
BARBOUR BUILDERS
BAREFOOT BAY BUILDERS INC
BARNARD BROS. ELECTRIC LLC
BARNES CONSTRUCTION
BARNES ELECTRIC OF CENTRAL FL
BARRACUDA ELECTRIC, LLC
BARRETT ELECTRIC, INC.
BARRETT'S QUALITY ELECTRIC LLC
BARRETTS ELECTRICAL SOLUTIONS
BARRIGER CONSTRUCTION GROUP, INC.
BARRUETA BUILDERS SWFL, CORP
BARTONS PROPANE SERVICE
BARWICK POOLS INC
BATES ELECTRIC INC
BATES ELECTRICAL CORP
BATH FITTER OF SOUTHWEST FL
BATH SOLUTIONS, ETC. INC
BATH-N-TILE PLUMBING DESIGN INC
Baths, Kitchens, and More
BATSON COOK COMPANY
BATTEN & SHAW INC
BAUER CONSTRUCTION GROUP INC
BAUMAN & SONS INC
BAVERS HEATING & AIR CONDITIONING INC
BAY AREA ELECTRIC & REFRIGERATION INC
BAY AREA ELECTRIC INC
BAY AREA L L ENTERPRISES INC
BAY AREA PLUMBING INC
BAY AREA REMODELERS INC
BAY AREA ROOFING INC
BAY BREEZE RESCREEN SALES & SERVICE LLC
BAY BRIDGE HOMES LLC
BAY FLORIDA BUILDERS, CORP
BAY MANUFACTURED HOMES INC
BAY POINT CONSTRUCTION INC
BAY TO BAY PROPERTIES LLC
BAYFRONT BUILDERS INC
BAYLIGHT CONSTRUCTION LLC
BAYLIS & BAYLIS INC
BAYONET PLUMBING HEATING & AIR-CONDITIONING LLC
BAYSHORE CONSTRUCTION INC
BAYSIDE DEVELOPMENT & CONSTRUCTION INC
BAYSIDE DREDGING LLC
BAYSIDE HEATING & COOLING
BAYSIDE RESTAURANT SERVICE INC
BAYSIDE ROOFING OF SW FL INC
BBMK CONTRACTING LLC
BC ELECTRIC INC
BCG CONTRACTING, LLC
BCH MECHANICAL LLC
BCI INTEGRATED SOLUTIONS
BCI INTEGRATED SOLUTIONS..
BCI POOLS INC
BCI TECHNOLOGIES INC
BDC CONSTRUCTION CORP
BEACH SERVICE ENTERPRISES INC
BEACHEM BROS ELECTRIC INC
BEACHSTREET BUILDERS INC
BEACON PLUMBING CO LLC
BEACON SOLAR ENERGY INC
BEANE STREET, LLC
BEAR HOME SERVICES INC
BEAR'S PLUMBING OF SO FL INC
BEAST AIR LLC
BEAU DAVIS ELECTRIC LLC
BEAVER ROOFING LLC
BECERRA CONSTRUCTION OF CENTRAL FLORIDA INC
BECK CONSTRUCTION LLC
BECKER INDUSTRIES GROUP LLC
BEE SURE HEATING & COOLING
BEECHWOOD BUILDERS INC
BEECHWOOD GREEN SOLUTIONS INC
BEEGREEN SOLAR LLC
BEEGREEN SOLAR, LLC
BEEMAN ELECTRIC INC
BEEMS CONSTRUCTION CO INC
BEILER CONSTRUCTION LLC
BEILER PREMIER ROOFING & CONST LLC
BELFOR USA GROUP INC
BELL & BELL CONSTRUCTION INC
BELL AIR LLC
BELL AIR LLC
BELL DESIGN OF SARASOTA, LLC
BELL SIGNS
BELLA DIFFERENZA CONSTRUCTION LLC
BELLEMARE TOTAL SYSTEMS INTEGRATION, LLC
BELLESSERE HOMES INC
BELLINGHAM MARINE
BELLMORE ELECTRIC INC
BELLUM CONSTRUCTION LLC
BEN DE JONG CUSTOM HOMES LLC
BENCHMARK ALUMINUM & CONSTRUCT
BENCHMARK ALUMINUM INC
BENCHMARK CONSTR OF SOUTH FLORIDA
BENCHMARK CONSTRUCTION MANAGEMENT LLC
BENCHMARK INNOVATIONS INC
BENCO CONTRACTORS GROUP CORP
BENEFICIAL FIRE PROTECTION INC
BENGT JIM STARING
BENJAMIN FRANKLIN PLUMBING
BENKO CONSTRUCTION CO INC
BENNETT AIR CONDITIONING OF VENICE LLC
BENNETT MARINE CONSTRUCTION INC
BENNY F WARREN MOBILE HOME SVC
BENSHOFF ELECTRIC INC
BENTLEY & SONS ELECTRIC INC
BENTLEY ROOFING, L.L.C.
BENTLEYS ALUMINUM AND HOME REPAIR INC
BENTZEL MECHANICAL INC
BERCHTOLD BUILDERS INC
BERKSHIRE BAY CONTRACTORS, INC.
BERLIN SIGN CO
BERYL PROJECT ENGINEERING & INSPECTION
BEST COAST BUILDERS
BEST ELECTRIC OF SARASOTA INC
BEST FUTURE HOMES INC
BEST HOME SERVICES
BEST LIGHTING ELECTRIC INC
BEST MODERN ELECTRIC LLC
BEST PLUMBING SERVICES COMPANY
BEST ROOFING TECHNOLOGY INC
BEST VALUE ROOFING
BETACOM INC
BEYOND AUDIO VISUAL
BEYOND DESIGN CONTRACTING LLC
BFAM BUILDERS, LLC
BFARR EXTERIORS, LLC
BFS
BG SOUTHERN DIVISION LLC
BGE INC
BHC TARGET LLC
BHL SERVICES INCORPORATED
BIANCHI'S CONSTRUCTION AND REMODELING L.L.C.
BIDLACK MARINE CONTRACTING
BIG BEAR HEATING & AIR LLC
BIG C ROOFING
BIG DADDY'S MOBILE HOME SET-UP SERVICE, LLC
BIG DOG CONSTRUCTION SERVICES
BIG KAHUNA TIKI HUTS INC
BIG SKY ELECTRIC LLC
BIG SUN FENCING
BIGFOOT COOLING AND HEATING, LLC
BIGFOOT ROOFING & CONSTRUCTION, INC.
BILL ISHERWOOD LLC
BILL JACK ROOFING COMPANY
BILL MILLER CONSTRUCTION MGMT
BILL PAPPAS CONSTRUCTION INC
BILL SLOCUM RESIDENTAL BLDR
BILL SLOCUM RESIDENTAL BLDR
BILL STANCEL MASONRY & CONCRET
BILL THE PLUMBER INC
BILL WALTHER CONSTRUCTION INC
BILL'S QUALITY AIR CONDITIONING
BILLY KIMBERLIN ROOFING INC
BINK INC
BIRCH'S AIR CONDITIONING & HEATING INC
BIRCHS A/C & HEATING INC
BIRD BUILDERS LLC
BIRD HOUSE BUILDING LLC
BIRDWELL ELECTRIC INC
BISHOP CONSTRUCTION SERVICES
BISHOP'S ALUMINUM SERVICES INC
BJ ELECTRICAL SERVICE LLC
BJ ENTERPRISES INC (FIRE)
BJ SIGNS
BKM ROOFING INC.
BKP ENTERPRISE INC
BLACK BELT PROPERTY PROTECTION LLC
BLACK DIAMOND ELECTRIC INC
BLACK DOG ELECTRICAL SERVICES
BLACK JACK AIR & MECHANICAL
BLACK OPS PLUMBING & SERVICES LLC
BLACK SPARK ELECTRIC LLC
BLACK TURTLE BUILDERS INC
BLACK WOLF HOLDINGS LLC
BLACKFOOT ELECTRIC CORPORATION
BLACKHAWK GENERAL SERVICE INC
BLACKJACK PLUMBING INC
BLACKWOLFF HOMES CONSTRUCTION
BLACO CONSTRUCTION INC
BLANTON CONTRACTOR SERVICES INC
BLANTON PLUMBING INC
BLAST AWAY DEMO
BLESSED ELECTRIC LLC
BLEVINS MOBILE HOME LLC
BLISS PRODUCTS AND SERVICES INC
BLITZ ROOFING & CONSTRUCTION LLC
BLIZZARD CONDITIONS AIR & HEAT LLC
BLONDIN ELECTRIC INC
BLOODSWORTH CONTRACTING LLC
BLR CONSTRUCTION SERVICE INC
BLU AQUA POOLS CORPORATION
BLUE BEAR HEATING & AIR LLC
BLUE BREEZE HEATING & A/C CORP
BLUE DOLPHIN PLUMBING INC
BLUE ESSENCE POOLS LLC
BLUE HAVEN POOLS
BLUE HAVEN POOLS OF FT MYERS
BLUE HERON POOLS OF FLORIDA, INC.
BLUE JAY AIR CONDITIONING AND HEATING LLC
BLUE OCEAN MECHANICAL SERVICES, LLC
BLUE RIBBON PLUMBING SERVICE
BLUE RUNNER CONSTRUCTION LLC
BLUE SKY CONST MANAGEMENT INC
BLUE SKY ROOFING LLC
BLUE SKY SOLAR ENERGY
BLUE WATER CUSTOM HOMES INC.
BLUE WAVE AIR LLC
BLUEFIN MECHANICAL LLC
BLUEHAVEN BUILDERS, LLC
BLUELINE MECHANICAL
BLUENERGY LLC
BLUENERGY ROOFING LLC
BLUETEAM ROOFING LLC
BLUEWATER TELECOMMUNICATIONS INC
BLUEWIRE ELECTRICAL SERVICES
BLUSCAPE HOMES
BLUSKY RESTORATION CONTRACTORS, LLC
BLUSPARK ELECTRICAL CONTRACTING INC
BLUWATER POOL DESIGN LLC
BMCI CONTRACTING INC
BMI LLC
BMS CAT INC
BNT BUILDING AND REMODELING, LLC
BO'S ELECTRIC INC.
BOARDWALK PROPERTIES, INC.
BOB ANDERSON PLUMBING
BOB FINK ELECTRIC INC.
BOB GOUGE CONSTRUCTION LLC
BOB LEE ELECTRIC INC
BOB LETTERMAN PLUMBING INC
BOB MARKS PLUMBING INC
BOB MILLER MASONRY, INC
BOB MYERS & SONS INC
BOB'S CONSTRUCTION SERVICES
BOB'S ELECTRIC INC
BOGARTS HOME IMPROVEMENTS
BOGEY'S CONTRACTING LLC
BOHALL'S TOTAL COMFORT INC
BOLD ROOFING, INC
BOLT ELECTRIC
BOLT POWER LLC
BOMAC ELECTRIC
BONDED POOLS INC
BONE DRY ROOFING FLORIDA INC
BONES HOME SERVICES LLC
BONNER ROOFING LLC
BONTRAGER MASONRY INC
BONTRAGER ROOFING INC
BOOTH ELECTRIC
BOOTZ PLUMBING INC
BORAN CRAIG BARBER ENGEL CONST
BORNTREGER ALUMINUM INC
BORNTREGER PROTECTIVE SOLUTION
BOSCH BROTHERS AIR CONDITIONING CORP
BOSTON ELECTRIC LLC
BOTTOM LINE CONSTR MANAGEMENT
BOWERSOX AIR CONDITIONING AND HEATING LLC
BOWMAN CONSULTING GROUP
BOY'S PLUMBING INC
BOYD BROTHERS SERVICE INC
BOYETTE & MILLER CONST/ DEVELOPMENT INC
BOYLE'S ALUMINUM AND SCREENING LLC
BOZENA HOMES INC
BPL VENTURES LLC
BPS COASTAL CONSTRUTION LLC
BRACKENS ELECTRIC INC
BRAD HARTT CONSTRUCTION LLC
BRAD HILL CONSTRUCTION INC
BRAD TOTTEN CARPENTRY INC
BRADANNA INC
BRADENTON BUILDING SERVICES INC
BRADENTON COOLING & HEATING
BRADENTON ELECTRICAL SERVICE
BRADENTON PLUMBING
BRADY CONTRACTING INC
BRANCHING OUT, INC
BRANDEN RIVER CONSTRUCTORS INC
BRANDES DESIGN BUILD INC
BRANDON ELECTIRIC
BRANT CONSTRUCTION MGMT INC
BRASFIELD & GORRIE LLC
BRAVADO PLUMBING LLC
BRC RESTORATION
BREAKWATER CONSTRUCTION LLC
BREED CONTRACTING & LOGISTICS
BREGO CONSTRUCTION CORP
BRETT R MARKLEY CONSTRUCTION
BRETTE ANSPACH CONCRETE INC
BRI-GON HOMES LLC
BRIAN BOWERSOX INC
BRIAN C BISHOP
BRIAN O'DONNELL CONSTRUCTION
BRIAN ZAMBRANO AND ASSOCIATES INC.
BRICK CITY PLUMBING LLC
BRIDGES ELECTRIC INC
Brigham Allen Land Surveying
BRIGHT FUTURE ELECTRIC LLC
BRIGHT LIGHT ELECTRICAL SOLUTIONS LLC
BRIGHT STAR ELECTRIC LLC
BRIGHTVIEW LANDSCAPING
BRILLANT HARVEST LLC
BRILLIANT HARVEST LLC
BRINGMAN ROOFING COMPANY
BRINK CONSTRUCTORS INC
BRINK ELECTRIC INC
BRISK AIR CONDITIONING LLC
BRISTA HOMES INC
BRITE IDEAS ELECTRIC LLC
BRITTANIA CUSTOM HOMES LLC
BRIZO CONSTRUCTION LLC
BROADVIEW SECURITY INC
BROCK HOME LLC.
BROOKS & FREUND LLC
BROOKS & FREUND LLC
BROOKS BROTHER ELECTRICAL, INC
BROOKS SEPTIC & PLUMBING
BROWARD FACTORY SERVICE
BROWER, JESSE LEE DBA PLUMBPRETTY LLC
BROWN & BROWN RESIDENTIAL BLDG
BROWN HEATING AND COOLING INC
BROWN'S A/C INC
BROWN'S ELECTRIC OF CENTRAL FL
BROWN'S PLUMBING SERVICES INC
BROWN'S TREE SERVICE
BROWNING HEATING AND AIR LLC
BROWNS AC INC
BRUCE D LADD CO
BRUCE D LADD PLUMBING CONT CO
BRUCE HENGST ROOFING
BRUCE HERING HOMES INC
BRUNDERMAN BUILDING CO INC
BRUNNER AIR CONDITIONING INC
BRUNO AIR CONDITIONING OF SWFL
BRUSSEE ELECTRIC LLC
BRYANS ELECTRICAL SERVICES
BRYANT ROOFING LLC
BRYANT SAMUEL ENTERPRISES, INC
BRYCONIAN ENTERPRISES INC
BT MCCARTHY INC
BTAN INC
BTNH ADVISORS LLC
BUCKHALTER HOMES INC
BUILD ALL INC
BUILDCO OF SOUTHWEST FL INC
BUILDERS OF DISTINCTION
BUILDERS SPECIALTIES OF VENICE
BUILDING AIR SERVICES HVAC INC
BUILDING CODE COMPLIANCE SOLUTIONS, LLC
BUILTRUE CONSTRUCTION CORP
BUILTRY, INC
BULLDOG POOLS
BULLOCK CONSTRUCTION LLC
BULLSEYE HOME SERVICES
BUNDSCHU KRAFT INC
BURES COMPANIES INC
BURGESS SIGNS INC
BURKE CONSTRUCTION GROUP INC
BURNAM'S HOME IMPROVEMENT
BURNS INSTAR SERVICES GROUP
BURR & TIEGS ELECTRIC
BUSY BEE SEPTIC INC
BUTLER PAVERS INC
BV ELECTRIC INC
BV ELECTRIC INC
BWM 1 INC
C E A BUILDERS CORP
C MARTIN CONSTRUCTION INC
C&C ELECTRICAL CONTRACTORS INC
C&C MOBILE SETUP & SERVICE
C&C SERVICES OF TAMPA INC
C&J ALUMINUM INC
C&J ROOFING OF CHARLOTTE CTY
C&M TOTAL RENOVATIONS
C&N RENOVATION INC
C&S HEATING & COOLING COMPANY
C&S HEATING AND COOLING LLC
C&S ROOFING COMPANY
C&S SIGNS LLC
C+R REMODELING AND CONSTRUCTION
C-SQUARED CERT GENERAL CONTR
C-SQUARED CONSTRUCTION MANAGEMENT LLC
C. JACKSON ELECTRIC, INC.
C.O. CONSTRUCTION, INC
C2C RESTORATION LLC
C2G TEST CONSTRUCTION INC
CABINET DESIGN STUDIO INC
CABINETREE KITCHEN & BATH DESI
CABINETS EXTRAORDINAIRE INC
CABLE ELECTRICAL SERVICES INC.
CABRERA JACH MULTISERVICE, INC
CADEN GENERAL CONTRACTORS LLC
CADSTRUCT CORP
CADTRONI ELECTRICAL SOLUTIONS
CAGESMITH ENCLOSURES LLC
CAHILL & CHLEBINA BLDG CONTR
CAIBAI CONSTRUCTION LLC
CAITHNESS CONSTRUCTION INC
CALEXIS POOLS INC
CALI-MCGINNIS CONTRACTORS
CALIBER ELECTRIC LLC
CALKINS PROPANE INC
CALL CANDY
CALUSA ELECTRIC INC
CAM CONNECTIONS INC
CAM CONSTRUCTION SERVICES INC
CAM PLUMBING OF FLORIDA, LLC
CAM TOTAL SERVICE OF FLORIDA LLC
CAMILLE TANNER
CAMINO PALMS CONSTRUCTION AND PROPERTIES INC
CAMLIN HOMES CORPORATION
CAMP CONSTRUCTION SERVICES
CAMP-RIGBY MANGEMENT INC
CAMPBELL ROOFING & SHEET METAL
CAMPOPIANO ROOFING LLC
CAMPOS FAMILY CONSTRUCTION INC.
CAMPOS, GABRIELLE ESTELADYS
CANADAY COOLING & HEATING
CANDATT INC
CANDLELITE ELECTRICAL SERVICE
CANDOUR CONSTRUCTION, LLC
CANINO CONSTRUCTION INC
CANOPY SPECIALIST LLC
CAPE CORAL SCREEN & VINYL
CAPE HAZE ROOF PRO LLC
CAPE SHORE PLUMBING & SERVICES INC
CAPITAL CONSTRUCTION FIRM, INC
CAPITAL ROOFING & SHEET METAL
CAPITOL BUSINESS EQUIPMENT, INC.
CAPSTONE CG LLC
CAPSTONE CONTRACTORS, LLC
CAPTAIN COOL LLC
CAPTIVA COOLING INC
CARDINAL CONTRACTORS INC
CARDINAL ROOFING & SIDING CO
CARE ELECTRIC INC
CARLISLE PAINTING & CONSTRUCT
CARLL BURR HOMES LLP
CARLOS MARTINEZ ELECTRIC LLC
CARLTON & GRAHAM RETAIL CONSTR
Carlton J Hurt Trust
CAROLINA CARPORTS INC
CARPENTER HEATING-COOLING LLC
CARPENTRY BY GUS INC
CARPORTS ANYWHERE INC
CARRANZA CONSTRUCTION INC
CARRIER CORPORATION
CARTWRIGHT ELECTRIC LLC
CAS CONSTRUCTION LLC
CASA POOLS
CASEY'S PLUMBING INC
CASIQUE FENCE INSTALLATION & REPAIR
CASSATA PROPERTIES, LLC
CASTELLI CONSTRUCTION LLC
CASTELLON PLUMBING CORP
CASTLE AIR
CASTLE CONSTRUCTION OF SW FL
CASTLE HOME BUILDERS, LLC
CASTLE ROOFING & CONSTRUCTION, INC.
CASTLEBROOK RESTORATION & ROOFING
CASTO SOUTHEAST REALTY, LLC
CASUAL HOMES INC
CAT 5 HURRICANE PRODUCTS LLC
CATALINA CONSTRUCTION INC
CAVOLI ENGINEERING INC
CAWLEY CONSTRUCTION CORP
CB ROOFING CONSTRUCTION INC
CB SIGN SERVICE INC
CBE CONSTRUCTION
CBJ BUILDERS GROUP INCORPORATED
CBS ROOFING AND WATERPROOFING INC
CCA ROOFING CORP
CCI SYSTEM INC
CCS CABINET DESIGNS LLC
CCS OF SARASOTA INC
CE HUFFMAN TRUCKING INC
CENTAUR ROOFING & CONSTRUCTION LLC
CENTER STATE ELECTRIC INC
CENTERLINE CONSTRUCTION & CO
CENTERLINE SOLUTIONS
CENTIMARK CORPORATION
CENTRAL AIRE CONDITIONING INC
CENTRAL DOZER SERVICE
CENTRAL FIRE
CENTRAL FIRE & SAFETY EQUIPMENT INC
CENTRAL FLORIDA FIRE PROTECT
CENTRAL FLORIDA GLASS
CENTRAL FLORIDA ROOFING
CENTRAL MAINTENANCE & WELDING
CENTRAL SERVICES WEST TREE & L
CENTRAL SYSTEMS & SECURITY SVC
CENTURY FIRE PROTECTION
CENTURY FIRE PROTECTION LLC
CENTURY HEATING & AIR CONDITIONING INC
CENTURY ROOFING SPECIALISTS LLC
CEP ELECTRIC LLC
CERTAIN SERVICES, INC
CERTI-PRO INC
CERTIFIED BUILDING CONTRACTORS OF FLORIDA LLC
CERTIFIED FOUNDATIONS INC
CERTIFIED MULTIMEDIA SOLUTIONS LLC
CERTIFIED POOL MECHANICS 1 INC
CERTIFIED POOL MECHANICS INC
CERTIFIED ROOFING SOLUTIONS, LLC
CERTIFIED ROOFING SPECIALISTS INC
CES COMMERCIAL ROOFING, LLC
CESO, INC.
CFS MECHANICAL SERVICES, LLC
CFS ROOFING SERVICES, LLC
CGC HOMES INC
CGC59126
CGM SERVICES
CH CONSTRUCTION SERVICES INC
CHAD OHARAS QUALITY ELECTRICAL SERVICES INC
CHAPMAN CONCRETE CONTRACTING
CHAPMAN PLUMBING LLC
CHAPPELLE ROOFING LLC
CHARGEPROS
CHARLES A ROY ROOFING INC
CHARLES E LINDSEY LLC
CHARLES H WILSON CONSTRUCTION
CHARLES HAGER CONSTRUCTION INC
CHARLES M WATTS AIR CONDITIONI
CHARLES PERRY CONSTRUCTION INC
CHARLIE BROWN'S HAULING & DEMO
CHARLIE CRAIG & ASSOCIATES LLC
CHARLIE RICE ROOFING, INC.
CHARLIES CONSTRUCTION COMPANY INC
CHARLOTTE COUNTY SEAWALLS INC
CHARLOTTE HARBOR HOMES INC
CHARLOTTE PLUMBING
CHARLOTTE PREMIUM ELECTRIC INC
CHARLOTTE SHEET METAL & FABRIC
CHARLOTTE SHEET METAL FABRICAT
CHESTER A ROBBINS
CHICK'S CUSTOM STUCCO LLC
CHIMNEY CRICKET
CHOICE ELECTRICAL, INC
CHR.ST.AL CONSTRUCTION INC
CHRIS MATRAS ENTERPRISES INC
CHRIS MATTHEWS CONSTRUCTION INC
CHRIS SMITH CONTRACTING SVCS
CHRIS W ROADS LLC
CHRIS-TEL CONSTRUCTION
CHRISTIANO CONSTRUCTION CO
CHRISTIE'S PLUMBING COMPANY
CHRISTOPHER M EGOLF CONSTRUCTI
CIA ACCESS
CICCARONE & CICCARONE INC
CIMMINO BROTHERS LLC
CINTAS CORP #2 / CINTAS FIRE PROTECTION
CINTAS FIRE PROTECTION
CIRCLE A ENTERPRISES
CIRCLE L ROOFING INC
CIRCLE M A/C & HEATING INC
CIRCLE PLUMBING INC
CIRCUIT ELECTRIC SERVICES INC
CIRCUIT SOLUTIONS LLC
CIRILLO ELECTRIC
CIRSCO COMMERICAL INDUSTRIAL
CITRUS CONTRACTING
CITRUS PLUMBING OF VENICE INC
City of Venice
City of Venice
City of Venice
CITY OF VENICE UTILITIES DEPARTMENT
CJ'S LLC
CJ'S LLC
CJ'S SALES & SERVICE OF OCALA
CK CONSTRUCTION INC
CL AIR SOLUTIONS LLC
CLANCY & THEY'S CONSTRUCTION CO
CLARITY AIR COND HEATING INC
CLARK DEVELOPMENT INC
CLARKE ELECTRICAL SERVICES INC
CLASS A CONTRACTING INC
CLASSIC ALUMINUM RESCREEN
CLASSIC BUILDING DESIGNS LLC
CLASSIC CONSTRUCTION LTD CO
CLASSIC POOL SERVICES
CLAUDIN ALTIDOR
CLAWSON PLUMBING INC
CLAXTON ELECTRIC INC
CLAY KOHLMEYER GENERAL CONTR
CLAY'S PLUMBING SERVICE INC
CLEAN INITIATIVE
CLEAR CHOICE WINDOWS & MORE INC
CLEAR PATH INDUSTRIES LLC
CLEAR TECH INC
CLEAR VIEW GLASS
CLEAR-WATER & AIR LLC
CLEARVIEW LAND DESIGN PL
CLEARVIEW WINDOWS AND DOORS INC
CLEARWATER SHOWER BATH LLC
CLEARY ELECTRIC INC
CLEM'S ELECTRIC COMPANY
CLEMENT ELECTRIC INC
CLIF BETTS HEATING COOLING REF
CLIFFS AIR CONDITIONING & HEATING INC
CLIFTON CONSOLIDATED CORP FL
CLIMATE DESIGN A/C (ERNEST)
CLIMATE DESIGN A/C (THOMAS)
CLIMATE SOLUTIONS INC
CLIMATIC CONDITIONING CO INC
CLINE ROOFING SERVICES INC
CLINTON CORPORATION
CLOSE CONSTRUCTION SERVICES LLC
CLS CONSTRUCTION
CMC CONSTRUCTION SOLUTIONS LLC
CMC OPERATIONS, INC
CMM COMMERCIAL CONTRACTORS INC
CMM ROOFING
CMR CONSTRUCTION & ROOFING LLC
CMR FL SOLUTIONS LLC
CMS MECHANICAL SERVICES LLC
COACHMAN HOMES INC
COARSEY PLUMBING SERVICES LLC
COAST 2 COAST CONSTRUCTION
COAST CONSTRUCTION GROUP LLC
COAST PLUMBING & UTILITIES
COAST TO COAST FIRE PROTECTION
COAST TO COAST POOLS INC
COASTAL AIR & REFRIGERATION
COASTAL AIR AUTHORITY INC
COASTAL AIR COOLING & HEATING
COASTAL AIR INC
COASTAL AUDIO VIDEO INC
COASTAL BREEZE GARAGE DOORS LLC
COASTAL BUILDING COMPANY INC
COASTAL CANVAS AND AWNING CO INC
COASTAL CODE SERVICES INC
COASTAL CONCRETE PRODUCTS INC
COASTAL CONSTRUCTION AND ASSOCIATES, LLC
COASTAL CONSTRUCTION AND REMODELING
COASTAL CONSTRUCTION GROUP
COASTAL CONSTRUCTION RESTORATION LLC
COASTAL CUSTOM CONSTRUCTION
COASTAL ELECTRIC SOLUTIONS LLC
COASTAL ENERGY
COASTAL FIRE PROTECTION, INC
COASTAL GREEN ENERGY SOLUTIONS, LLC
COASTAL HOME CONSTRUCTION LLC
COASTAL LIVING KITCHEN & BATH
COASTAL MARINE CONSTRUCT INC
COASTAL MECHANICAL SERVICES LLC
COASTAL METAL LLC
COASTAL MITIGATIONS INC
COASTAL PLUMBING & MECHANICAL
COASTAL PLUMBING OF SW FL LLC
COASTAL POOLS & MORE
COASTAL PRO ROOFING
COASTAL PROPERTY GROUP OF FL INC
COASTAL RECONSTRUCTION GROUP
COASTAL ROOFING
COASTAL SECURITY SYSTEMS
COASTAL SIGN INSTALLATION LLC
COASTAL STORM PROTECTION INC
COASTLINE CONTRACTORS, LLC
COASTLINE COOLING LLC
COASTLINE KITCHEN & BATH
COASTLINE ROOFING COMPANY LLC
COATUE CONSTRUCTION & DEVELOPMENT
COBB ROOFING INC
COCHRAN FIRE PROTECTION INC
COCONUT WALK ESTATES INC
COCOZZA CONSTRUCTION & CONSULT
CODE CONSTRUCTION
CODE ENGINEERED SYSTEMS INC
CODE RED FIRE PROTECTION INC
CODE RED PLUMBING INC
COGBURN BROS INC
COGGINS PLUMBING INC
COGS MECHANICAL
COLD FRONT COOLING OF SWFL INC
COLDSTREAM EXTERIORS TAMPA LLC
COLE ELECTRIC OF SARASOTA INC
COLLETT SOUTH PLUMBING INC
COLLIER ELECTRIC COMPANY INC
COLLIER ELECTRIC COMPANY OF FT MYERS INC
COLLIER SAFE COMPANY INC
COLLINS ELECTRIC COMPANY INC
COLLIS CONTRACTING INC
COLLIS ROOFING INC
COLONIAL GENERATORS
COLONIAL ROOFING INC
COLTZ CONSTRUCTION LLC
COLWILL ENGINEERING DESIGN BLD
COM FLA CONTRACTORS CO
COMCAST (BP TRUENET COMMUNICATIONS INC)
COMCAST BUSINESS SMARTOFFICE
COMEAU CONSTRUCTION
COMFORT AIR SYSTEMS INC.
COMFORT COVER SYSTEMS INC
COMFORT ROOFING INC
COMFORT SYSTEMS USA SOUTHEAST
COMFORT TECHNOLOGIES INC
COMFORT TEMP LLC
COMFORT ZONE A/C & ELECTRIC
COMMAND AIR LLC
COMMAND CONSTRUCTION INC
COMMERCIAL AIR & REFRIGERATION
COMMERCIAL COATING PROS OF FL
COMMERCIAL CONCRETE SOLUTIONS, LLC
COMMERCIAL ELECTRICAL SYSTEMS
COMMERCIAL ENERGY SYSTEMS
COMMERCIAL FENCE CONTRACTORS
COMMERCIAL FIRE COMMUNICATIONS
COMMERCIAL INSTALLATION AND CONSTRUCTION COMPANY
COMMERCIAL INSTALLATION AND CONSTRUCTION COMPANY
COMMERCIAL MAINTENANCE SYSTEMS
COMMERCIAL RESIDENTIAL ALUMINUM & FABRICATING LLC
COMMERCIAL ROOFING CONCEPTS
COMMODORE'S HEATING & A/C
COMMONS MEDICAL DEVELOPMENT
COMMUNITY ROOFING OF FLORIDA INC
COMPASS BUILDING SERVICES,INC.
COMPASS ROOFING SERVICES INC
COMPLETE ACCESS PLUMBING LLC
COMPLETE ALUMINUM GENERAL CONTRACTORS INC
COMPLETE BUILDING SOLUTIONS LLC
COMPLETE CIRCUIT ELECTRIC LLC
COMPLETE COMFORT SERVICES
COMPLETE POOL RENOVATIONS INC
COMPLETE ROOFING SOLUTIONS OF FLORIDA LLC
COMPLETE WIRING INC
COMPREHENSIVE ENERGY SERVICES INC
COMPUTER POWER SYSTEMS
COMSTRUCT SERVICES INC
CONCH ELECTRIC INC
CONCRETE MASTERS
CONCRETE PAINTING AND RESTORATION LLC
CONCRETE PROTECTION AND RESTORATION LLC
CONDITIONED AIR COMPANY OF NAPLES LLC
CONDOR ROOFING & SHEETMETAL
CONFIDENT COOLING
CONINMAQ LLC
CONNECT CABLING
CONNERY BUILDS LLC
CONNORS HOME REPAIR
CONNORS REMODELING AND HOME REPAIR INC
CONSERV BUILDING SERVICES
CONSERVA IRRIGATION OF SW FL
CONSOLIDATED HEATING & A/C INC
CONSTR SERVICES BY WALT FISHER
CONSTRUCT 4 U, LLC
CONSTRUCTION CLASSICS LLC
CONSTRUCTION DIMENSIONS INC
CONSTRUCTION FABRICATION SERVICES
CONSTRUCTION GENES LLC
CONSTRUCTION ON DEMAND
CONSTRUCTION PROJECT PROS, LLC
CONSTRUCTION SERVICES MANASOTA
CONSTRUCTION SOLUTION LLC
CONSTRUCTION SOLUTIONS INTERNATIONAL INC
CONSTRUCTIVE CONCRETE LLC
CONSTRUCTIVE RESOURCE INC
CONSTRUCTOMAX CORPORATION
CONTEMPORARY COASTAL BUILDERS LLC
CONTINEO GROUP
CONTRACTING SERVICES OF VENICE LLC
CONTRACTOR FOR CHRIST LLC
CONTRACTOR PLUS INC
CONTRACTOR'S GROUP LLC
CONTRACTORS CHOICE OF MS INC DBA CLOSE, DAN
CONTRACTORS SOLUTIONS GROUP
CONTROL ELECTRIC LLC
CONTROL TECHNOLOGIES SOUTH LLC
CONTROLLED TEMP INC
CONVENT ELECTRIC SERVICE CO
CONWAY ROOFING COMPANY
COOK'S MOBILE HOME REPAIRS & SERVICES
COOL ALTERNATIVES INC
COOL CLEAN AIR, LLC
COOL COAST HEATING & COOLING
COOL CONCEPTS HEATING & COOL
COOL DOWN AIR CONDITIONING LLC
COOL POOL PROS
COOL TECH INC
COOL TODAY
COOL WORKS HEATING & COOLING
COOLAIR CONDITIONING INC
COOLENHEAT INC
COOLING DYNAMICS AIR & REFRIG
COOLING DYNAMICS REFRIGERATION
COOPERS STEEL FABRICATORS INC
COPELAND'S COMPLETE CONSTRUCTION, LLC
COPELANDS COMPLETE CONSTRUCTION LLC
COPPER'S ROOFING INC
CORAL COAST CONSTRUCTION OF SOUTHWEST FLORIDA INC
CORAL COVE CONSTRUCTION INC
CORAL SANDS CONSTRUCTION LLC
CORBETT FIRE PROTECTION INC
CORE CONSTRUCTION SERV OF FLA
CORKINS CONSTRUCTION LLC
CORNERSTONE BLDG & REMODELING
CORNERSTONE BUILDERS OF SW FLORIDA INC
CORNERSTONE REPL WINDOWS
CORNERSTONE RESTORATION LIMITED LIABILITY COMPANY
CORONADO CUSTOM HOMES INC
CORP CONSTRUCTION
CORSO AIR SERVICES, LLC
CORTEZ HEATING & AIR COND
CORY C CLARK LANDSCAPES LLC
COSENTINO CONSTRUCTION CO
COUGAR CONTRACTING LLC
COUGAR CONTRACTING LLC
COUGAR CUTTING INC
COUNTRYSIDE GLASS & MIRROR INC
COUNTRYSIDE PLUMBING INC
COUNTS ELECTRIC INC
COUNTY PLUMBING CO OF VENICE
COUNTY PLUMBING SERVICES INC
COURTOY ELECTRIC
COV_TEST
COVENANT HOMES INC
COVENANT ROOFING & CONSTRUCTION INC
COWART ELECTRICAL & INDUSTRIAL CONTRACTORS INC
COX ELECTRIC
COX FIRE PROTECTION INC
COX FIRE PROTECTION, INC
COX HEATING & AIR CONDITIONING
COXEY CONSTRUCTION LLC
COZY CLIMATE, LLC
COZY COOLING & HEATING LLC
CP CUSTOM AIR LLC
CP DANNER CONSTRUCTION INC
CR & SONS CONTRACTORS INC
CRAFT PLUMBING SERVICES LLC
CRAFTSMAN CUSTOM BUILDERS, LLC
CRAFTSMAN ROOFING & RESTORATION LLC
CRAIG CONSTRUCTION INC
CRAIG PYNN CUSTOM METAL ROOF
CRAIG YOUNG CONSTRUCTION INC
CRANE GENERAL CONSTRUCTION INC
CRANNIE SIGNS INC / DBA SIGNS BY CRANNIE
CRANNIE SIGNS INC DBA SIGNS BY
CRE ZONING
CREATIVE CONSTRUCTION USA INC
CREATIVE CONTRACTING SOLUTIONS
CREATIVE CONTRACTORS INC
CREATIVE COUNTER FABRICATION
CREATIVE ELECTRIC SERVICES LLC
CREATIVE LADY REMODELING
CREATIVE ROOFING CORP.
CREATIVE SIGN DESIGNS
CREEKMORE CONSTRUCTION OF FLORIDA INC
CREIGHTON CONSTRUCTION & MANAGEMENT LLC
CREST ENGINEERING OF SARASOTA LLC
CREVELLO ELECTRIC INC
CREW CONNECT USA LLC
CRISP PLUMBING INC
CRISTIANO ELECTRIC INC
CRITICAL SYSTEM SOLUTIONS
CRM SOUTH ROOFING SOLUTIONS
CROM LLC
CROSS CONSTRUCTION SERVICES
CROSS ENVIRONMENTAL SERVICES
CROWLEY SERVICES INC
CROWN CASTLE USA INC
CROWN DESIGN GROUP LLC
CROWN RESIDENTIAL SERVICES LLC
CROWN ROOFING & WATERPROOFING LLC
CROWN ROOFING LLC
CROWTHER ROOFING AND SHEET METAL OF FLORIDA INC
CRS BUILDING CORPORATION
CRUZ PLUMBING INC
CRW Test Contractor
CRYSTAL CLEAR POOL SERVIC
CRYSTAL CONSTR OF POLK COUNTY
CRYSTAL SHUTTERS
CS OF VENICE DEVELOPMENT COMPANY LLC
CSC
CSI COMMUNICATIONS INC
CSI RENOVATIONS AND ROOFING OF FL
CSS AIR CONDITIONING
CT EARLE CORPORATION
CT ELECTRICAL SOLUTIONS, INC
CT FIRE PROTECTION INC
CT POWER AND CONTROLS INC.
CT SOLUTIONS OF FLORIDA LLC
CTM RESTORATIONS INC
CU PLUMBING INC
CUHACI & PETERSON ARCHITECTS
CULVER ALUMINUM PRODUCTS
CURB SYSTEMS OF SW FL AND SARASOTA LLC
CURRENT BUILDERS OF FL INC
CURRENT ELECTRIC OF SW FLORIDA LLC
CURRENT VOLTAGE, LLC
CURRIER ROOFING CO INC
CURTIS JORDAN CONSTRUCTION
CUSTOM AIR AND PLUMBING
CUSTOM AIR INC
CUSTOM BUILDING PROFESSIONALS
CUSTOM CABLE
CUSTOM CLIMATE CONCEPTS INC
CUSTOM COOLING & HEATING INC
CUSTOM CURRENTS ELECTRIC
CUSTOM DOCK & DAVIT
CUSTOM DOCK & DAVIT INC
CUSTOM DRYWALL CONSTRUCTION CO
CUSTOM ELECTRICAL CONTRACTORS
CUSTOM ELECTRICAL INC
CUSTOM ELECTRICAL SYSTEMS INC
CUSTOM HOMES & REMODELING
CUSTOM HOMES AND REMODELING
CUSTOM POOLS BY PRECISION INC
CUSTOM ROOFING SYSTEMS INC
CW HABER INC
CW HAYES CONSTRUCTION CO
CW PHILLIPS CONSTRUCTION LLC
CW'S QUALITY ROOFING INC
CY BLUE PLUMBING INC
CYNERGY ELECTRICAL LLC
CYPRESS COMMUNICATIONS INC
CYPRESS PLUMBING
CYPRESS SIGNS
CZR ROOFING INC
D & J ROOFING AND CONSTRUCTION INC
D GARRETT CONSTRUCTION INC
D M CONSTRUCTION CORPORATION
D PECK ROOFING INC
D SALADINO CONSTRUCTION LLC
D SCOLARO ALUMINUM & WINDOWS
D&C AIR AND HEAT INC
D&D AIR CONDITIONING INC
D&D AWNINGS LLC
D&D CONTRACTORS OF FL INC
D&D GARAGE DOORS INC
D&D PAINTING AND RESTORATION LLC
D&D WINDOW SOLUTIONS, LLC
D&M ELECTRICAL SERVICES LLC
D&R ELECTRICAL SERVICES
D&W HEATING & AIR CONDITIONING
D&W PROPERTY DEVELOPMENT INC
D. MARTIN PLUMBING INC
D2 BUILDERS INC
DA SIGNS ENTERPRISES INC
DAD'S DOOR AND WINDOW INC
DAGASA INC
DAILEY BUILDERS INC
DALE A BROWN CONSTRUCTION INC
DALE JAMES MASONRY INC
DALE'S AIR & HEAT INC
DALE'S ROOFING LLC
DALES AIR CONDITIONING HEATING
DAMM GOOD PLUMBING & AIR CORPORATION
DAN MCKENZIE (OWNER BUILDER)
DAN RUTKOWSKI CONSTRUCTION INC
DAN WELLINS ELECTRIC
DANA HEATING AND AIR CONDITION
DANDREA ELECTRIC INC
DANELLA CONSTRUCTION CORPORATION OF FL INC
DANIEL K CUMMINGS ROOFING
DANIEL MOSSEY CONSTRUCTION INC
DANIEL RATZ LLC
DANIELLE FENCE MANUFACTURING CO INC
DANIELS PLUMBING SERVICE INC
DANNY BOX LLC
DANNY VIA PLUMBING
DANNY VIA PLUMBING INC
DANNY W. BAKER, INC
DANNY'S POOLS OF SOUTHWEST FLORIDA, INC
DANS FAN CITY LLC
DANS HEATING AND COOLING INC
DANVA CONSTRUCTION SERVICES
DART POOL SOLUTIONS
DART POOL SOLUTIONS INC
DATACOMM NETWORKS INC
DAVCO ELECTRICAL CONTRACTORS
DAVE & RICK BUILDERS INC
DAVE FOOTE ENVIRONMENTAL CONST
DAVE LINCOLN CONTRACTING INC
DAVE'S AIR CONDITIONING INC
DAVENPORT PLUMBING INC
DAVENPORT POST POOLS
DAVID A SPADE INC
DAVID ANTINI ELECTRIC INC
DAVID ASH PLUMBING LLC
DAVID BAILEY INC
DAVID HARVEY ELECTRIC CO INC
DAVID HAVENS LEGEND CONTRACTING
DAVID HOMES & CONSTRUCTION INC
DAVID J SHEPARD JR LLC
DAVID JAMES TOPIAN (OWNER BUILDER)
DAVID KUXHAUSEN CONSTRUCTION LLC
DAVID P FINTAK ROOFING INC
DAVID PINKHAM (OWNER BUILDER)
DAVID PLUMBING INC
DAVID RICHARD SULLIVAN
DAVID S REYNOLDS ELECTRIC INC
DAVID W JOHNSON BUILDER INC
DAVID WEEKLEY HOMES
DAVID ZACHOS (OWNER BUILDER)
DAVIDSON SIGN SERVICES INC
DAVIS CONSTRUCTION GROUP SERVICES, INC
DAVIS ELECTRICAL SERVICE LLC
DAVIS GENERAL CONTRACTORS LLC
DAVIS JR PLUMBING INC
DAVIS PROPERTY SOLUTIONS LLC
DAVIS ROOFING OF SOUTHWEST FL
DAY PORT CONSTRUCTION SERVICES
DBH AIR CORPORATION
DBK INC
DC COASTAL LLC
DC HOME SERVICES OF SWFL INC
DCD ENTERPRISES OF MANASOTA
DCD WAVE TECHNOLOGIES INC
DCL ELECTRICAL SERVICES INC
DCR TAMPA LLC
DCT ELECTRICAL SERVICES
DE BLANCO CONSTRUCTION INC
DE MURPHY CONSTRUCTORS INC
DE ROBINSON CONSTRUCTION GROUP LLC
DEAC'S
DEAH ELECTRIC LLC
DEAL ELECTRIC COMPANY
DEAN L PAQUET PE
DEANGELIS DIAMOND CONSTR INC
DECKER PLUMBING & DRAINS LLC
DECLERCQ CONSTRUCTION INC
DECORATIVE FOAM WALL & FENCES
DECORT ELECTRICAL SOLUTIONS INC
DEEGAN ELECTRIC
DEEM LLC
DEFINITIVE EDGE CONCRETE INC
DEHART ALARM SYSTEMS INC
DEJON CONSTRUCTION INC
DEJONGE EXCAVATING CONTRACTORS INC
DEKOR LLC
DEL'S ELECTRICAL SERVICE, INC
DEL-AIR HEATING AIR CONDITIONING & REFRIGERATION INC
DELS ELECTRICAL SERVICE INC
DELTA SOUTHERN CONSTRUCTION
DELTA Y ELECTRIC SERVICES, LLC
DELUXE GARAGE DOORS LLC
DELVIN ORELLANA (OWNER BUILDER)
DEMING & DEMING CONSTRUCTION
DEMING CONCRETE & MASONRY
DEMO DOG DEMOLITION LLC
DEMPSEY ROOFING COMPANY INC
DENHAM'S ALUMINUM & SCREEN
DENNIS A. BARTH LANDSCAPE ARCHITECT, LLC
DENNIS BACON CONSTRUCTION INC
DENNIS EADY ROOFING
DENNIS M TAYLOR PLUMBING INC
DEPARTMENT OF GREEN ENERGY INC
DEPENDABLE AIR CONDITIONING
DEPENDABLE AIR LLC
DEPUE CONSTRUCTION LLC
DERRICK KNEPP INC
DES BUILDING LLC
DESIGN AIR HEATING COOLING
DESIGN AND REMODELING SOLUTIONS INC
DESIGN CONSTRUCTION AND ALUMINUM 'LLC'
DESIGN ELECTRICAL CONTRACTING
DESIGN IT BUILD IT INC
DESIGN SRQ INC
DESIGN TEMP OF FLORIDA INC
DESOTO MANUFACTURED HOME SVC
DESTINATION POOLS LLC
DESTINY CONSTRUCTION AND CONSULTING LLC
DETWEILERS PROPANE GAS SERVICE
DEUTSCH ELECTRIC INC
DEVCON SECURITY SERVICES (SRQ)
DEVCON SECURITY SERVICES CORP
DEVELOPERS OF SW FLORIDA INC
DEVELOPMENT AIR CONDITIONING AND HEATING INC
DEVINE ELECTRIC
DEVITTORI CUSTOM WOODWORKS INC
DEVOTO CONSTRUCTION OF SW FL
DFENZ
DGD FLORIDA AQUISITION, INC.
DGM AIR SOLUTIONS
DGS CONTRACTING INC
DH GRIFFIN CONSTRUCTION CO
DHARMA CONSTRUCTION SERVICES
DI PIAZZA CONSTRUCTION SERVICES, LLC
DIAMOND CONTRACTORS INC
DIAMOND CONTRACTORS LLC
DIAMOND HOMES LLC
DIAMOND SOLAR LLC
DIAMOND TURF
DIAMOND UNDERGROUND INC
DIAMOND'S ELECTRIC SIGNS INC
DICKERSON CONSTRUCTION INC
DIEBOLD INC
DIGITAL CLIMATE CONTROL INC
DIGITALHOMES CORP
DILLARD SMITH CONSTRUCTION
DIMITRESSE CONSTRUCTION, INC.
DIMON AIR INC
DIRECT ELECTRIC & WIRING INC
DIRECT HEATING & COOLING INC
DIRECT METAL ROOFING
DIRECT REMODELS LLC
DIRK'S PLUMBING SOLUTIONS LLC
DISCOUNT A/C & HEATING SERVICE
DISCOUNT A/C LLC
DISCOUNT A/C LLC (GERDEMAN)
DISCOUNT AWNINGS INC
DISCOUNT FENCE OF WEST FLORIDA INC
DIVERSE AIR CONDITIONING & REF
DIVERSE BUILDERS INC
DIVERSE PLUMBING LLC
DIVERSIFIED ADVANTAGE INC
DIVERSIFIED ENVIRONMENTAL CONSTRUCTION INC
DIVERSIFIED TELECOM SERVICES INC
DIVIDE ELECTRICAL SERVICES LLC
DIVINE PLUMBING INC
DIVISION 16 LLC
DIVISIONS UNLIMITED OF FLORIDA
DIXIE CONSTRUCTION SERVICES INC
DIXIE FIRE PROTECTION INC
DIXIE SIGNS INC
DIXON AND SONS PLUMBING LLC
DIXON MECHANICAL LLC
DJ GOULD ELECTRIC CO INC
DLG ELECTRIC, INC
DLT CONSTRUCTION LLC
DM CONSTRUCTORS LLC
DMG PLUMBING LLC
DMK ASSOCIATES INC
DMK DEVELOPMENT GROUP LLC
DMK SERVICES INC
DNA ELECTRIC LLC
DNC SOLUTIONS INC
DNM RESCREEN ETC
DOALL PLUMBING LLC
DOBSON ELECTRIC, INC
DOCKSIDE ELECTRIC LLC
DOCS REFRIGERATION & AIR CONDITIONING SERVICES LLC
DOLPHIN AIR
DOLPHIN AIR OF DESOTO COUNTY, INC
DOLPHIN AIR SYSTEMS INC
DOLPHIN FIRE LLC
DOLPHIN INNOVATIONS LLC
DOM'N NICK'S AIR CONDITIONING & HEATING INC
DOMA CONSTRUCTION LLC
DON BELL SIGNS LLC
DON JS ELECTRIC INC
DON LARGE PLUMBING INC
DON LESTER LLC DBA AIRNOW
DON WARNER ELECTRIC INC
DON YOUNG REPAIRS LLC
DON'S PLUMBING INC
DONALD GREENWOOD (OWNER BUILDER)
DONALD RUSE, LLC
DONE ONCE DONE RIGHT CONSTRUCTION LLC
DONE RIGHT CONSTRUCTION INC
DONOVAN WHITEHEAD CONSTRUCTION
DOOLEY & MACK CONSTRUCTORS INC
DOOLEYMACK CONSTRUCTORS LLC
DOOLITTLE AIR LLC
DOOR DEPOT OF SW FL INC
DORIA CONSTRUCTION INC
DORSETT SIGNS INC
DOUBLE G CONSTRUCTION CORP
DOUBLE THROW ELECTRIC INC
DOUG CLARK ELECTRIC
DOUG DUNNE ROOFING INC
DOUG DUNNE ROOFING INC
DOUG SCHRADER ELECTRIC INC
DOUGLAS CARLSON
DOUGLAS ELECTRIC INC
DOUGLAS H KRESGE LLC
DOUGLAS N HIGGINS INC
DOUGLASS RESTORATION INC
DOULOS CONSTRUCTION
DOWNEAST AIR HEATING & COOLING
DOWNTOWN RENTALS LLC
DOYLE ELECTRIC SERVICES INC
DPR CONSTRUCTION
DR ALUMINUM INC
DR COFFMAN CONSTRUCTION CO
DR CONSTRUCTION & HOME SERVICE
DR COOL AIR CONDITIONING & REFRIGERATION
DR GOODROOF INC
DR HORTON INC
DR PLATT CONSTRUCTION INC
DR ROOFERS
DR SWANSON COMPANY
DRAFTPROS INC
DRAIN DOCTORS INC
DRAIN MEDICS PLUMBING
DREAM CONSTRUCTION OF AMERICA INC
DREAM TOTAL HOME SOLUTIONS LLC
DREAMLINER
DREAMLINER
DRH CONSTRUCTION INC
DRH PLUMBING INC
DRM ENTERPRISES OF SARASOTA INC DBA DRM ELECTRICAL
DRMC CONSTRUCTION INC
DRY GUYS ROOFING & REPAIRS LLC
DRY ROOFING INCOM LLC
DRYMON REFRIGERATION INC
DRYWALL AUTHORITY & CONSTRUCTION, INC
DS SAUNDERS AND COMPANY INC
DSI CONSTRUCTION SERVICES
DSI GENERAL CONTRACTOR, INC
DUBAR ELECTRIC INC
DUFFY AIR SYSTEMS INC
DUGAN CONSTRUCTION INC
DUGGAN CONSTRUCTION AND ROOFING LLC
DUKE DOES IT ELECTRIC LLC
DUNAMIS ELECTRIC INC
DUNCAN BUILDERS INC
DUNCAN SEAWALL DOCK AND BOAT LIFT LLC
DUNN & DENHAM CONSTRUCTION
DUNN ENTERPRISES OF SARASOTA
DUQUE ROOFING, INC
DURABLE ROOFING COMPANY
DURAMADE WINDOWS & DOORS INC
DURAMAX ROOFING & CONSTRUCTION LLC
DURLACH INDUSTRIES INC
DUSS ENTERPRISES INC
DUVALL HEATING & AIR CONDITION
DUWET INC
DUYN CONSTRUCTION LLC
DVOR ELECTRIC LLC
DW AIR SERVICES INC.
DW GREEN GENERAL CONTRACTORS
DWIGHT D ELAM ELECTRIC
DYEGRAM CONSTRUCTION LLC
DYMAXAEON LLC
DYNAFIRE LLC (ALARM)
DYNAFIRE LLC (SPRINKLER)
DYNAMIC ASPECTS INC
DYNAMIC HEATING & COOLING INC
DYNAMIC NATIONAL
DYNAMIC SOUTH, INC
DYNAMIK DESIGN PARTNERS
DYNAN CONSTRUCTION LLC
DYNASTY BUILDING SOLUTIONS LLC
E & F CONSTRUCTION INC
E & SON ELECTRIC CORP
E&R ALUMINUM LLC
EAB CONSULTING GROUP LLC
EAGLE CREEK HOMES INC
EAGLE DEVELOPMENT
EAGLE ELECTRICAL CONTRACTING INC
EAGLE ROOFING & RESTORATION LLC
EAM ROOFING LLC
EAMON WALSH CONSTRUCTION INC
EARL HUNTER ELECTRIC INC
EARLEY CONTRACTING LLC
EARTH TECH (DE) LLC
EARTHWORKS LAND DEVELOPMENT
EASIAIR COOLING & HEATING INC
EAST COAST COMMERCIAL CONTRACTORS LLC
EAST COAST ELECTRIC CO., LLC
EAZY BREEZY LLC
EB ROOFING, INC.
EBANKS ELECTRIC LLC
ECKLIN AIR CONDITIONING
ECLIPSE ALUMINUM & SHADE LLC
ECLIPSE SOLAR INC
ECO MARINE SOLUTIONS, LLC
ECO ONE PLUMBING SERVICES, INC.
ECO ROOF AND SOLAR, INC.
ECO-LOGICAL ROOFING, LLC
EcoBuild Professional, LLC
ECONOMY POOL SUPPLIES & SERV
ECS FLORIDA, LLC
ED ALUMINUM CONSTRUCTION INC
ED CHUPP ELECTRIC INC
ED MOORE COMPANY INC
ED SEIFRIED CONSTRUCTION INC
ED TAYLOR CONSTRUCTION SOUTH
ED'S RELIABLE LAWN SERVICE INC
EDGAR ELECTRIC SERVICE INC
EDGEWATER CONTRACTORS INC
EDMONSON ELECTRIC INC
EDWARD BURKETT (OWNER BUILDER)
EDWARD L CAMP CONSTRUCTION
EDWARD ROSS CONSTRUCTION SERVICES INC
EDWARDS ELECTRIC CORP
EDWIN D TAYLOR II TRUST
EF DEVINE CONSTRUCTION INC
EFFECTIVE ELECTRIC INC
EFFICIENT GUTTERS LLC
EFFICIENT HOME SERVICES OF FLORIDA LLC
EGOLF ENTERPRISES LLC
EGP ELECTRICAL LLC
EGUARD ROOF & SAFETY SYSTEMS LLC
EHS CONSTRUCTION SERVICES LLC
EIFFEL HOMES CONSTRUCTION & DEVELOPMENT
EISENMANN CONSTRUCTION INC
EJ CONS & ROOFING LLC
EJZ ELECTRICAL SERVICES, LLC
ELDORADO MIRANDA MFG CO INC
ELECTED ELECTRIC LLC
ELECTRIC COMPANY OF SOUTH FLORIDA
ELECTRIC MACHINERY ENTERPRISE
ELECTRIC SOLUTIONS OF SWFLA INC
ELECTRIC SOLUTIONS UNLIMITED LLC
ELECTRIC WORLD CORP
ELECTRICAL CONSTRUCTION & COMMUNICATIONS INC
ELECTRICAL CONSTRUCTION & SVC
ELECTRICAL CONTRACTING LLC
ELECTRICAL CONTRACTOR STIPO
ELECTRICAL ENTERPRISES LLC
ELECTRICAL INVESTMENT GROUP LLC
ELECTRICAL INVESTMENT GROUP-INACTIVE
ELECTRICAL MAINT SYSTEMS INC
ELECTRICAL MAINTENANCE AND SERVICES INC
ELECTRICAL MD INC
ELECTRICAL SERVICE & MAINT
ELECTRICAL SERVICE MASTERS INC
ELECTRICAL SOLUTIONS FOR ALL LLC
ELECTRICAL SOLUTIONS OF SW FLORIDA INC
ELECTRICAL WORKS
ELECTRICITY LLC
ELECTRICITY OF SARASOTA INC
ELECTRONIC PROTECTION SYSTEMS
ELECTROTEK SERVICES INC
ELEGANT MAKEOVERS LLC
ELEGANT WATERS INC
ELEMENT REPAIR REMODELING LLC
ELEMENTS CONSTRUCTION INC
ELEVATE ROOFING AND EXTERIORS INC
ELEVATION RESTORATION LLC
ELIAS BROTHERS GENERAL CONTR
ELIE ELECTRIC SERVICES LLC
ELIER CARRERA
ELITE AIR COOLING LLC
ELITE ALUMINUM ETC INC
ELITE ALUMINUM OF FLORIDA LLC
ELITE BUILDERS GROUP INC
ELITE CONTRACTING INC
ELITE CONTRACTORS INC
ELITE CREW SERVICES LLC
ELITE CUSTOM PLUMBING INC
ELITE ELECTRICAL CONTRACTORS LLC
ELITE ELECTRICAL SERVICES AIR CONDITIONING & REFRIFERATION
ELITE ELECTRICAL SOLUTIONS OF TAMPA BAY LLC
ELITE HEATING & AIR INC
ELITE HURRICANE PROTECTION LLC
ELITE IMAGES ADVERTISING
ELITE PERMITS OF SARASOTA
ELITE PLUMBING DESIGNS OF TAMPA BAY INC
ELITE ROOFING SYSTEMS LLC
ELITE SERVICES SRQ LLC
ELITE WEILER POOLS INC
ELK RIDGE CUSTOM HOMES LLC
ELLIOTT AIR SYSTEMS INC
ELLIOTT CUSTOM HOMES & CONTRACTING INC
ELLIOTT SERVICES INC
ELLIS D GOOD CONSTRUCTION LLC
ELLIS SPARKS ELECTRIC INC
ELLISON GENERAL CONTRACTOR INC
ELLSWORTH HEATING AND COOLING INC
ELM CONTRACTING LLC
EM PHILLIPS CONSTRUCTION CO
EMBLEM CONSTRUCTION LLC
EMERALD COAST PERMITTING INC
EMERY AIR CONDITIONING INC
EMG
EMPERIAL PLUMBING INC
EMPIRE AIR SERVICES INC
EMPIRE BUILDERS & REMODELING LLC
EMPIRE ELECTRIC SERVICE INC
EMPIRE ELECTRIC SIGNS INC
EMPIRE ELECTRIC SOLUTIONS, LLC
EMPIRE ENERGY INC
EMPIRE ROOFING & RESTORATION INC
EMPIRE ROOFING SOLUTIONS, L.L.C.
EMS CONTRACTING
ENCI CONSTRUCTION
ENCLOSURE PROS LLC
ENDURA CONSTRUCTION INC
ENDURANCE AIRE LLC
ENERGY AIR INC
ENERGY CRISIS INC
ENERGY SOLUTIONS DIRECT
ENERGY TODAY
ENGER PLUMBING INC
ENGINEERED AIR SYSTEMS INC
ENGINEERED ELECTRIC SERVICES
ENGINEERED SYSTEMS SOLUTIONS LLC.
ENGLEWOOD AIR CONDITIONING
ENGLEWOOD ELECTRIC INC
ENGLEWOOD FENCING LLC
ENGLEWOOD GLASS & MIRROR
ENGLEWOOD ROOFING INC
ENGLEWOOD UNDERGROUND INC
ENHANCED ALUMINUM LLC
ENLIGHTEN ELECTRICAL LLC
ENO ELECTRIC INC
ENTERPRISE CONSTRUCTION GROUP
ENTERPRISE ELECTRIC LLC
ENVERA SYSTEMS
ENVIRO-TECH LLC
ENVIRONMENTAL ELECTRICAL SERVICES INC
ENVIRONMENTAL EQUIPMENT INC
ENVIRONMENTAL EQUIPMENT SALES INC
ENVIRONMENTAL PROFESSIONAL
ENVIROSTRUCT LLC
ENVIROTEC AIR INC
ENVIROTEC HEATING & COOLING INC
EON ROOFING & WINDOW INC
EP ARCHITECTURE LLC
EP KNAPP INC
EPI CONSTRUCTION INC
EPIC POOL & SPA LLC
EPIC ROOFING AND EXTERIORS, LLC
EPIC ROOFING SERVICES INC
EQUIX ENERGY SERVICES
ERICKSONS DRYING SYSTEMS INC
ERICSSON INC
ERIDEL CONSTRUCTION AND DESIGN LLC
ERIE CONSTRUCTION MID-WEST LLC
ERIK STUART HOME SERVICES, LLC
ERNIE ADAMS COOLING & HEATG, INC
ERNIE ADAMS COOLING HEATING
EROSION RESTORATION, LLC
ERS CONSTRUCTION
ERVIN MILLER CONSTRUCTION INC
ESCOBAR ESCOBAR & HEREDIA
ESD HOME SOLUTIONS LLC
ESSOR CONSTRUCTION GROUP INC
ESTEBAN ELITE ROOFING INC
ETD ELECTRICAL SERVICES LLC
ETHICS LOYALTY SERVICE CONSTRUCTION, INC.
EUREX SHUTTERS
EUROPEAN QUALITY DESIGN LLC
EVANROSE PLUMBING INC
EVANS ROOFING AND RAIN GUTTERS, INC.
EVELYN ALFORD (OWNER BUILDER)
EVERDEAN CONSTRUCTION
EVEREST AIR CONDITIONING INC
EVEREST ROOFING LLC
EVERETT GROUP USA LLC
EVERSEAL
EVERYDAYPLUMBER.COM LLC
EVOLUTION ELECTRICAL CONTRACTOR GROUP LLC
EVOLUTION ROOFING & REPAIR LLC
EVOLVE CONSTRUCTION LLC
EXCEL PLUMBING SERVICES
EXCEL PROJECT MANAGEMENT LLC
EXCELSIOR DEVELOPMENT CO LLC
EXCEPTIONAL AIR & HEATING LLC
EXCLUSIVE CONSTRUCTION CO
EXECUTIVE COOLING AND HEATING
EXECUTIVE ELECTRONICS OF SW FL
EXPERIENCED AIR, LLC
EXPERT INSTALLATION SERVICE
EXPERT ROOFERS
EXPERT ROOFING AND CONSTRUCTION LLC
EXPERTS PLUMBING SERVICES LLC
EXPONENTIAL LLC
EXPRESS AIR SYSTEMS CORP
EXPRESS TRAILERS OF SARASOTA
EXTERIOR CONSULTANTS INC
EXTREME DEMOLITION AND LAND CLEARING
EXTREME ROOFING INC
EYDON CONSTRUCTION LLC
EZ DOCK MARINE INC
EZ ROOFING INC
EZ SERVICES SARASOTA LLC
EZE AIR SOLUTIONS
F & J FLORIDA INVESTMENT LLC
F RONALD LACIVITA INC
F&L ELECTRIC COMPANY, INC
F&M CUSTOM HOME BUILDERS LLC
F.H. PASCHEN, S.N. NIELSEN & ASSOCIATES LLC
F.W. WALTON, INC.
FABRI-TECH SCREEN ENCLOSURES LLC
FAIRFAX CORPORATION
FAIRWAY HEATING & COOLING
FAITH BUILDERS
FAITH ELECTRIC INC
FAITHBILT BUILDERS INC
FAITHFUL HEATING & COOLING INC
FALCON CONSTRUCTION LLC
FALCON ELECTRIC INC
FALING CONSTRUCTION INC
FAMILY AIR CONDITIONING LLC
FAMILY POOLS
FAMILY PRIDE ROOFING INC
FAMILYFIRST ROOFING GROUP LLC
FAMOUS ROOFING LLC
FANSLER CONSTRUCTION, LLC
FARFAN CONTRACTORS LLC
FARGNOLI'S CARPENTRY INC
FARGNOLIS CARPENTRY INC
FARHA ROOFING KC, LLC
FAST ACTION PLUMBING INC
FAST OF FLORIDA INC
FAST REHABS
FASTSIGNS OF CLEARWATER
FASTSIGNS SARASOTA
FASWD LLC
FATHOM POOLS & SERVICES, LLC
FAULKNER INC
FAV Restoration LLC
FAZIO SERVICES LLC
FBC INSPECTION SERVICE
FEDERAL ELECTRIC INC
FELKERS COOLING AND HEATING LLC
FELSON DEVELOPMENT & CONSTR
FENCE DYNAMICS
FENCE FANATICS LLC
FENCE MASTER PRO LLC
FENCE NEAR ME LLC
FENCE OUTLET OF NORTH PORT
FENZEL AIR SERVICES
FERGUSON CONSTRUCTION AND ALUMINUM
FERNANDEZIGN CONSTRUCTION INC
FERRELL GAS
FERRELLGAS
FERRELLGAS LP
FERRELLGAS LP (YOUMANS)
FERREY ELECTRIC CORP
FERRISO ELECTRIC LLC
FETZ ELECTRIC INCORPORATED
FFI CONTRACTING SERVICES
FHIA LLC
FHM CONSTRUCTION
FHS INDUSTRIAL CONSTRUCTORS
FIBER SOLUTIONS OF SW FLORIDA
FIDELITY AIR & REFRIGERATION
FIELD TECH AIR CONDITIONING & HEATING LLC
FILIP PLUMBING LLC
FILTERWORKS USA INC
FINCH ROOF CONSULTING LLC
FINE CONSTRUCT LLC
FINETECH INC
FINFROCK CONSTRUCTION LLC
FINISH-LINE COOLING & HEATING LLC
FINISHING TOUCH LIGHTING LLC
FIRE ALARM & ELECTRONICS ENG
FIRE AND ICE HEATING AND AIR CONDITIONING INC
FIRE EQUIPMENT COMPANY OF FL
FIRE FIGHTER INC
FIRE ONE INC
FIRE SAFETY SPECIALISTS LLC
FIRE SPRINKLER SYSTEMS COMPANY
FIRELINE ENTERPRISES
FIREMASTER
FIRESERVICE INC
FIRESIDE HOMES
FIRETHORN INC
FIRST AND FOREMOST HEATING & AIR LLC
FIRST CHARLOTTE AC & REFRIG
FIRST CHOICE CONSTRUCTION INC
FIRST CHOICE DEVELOPERS LLC
FIRST CHOICE ELEC OF NP INC
FIRST CHOICE ELECTRICAL SOLUTIONS LLC
FIRST CHOICE PLUMBING INC
FIRST CLASS ALUMINUM STRUCTURES INC
FIRST DEFENSE FIRE PROTECTION
FIRST FLORIDA CONST & REMODEL
FIRST LIGHT HOME HEALTHCARE - TINA GIBSON
FIRST PLUMBING & A/C OF FL INC
FIRST RATE INTEGRATED FIRE SEC
FIRST RATE ROOFING WEST COAST INC
FIRST SERVICE CGC INC
FIT YOUR BUDGET ELECTRIC INC
FIVE D CONTRACTORS INC
FIVE STAR COMMERCIAL ROOFING INC
FIVE STAR PLUMBING INC
FIVE STAR PLUMBING OF SW FLORIDA INC
FIVE STAR RENOVATIONS INC
FIVE STARS COOLING AND HEATING
FL ROOFING COMPANY LLC
FL SPECIALTY ROOFING
FL-BUILDER LLC
FLA AIR AND MECHANICAL LLC
FLAGSHIP FIRE INC
FLAMINGO AC & HEATING SERVICES, LLC
FLAMINGO SIGNS LLC
FLANDERS GAS INC
FLASH CUSTOM METAL ROOFING INC
FLAT RATE PLUMBING. INC
FLATWORKS INC.
FLCEA, INC.
FLEURY'S PLUMBING LLC
FLEXIBLE BUILDERS INC
FLO ENERGY LLC
FLO-TECH SERVICES INC
FLORIDA AFFORDABLE AIR
FLORIDA AIR CARE
FLORIDA AIR COMFORT SERVICES LLC
FLORIDA AIR LLC
FLORIDA AIR WORKS INC
FLORIDA ALLIED CONTRACTOR SERVICES INC
FLORIDA ANCHOR & BARRIER CO
FLORIDA BUILDING PROS INC.
FLORIDA CERTIFIED ROOFING INC
FLORIDA CHOICE A/C & ELECTRIC LLC
FLORIDA COMFORT AIR COND
FLORIDA CONCRETE & FRAMING
FLORIDA CONCRETE & MASONRY INC
FLORIDA CONSTRUCTION & DESIGN, INC.
FLORIDA CONSTRUCTION CONTRACTING CORP
FLORIDA COOLING SOLUTIONS INC
FLORIDA CRAFTSMAN INC BAY AREA
FLORIDA DELTA MECHANICAL INC
FLORIDA ELECTRICAL POWER CORP
FLORIDA ENERGY & AIR SERVICES
FLORIDA ENGINEERING & SURVEYING
FLORIDA ENGINEERING LLC
Florida Engineering LLC
FLORIDA FAMILY HOMES INC
FLORIDA FENCE
FLORIDA FIRE AND SOUND INC
FLORIDA FOAM WALLS LLC
FLORIDA GAS SOLUTIONS LLC
FLORIDA GULF COAST UNDERGROUND LLC
FLORIDA HARBOR HOMES INC
FLORIDA HOME IMPROVEMENT ASSOC
FLORIDA HURRICANE & SOLAR
FLORIDA HURRICANE + SOLAR PROT
FLORIDA INTEGRITY CONSTR CO
FLORIDA LIFE SAFETY LLC
FLORIDA LIFETIME IMPACT WINDOW
FLORIDA LIGHTING MAINTENANCE
FLORIDA LOW VOLTAGE SYSTEMS, LLC
FLORIDA METAL BUILDING SERVICES LLC
FLORIDA MOBILE HOME SUPPLY INC
FLORIDA MOBILE MASTERS INC
FLORIDA MUNICIPAL INSPECTIONS LLC
FLORIDA OUTDOOR LIVING
FLORIDA PIPE-LINING SOLUTIONS
FLORIDA PIPING SOLUTIONS LLC
FLORIDA PLASTERING CONTRACTORS
FLORIDA PLAYSTRUCTURES & WATER FEATURES INC
FLORIDA POOL PROFESSIONALS, INC
FLORIDA POWER & LIGHT (SARASOTA)
FLORIDA POWER & LIGHT COMPANY (PUNTA GORDA)
FLORIDA POWER MANAGEMENT
FLORIDA POWER SERVICES INC
FLORIDA POWER SOLUTIONS INC
FLORIDA PREMIER CONTRACTORS, LLC
FLORIDA RENOVATOR SPECIALIST LLC
FLORIDA ROOF & BUILDING SERVICES LLC
FLORIDA ROOF MASTERS, LLC
FLORIDA ROOFING & CONSTRUCTION LLC
FLORIDA ROOFING EXPERTS
FLORIDA SHED COMPANY INC
FLORIDA SHORELINE & FOUNDATION EXPERTS LLC
FLORIDA SIGN COMPANY INC
FLORIDA SOLAR DESIGN GROUP
FLORIDA SOLAR POWER GROUP INC
FLORIDA SOUTHERN ROOFING & SHEET METAL INC
FLORIDA STATE CERTIFIED ROOFING LLC
FLORIDA STATE FENCE CORP
FLORIDA STATE GENERAL CONTRACTORS
FLORIDA STATE ROOFING
FLORIDA STATE ROOFING AND CONSTRUCTION INC
FLORIDA SUN SERVICES,LLC
FLORIDA ULTIMATE IMPROVEMENTS LLC
FLORIDA URETHANE & COATINGS
FLORIDA WALLS AND CEILINGS
FLORIDA WEST COAST WINDOWS INC
FLORIDA WINDOW & DOOR
FLORIDA WINDOW GEEKS LLC
FLORIDA'S AC DEPOT LLC
FLORIDA'S COOLEST AIR CONDITIONING AND HEATING INC
FLORIDA'S PROFESSIONAL SCREENING LLC
FLORIDAS WEST COAST AIR CONDITIONING & HEATING INC
FLOW MASTERS PLUMBING SOLUTIONS INC
FM CONTRACT SERVICE LLC
FM DEPENDABLE ELECTRIC & AUDIO INC
FOCUS ELECTRICAL SERVICES
FONTANYI FENCE
FONTANYI HOME IMPROVEMENTS INC
FONZ HEATING & AIR LLC
FOR SERVICE INC
FOREMOST FENCE LLC
FORMELLA CONSTRUCTION LLC
FORRISTALL ENTERPRISES INC
FORT KNOX FIRE & COMMUNICATION
FORTUNE ELECTRICAL CONSTRUCTION LLC
FORUM CONSTRUCTION GROUP INC
FOSTER'S AIR SUPPLIES & TECH
FOUNDATION AIR LLC
FOUNDATION CONTRACTING GROUP LLC
FOUNDATION TECHNOLOGIES
FOUNTAIN POOLS & WATER FEATURES
FOUR SEASONS AIR CONDITIONING INC
FOUR WAY PLUMBING INC
FOURNIER A/C & REFRIGERATION
FOWLER CONSTRUCTION SERVICES LLC
FOX GROUP LLC
FOX PLUMBING SERVICES INC
FOX POOLS INC
FOX ROOFING GROUP LLC
FOX ROOFING INC
FOX WINDOW & GLASS LLC
FOXTROT ROOFING INC
FP PROPERTY RESTORATION
FPI CONSTRUCTION INC
FPL ENERGY SERVICES INC
FPL READI POWER LLC
Francis P. Lagattuta
FRANCISCUS ROOFING OF FL INC
FRANK NIST ELECTRIC
FRANK W MILLER CONSTRUCTION
FRANK'S HEATING & COOLING
FRANKLIN ELECTRIC CO
FRANKLIN'S PLUMBING LLC
FRANZESE PLUMBING INC
FRASER ROOFING L.L.C.
FRED M STARLING INC
FRED RAYNER AIR CONDITIONING
FRED SHUTE REAL ESTATE & DEV
FRED'S AIR CONDITIONING
FREDERICK DERR & COMPANY INC
FREEDOM AIR CONDITIONING & ELECTRIC INC
FREEDOM BUILDERS OF SWFL, LLC
FREEDOM CODE COMPLIANCE
FREEDOM FENCE BUILDERS LLC
FREEDOM FOREVER FLORIDA LLC
FREEDOM POOLS AND SPAS LLC
FREEDOM ROOFING
FREEDOM SOLAR POWER LLC
FREEPORT FOUNTAINS LLC
FREES INC OF LA
FREESE JOHNSON, LLC
FREESTYLE POOLS & SPAS LLC
FREEZIN' AIR HEATING & COOLING
FRENCH'S AIR CONDITIONING INC
FRESCO A/C LLC
FRESH AIR COOLING HTG & REFRIG
FRESH START DEVELOPMENT INC
FRIELER CONSTRUCTION INC
FRIENDLY SUNCOAST POOLS
FROGWATER ENTERPRISES INC DBA SHEA ELECTRIC
FRONCKOWIAK & CO CONST INC
FRONTIER FLORIDA LLC
FROSTY AIR & HEAT INC
FROSTY FLAMINGO HVAC SERVICES, LLC
FRS ENVIRONMENTAL REMEDIATION
FRS FABRICATION INC
FS BUILDERS & ASSOCIATES INC
FSGC LLC
FSI OF SARASOTA
FTL ELECTRIC LLC
FUENTES SCREENS ENT INC
FULL FORCE FIRE PROTECTION INC
FULL SAIL BUILDERS INC
FULL SERVICE ALUMINUM INC
FULLER GROUP CONSTRUCTION LLC
FUQUA ELECTRIC INC
FURLONG SEAWALLS LLC
FUSION MANAGEMENT & REALTY GROUP LLC
FUSS FREE AC LLC
FUTURE BUILDERS CORP
FUTURE HOMES BY GEORGE LLC
FUTURISTIC CONSTRUCTION INC
FYXIFY HOME SERVICES LLC
G & G METROTECH SERVICES INC
G SCREEN AND GUTTER INC
G&D ROOFING INC
G&J POOL REPAIRS LLC
G&R COOLING AND HEATING LLC DBA AA TEMPERATURE SERVICES
G&S COASTAL ROOFING INCORPORATED
G&S CONSTRUCTION SERVICES INC
G&S POOL SUPPLY INC
G-SUS CONSTRUCTION INC
G-TECH ELECTRIC INC
G.O.D. METAL BUILDING SERVICES INC.
GABLE WINDOW REPLACEMENT INC
GABLES AIR CONDITIONING CORP
GADOURY & GADOURY & ASSOC
GAETANO POOLS INC
GAF ENERGY LLC
GAGNON CONSTRUCTION SERVICES
GAIR'S ABLE AIR INC
GALAXY POOLS
GALAXY POOLS
GALE FORCE ROOFING AND RESTORATION, LLC
GALLAGHER ELECTRICAL SERVICES
GALLANT CONSTRUCTION COMPANY INC
GALLO PLUMBING SERVICES INC
GALLOWAY ROOFING
GALLOWAY ROOFING LLC
GALVANO CONSTRUCTION LLC
GALVANS FENCING SOLUTIONS LLC
GANT ELECTRIC INC
GAP BUILDING SERVICES LLC
GAPRA CONSTRUCTION LLC
GAPSS INC
GARAGE DOORS OVER CHARLOTTE
GARAGE SERVICE TODAY
GARROD ENTERPRISES INC
GARY AIR INC
GARY BURTON SCHMITT CONSTR INC
GARY HIRTZ CONSTRUCTION INC
GARY KOSMOS ELECTRICAL CONTR
GARY W GELUSO ENTERPRISES INC
GARY'S PLUMBING AND PUMP SERV
GARY'S ROOFING SERVICE INC
GAS PROS INC
GAS SERVICE CENTER LLC
GAS TAXI INC
GasBusters LLC
GASMASTERS INC
GASPARILLA CONSTRUCTION INC
GASPARILLA PLUMBING
GATES BUTZ INSTITUTIONAL CONST
GATES CONSTRUCTION
GATEWAY CORPORATION OF SW FL INC
GATOR AIR CONDITIONING AND PLUMBING INC
GATOR CONSTRUCTION OF S FL INC
GATOR CREEK BUILDERS LLC
GATOR DRAIN AND PLUMBING
GATOR DREDGING
GATOR GRADING & PAVING LLC
GATOR MECHANICAL OF TAMPA BAY
GATOR PLUMBING INC
GATOR ROOFING OF BRADENTON
GAYCO ELECTRIC COMPANY INC
GAYLOR GROUP INC
GCA BUILDING INC
GCG CONSTRUCTION, INC.
GCS RESTORATION AND ROOFING LLC
GE JOHNSON CONSTRUCTION INC
GEC SERVICES OF SW FL INC
GEM STATEWIDE PLUMBING INC
GEN-POWER
GENERAL PLUMBING SERVICES INC
GENERAL ROOF SOLUTIONS INC
GENERAL ROOFING SOLUTIONS LLC
GENERAL UTILITY CONST INC
GENERATE SOLUTIONS LLC
GENERATION ELECTRIC INC
GENERATOR SUPERCENTER OF FORT MYERS
GENERX GENERATORS LLC
GENESIS INNOVATIVE BUILDING SERVICES LLC
GEORGE E SKAGGS III INC
GEORGE F YOUNG INC
GEORGE HEWITSON CONTRACTING
GEORGE MOERLER INC
GEORGES MOBILE HOME SERVICE
GEORGIA MECHANICAL INC
GERALD BARRETT INC
GERARD J COUTURE LLC
GERARDI CONSTRUCTION INC
GERDES CONSTRUCTION INC
GERDY'S HEATING AND AIR CONDITIONING
GERELCO ELECTRICAL CONTRACTORS INC
GERRY POLITSCH ELECTRIC INC
GERRY'S PLUMBING SERVICE INC
GES GENERAL CONTRACTORS LLC
GET COASTAL EXTERIORS INC
GET COASTAL EXTERIORS INC.
GETTLE POOLS INC
GFI ROOFING SERVICES LLC
GH ELECTRICAL SERVICES LLC
GIANNETTI CONTRACTING CORPORATION
GILBANE BUILDING COMPANY
GILBERT DESIGN BUILD CORP
GILLETTE MASONRY CONTRACTING
GILLEY'S CUSTOM HOMES INC
GILLEY'S CUSTOM POOLS INC.
GILLIS CONSTRUCTION
GILMORE AIR SERVICES LLC
GINGERBREAD TRIM CO OF SAR INC
GINGERICH GLASS & ALUMINUM INC
GIRARDS CONTRACTING INC
GIULIANO CONTRACTING LLC
GIZA ROOFING SOLUTIONS, INC
GJC WINDOW & DOOR CO
GLABE FAMILY ELECTRIC INC
GLADES CONSTRUCTION LLC
GLASS TECHNIQUE INC
GLAUSER ROOFING SERVICES, LLC
GLENN HENEAULT GENERAL CONST C
GLOBAL AIR CONDITIONING INC
GLOBAL ATLANTIC CONST SERVICES
GLOBAL BOUNDARIES
GLOBAL CONSTRUCTION INC
GLOBAL CONSTRUCTORS INC
GLOBAL EFFICIENT ENERGY LLC
GLOBAL ENGINEERING & CONTRACTING INC
GLOBAL FIBER OPTICS INC
GLOBAL GRAPHIC DESIGN III LLC
GLOBAL ROOFING & CONTRACTING LLC
GLOBAL SHUTTERS INC
GLOBAL TECHNICAL SOLUTIONS, LLC
GLORY CONTRACTING LLC
GLR INC
GLYNN ADDISON CORPORATION
GM HALL CORPORATION
GMA ARCHITECTS & PLANNERS LLC
GMP ROOFING
GMS ROOFING LLC
GN PLUMBING CORP
GNG CONSTRUCTION INC
GNS ELECTRIC INC
GO ROOF TUNE UP INC
GO SOLAR POWER, LLC
GOBBELL HAYS PARTNERS INC
GODFREY ENTERPRISES
GOFF COMMUNICATIONS INC
GOFF CONSTRUCTION INC
GOLD COAST FIRE & SECURITY INC
GOLD COAST FIRE PROTECTION LLC
GOLDEN CONSTRUCTION SERVICES
GOLDEN FUEL
GOLDEN HAMMER ROOFING INC
GOLDEN RULE CONSTR GROUP INC
GOLDEN RULE HEATING & COOLING
GOLDEN SANDS GEN CONTRACTORS
GOLIATH CONSTRUCTION SERVICES
GOLIATH CONTRACTING INC
GONE COASTAL ROOFING &BLDG LLC
GOOD NEIGHBOR ROOFING INC
GOOD PLUMBING INC
GOOD SAMARITAN PLUMBING LLC
GOOD WOOD & STONE BUILDERS LLC
GOOD WORK CONSTRUCTION LLC
GOODLESS INTERSTATE ELECTRIC
GOODMAN TELECOM SERVICES, LLC
GOODSON ELECTRIC CONTRACTORS
GOODWIN ELECTRIC INC
GOPHER ROOFING LLC
GORDON & ASSOCIATES INSPECTIONS LLC
GORDON BROWN ELECTRIC INC
GORILLA ROOFING, INC.
GOSHORN PLUMBING COMPANY
GOTCHER HOMES & BUILDING CONST
GOULD'S AIR CONDITIONING & HEATING LLC
GP PLUMBING CORP
GRABER CONSTRUCTION INC
GRABER'S EXCAVATING INC,
GRACE AIR CONDITIONING AND HEATING LLC
GRAHAM ELECTRIC OF FL INC
GRAHAM ELECTRICAL CONTRACTORS
GRAHAM HEATING & AIR CONDITIONING, LLC
GRANDE AIRE SERVICES INC
GRANNELL ENTERPRISES INC
GRANT POOLS INC
GRAY'S PLUMBING, LLC
GRAYBELL PLUMBING REPAIR INC
GRAYHAWK REMODELING LLC
GRAYHAWK ROOFING SOLUTIONS INC
GRAYHAWK SYSTEMS LLC
GREAT DANE PETROLEUM CONTRS
GREAT SOUTHERN BUILDERS GULF COAST
GREAT WHITE MECHANICAL LLC
GREATER BAY PLUMBING LLC
GREATER BAY ROOFING INC
GREEN COAST EXTERIORS LLC
GREEN CONSTRUCTION SERVICES, LLC
GREEN COOLING SOLUTIONS
GREEN EARTH COMMERCIAL CONTRACTING COMPANY
GREEN MOUNTAIN HOLDINGS INC DBA JOY COMMUNICATIONS
GREEN ROOFING & WATERPROOFING TECHNOLOGIES LLC
GREEN VISTA ROOFING, LLC
GREENBRIAR GENERAL CONTRACTING
GREENPOINT CONSTRUCTION SERV
GREENREADY LLC
GREENTOPPS LANDSCAPE MAINTENANCE AND TREE SERVICE
GREG ROY PLUMBING LLC
GREGG ELECTRIC CORPORATION
GREGG HASSLER BUILDER INC
GREGORY PADUCH
GREGORY RALPH
GREGORY S SHAW INC
GREGORY SHORT (OWNER BUILDER)
GRIGGS PLUMBING CO
GRIMEFIGHTERS CARPET CLEANING
GRINDSTONE CONSTRUCTION INC
GRIPPO CONSTRUCTION SERVICES LLC
GROUND/WATER TREATMENT & TECH
GROVE CITY ELECTRIC INC
GRUNAU COMPANY INC
GSD FLORIDA LLC
GT WINDOW & DOOR INC
GUARANTEED ELECTRIC INC
GUARDIAN AIR LLC
GUARDIAN FUELING TECHNOLOGIES LLC
GUARDIAN PROTECTION SERVICES INC
GUARDIAN SOLAR LLC
GUENGERICH ELECTRIC INC
GUIDO'S CONSTRUCTION
GUITARD, RAMON II
GULF & SOUTHERN MECHANICAL INC
GULF ATLANTIC FENCING INC
GULF BREEZE ENTERPRISES BY J&J LLC
GULF COAST ALUMINUM
GULF COAST CARPET CLEANING & DISASTER SERVICE LLC
GULF COAST CONSTRUCTION
GULF COAST CONTRACTORS LA LLC
GULF COAST ELECTRICAL CONTRS
GULF COAST ELECTRICAL OF MANATEE AND SARASOTA INC
GULF COAST FENCE LLC
GULF COAST FIRE & SAFETY EQUIP
GULF COAST FIRE AND SECURITY
GULF COAST HANDYMAN AND HOMEWATCH SERVICES LLC
GULF COAST HOME PRODUCTS INC
GULF COAST OVERHEAD DOORS LLC
GULF COAST PLUMBING OF CENTRAL FLORIDA INC
GULF COAST POOL
GULF COAST RESTORATION & CARPET CLEANING
GULF COAST ROOFING & SHEET METAL INC
GULF COAST SCREENING & ALUMINU
GULF COAST SECURITY GATES LLC
GULF COAST SIGNS OF SARASOTA INC
GULF COAST SOLAR, LLC
GULF COAST SOLUTIONS
GULF COAST WINDOWS AND MORE INC
GULF COAST WOOD WORKS INC
GULF CURRENT ELECTIRC LLC
GULF ELECTRIC COMPANY
GULF ELECTRICAL SERVICE LLC
GULF GATE ALUMINUM INC
GULF GATE PLUMBING LLC
GULF GATE ROOFING INC
GULF LIFE PERMITTING SERVICES, LLC
GULF PEAK CONSTRUCTION LLC
GULF SHAMROCK INC
GULF SHORE COOLING INC
GULF SIDE SERVICES OF SARASOTA LLC
GULF TO BAY CONTRACTING INC
GULF TO BAY PLUMBING INC
GULF WESTERN ROOFING & SHEET
GULFCOAST DREAM BUILDERS
GULFCOAST FIRE & SAFETY
GULFCOAST PLUMBING CORP
GULFSIDE AIR COND & HEATING
GULFSIDE CONTRACTORS
GULFSIDE ELECTRIC OF SWFL LLC
GULFSIDE GAS SERVICES, LLC
GULFSIDE INVESTMENTS, LLC
GULFSIDE LANDSCAPE SERVICES
GULFSIDE REFRIGERATION INC
GULFSIDE WINDOWS AND DOORS LLC
GULFSTREAM CONSTRUCTION
GULLICK CONSTRUCTION INC
GUNNESS ELECTRICAL CONTRACTING
GUY BROTHERS ROOFING CO INC.
GUY PELUSO AIR CONDITIONING CUSTOM METAL INC
GUY R LARKIN JR GENERAL CONTRACTOR LLC
GUY'S DIVERSIFIED INC
GVM GROUP INC
H&H MECHANICAL
H&H SIGNS INC
H&R BUILDERS INC
H&Y ELECTRIC INC
H&Y FENCE COMPANY
H2O PLUMBING
HAAS'S COOLING & HEATING CORP
HABITAT FOR HUMANITY SOUTH SARASOTA COUNTY
HABITAT GROUP INC
HAE CONTRACTORS, LLC
HAGARTY HOME IMPROVEMENT INC
HAGEN CONSTR & DEVELOPMENT LLC
HAINES CARPENTRY & REMODELING
HALCON INDUSTRIES INC
HALEY'S PLUMBING COMPANY, INC
HALFACRE CONSTRUCTION COMPANY
HALFLANTS + PICHETTE STUDIO FOR MODERN ARCHITECTURE INC
HALL BROS ROOFING AND CONSTRUCTION INC
HALL ELECTRIC INCORPORATED
HALO ELECTRIC LLC
HAMCO HEATING & COOLING LLC
HAMILTON HEATING & COOLING INC
HAMLIN PLUMBING INC
HAMMER BROTHERS CONSTRUCTION SERVICES LLC
HAMMERHEAD ENTERPRISES INC
HAMMERTIME RESIDENTIAL CONSTR
HAMMOND PLUMBING SERVICES LLC
HAMSHER HOMES INC
HANDICAP ACCESSIBILITY LLC
HANDY AIR LLC
HANDY MC INC
HANDYMAN ROOFING
HANDYPRO OF SARASOTA
HANLY CONSTRUCTION INC
HANSEN ROOFING SERVICES LLC
HAPPY HOME SERVICES
HAPPY HOME SERVICES INC
HARBINGER
HARBOR HOME BUILDERS, LLC
HARBOR POINT CONSTRUCTION LLC
HARBOR VIEW ELECTRIC LLC
HARBOUR ROOFING
HARDESTY ELECTRIC SERVICE INC
HARDIE CONSTRUCTION, LLC
HARDING CONSTRUCTION LLC
HARLANCORP INC
HARMAN ELECTRIC COMPANY
HARN CONSTRUCTION COMPANY
HARPERS 1980 LLC
HARRELL HOME SERVICES INC
HARRIMANS INC
HARRIMANS INC (DAVID)
HARRISON CONSTRUCTION & DEV
HARRY H DUNHAM DBA SOUTHEAST FENCE CONTRACTING TEAM INC
HARRY VICTOR HORNAGOLD
HARRYS ELECTRICAL SERVICE INC
HARTCO INDUSTRIES
HARTSHORN CUSTOM CONTR SOUTH
HARTSHORN CUSTOM CONTRACTING
HARTSHORN CUSTOM CONTRACTOR
HARVATH HOME SVCS INC OF FL
HATCHETT CREEK ASSOCIATES, LLC
HAUL-AWAY OF THE SUNCOAST, INC.
HAWK'S NEST CONSTRUCTION INC
HAWKINS CONSTRUCTION INC
HAWKINS ELECTRIC INC
HAWKINS SERVICE COMPANY
HAY ENGINEERING LLC
HAYDEN PROFESSIONAL SERVICES
HAZELBAKER PLUMBING INC
HAZELTINE NURSERIES INC
HBS DRYWALL, LLC
HCE
HD CONSTRUCTION PROS, LLC
HD ROOFING & SOLAR LLC
HEAD ELECTIC COMPANY
HEAD MOBILE HOME SALES
HEAD MOBILE HOME SALES, INC
HEADS UP ROOFING LLC
HEALTHIER HOME SOLUTIONS, LLC
HEALTHY AC LLC
HEAPE ENTERPRISES INC
HEART OF OAK CONSTRUCTION INC
HEARTHSIDE HOMES INC
HEAT BUSTERS AC & HEATING LLC
HEATWAVE HCP LLC
HEAVEN'S BREEZE AC & HEATING
HEBERT PLUMBING CONTRACTORS
HEGI CONSTRUCTION, INC.
HEIN BROTHERS LLC
HELICAL FOUNDATIONS PLLC
HELICON
HELLER AND SPEAR INC
HEM BUILDERS SOUTH INC
HEMINGWAY HOMES & REMODELING LLC
HENDRICKS DEVELOPMENT & CONSTRUCTION LLC
HENRIQUEZ ELECTRIC CORP
HENRY PLUMBING INC
HENSON CONTRACTORS INC
HENSON DEVELOPMENT AND CONSTRUCTION INC
HERITAGE BUILDERS OF SOUTHWEST FLORIDA INC
HERITAGE COASTAL PLUMBING INC
HERITAGE GLASS INC
HERITAGE POOLS
HERNANDO FIRE & SAFETY EQUIP
HERON COVE CONSTRUCTION INC
HERON HOMES INC
HERSHBERGER ROOFING INC
HERSHMAN PLUMBING INC
HERSTON ELECTRIC
HERZOG CONTRACTORS INC
HF PLUMBING & PUMP COMPANY INC
HI
HI LOW ROOFING LLC
HI TECH CONSTRUCTION SERVICE
HI TEK ELECTRIC, LLC
HIBNER + LEVINE & ASSOCIATES
HIGH TOWER ROOFING & CONTRACTING LLC
HIGH WIND SHUTTERS
HIGHLAND CONSTR & DEVELOPMENT
HIGHLAND HEATING & AIR CONDITIONING INC
HIGHLANDER ROOFING INC
HIGHLIGHT ELECTRIC INC
HIGHPOINT INDUSTRIES LLC
HIGHTOWER INDUSTRIES LLC
HIGHWAY SAFETY DEVICES INC
HIGHWOODS CONTRACTING CORPORATION
HILDEBRAND CONSTR & REMODEL
HILL & HILL PLUMBING CO
HILL AIR CONDITIONING & HEATING LLC
HILL BRAND LLC
HILL YORK SERVICE COMPANY LLC
HILLARD BARRY CONSTRUCTION INC
HILLCO BUILDING SERVICE LLC
HILLESTAD ELECTRIC OF SW FL
HILLIARD HOMES SET UP LLC
HILMER ELECTRIC LLC
HILSCHER-CLARKE ELECTRIC COMPANY
HIMES ELECTRIC COMPANY INC
HIMES ELECTRIC COMPANY INC
HIPP INDUSTRIES INC
HIPPLE CONSTRUCTION INC
HJ FOUNDATION COMPANY
HK CONSTRUCTION GROUP, LLC
HLM CONSTRUCTION INC
HMR FABRICATION
HN BUILDER LLC
HOFF'S AIR AUTHORITY LLC
HOFFMAN ELECTRICAL LLC
HOLIDAY POOLS OF WEST FLORIDA INC
HOLLAND CONSTRUCTION CORP
HOLLAND LANDSCAPING & TREE SERVICE INC
HOLLAND PLUMBING SERVICE INC
HOLLIBAUGH CONSTRUCTION
HOLLIDAY GROUP OF SARASOTA INC
HOLMES PLUMBING INC
HOLT TRACTOR & CONSTRUCTION
HOLTON ENTERPRISES INC
HOME BUILDERS INC.
HOME CONSTRUCTION LLC
HOME CONSTRUCTION SOLUTIONS
HOME DAMAGE DOCTOR LLC
HOME IMPROVEMENT SERVICES
HOME IMPROVEMENT USA, INC
HOME INSTALL SERVICES INC
HOME LOVE CONSTRUCTION
HOME MASTERS OF VENICE INC
HOME PERFORMANCE ALLIANCE INC
HOME PRO INC
HOME PROS OF SWFL LLC
HOME TECH CONSOLIDATED INC. DBA HOME-TECH
HOME XPRTS
HOME-TECH
HOME-TECH SERVICE INC
HOMEFRONT BUILDERS LLC
HOMES BY BERNARD AND RENOVATIONS LLC
HOMES BY LAURA, INC.
HOMES DOT SOLAR LLC
HOMESMART CENTRAL INC
HOMESTEAD MAINT & IMPROVEMENT
HOMETOWN AIR CONDITIONING & SERVICES
HOMETOWN AIR CONDITIONING INC
HOMETOWN HEATING AND AIR
HOMEWISE IMPROVEMENT SOLUTIONS
HONC DESTRUCTION
HONC INDUSTRIES INC
HONDOS PLUMBING INC
HONEST A/C & HEATING LLC
HONEST AIR CONDITIONING & HEATING LLC
HONEST AIR CONDITIONING OF VENICE
HONEST LAWN AND LANDSCAPE, LLC
HONORS CONTRACTORS INC
HOOD DEPOT INTERNATIONAL INC
HOOPS ELECTRIC SERVICE INC
HOOVER PUMPING SYSTEMS CORP
HOOVER ROOFING
HORIZON BUILDERS & DEVELOPMENT INC
HORIZON COMMERCIAL ROOFING INC
HORIZON CONCRETE CONSTRUCTION
HORIZON CONSTRUCTION SERVICES
HORIZON OF SC INC
HORIZON PROPERTY MAINTANANCE MANAGEMENT
HORIZON RETAIL CONSTRUCTION INC.
HORNE CONSTRUCTION INC
HOSKINS-KRIZEN CONSTRUCTION
HOUSES BY VICKI LLC
HOW 2 GO GREEN LLC
HOWARD'S POOL SERVICE OF ENGLE
HOWARD'S POOL WORLD INC
HOWELL CONSTR SERVICE GROUP
HP STORM RESTORATION LLC
HSA ENGINEERS & SCIENTISTS
HTG - HENNESSY, LLC
HTS LLC
HUBER & ASSOCIATES
HUGHEY & ASSOCIATES CONST INC
HUMIDITY SOLUTIONS OF FLA LLC
HUMPHREY INTERIOR CONSTRUCTION
HUNSBERGER PLUMBING COMPANY
HUNTER ELECTRICAL SERVICES INC
HUNTER PLUMBING SOLUTIONS LLC
HUNTER VENTILATION AND A/C
HURRICANE GLASS SHIELD INC
HURRICANE INDUSTRIES INC
HURRICANE PROTECTION CORP
HURRICANE PROTECTION IND LLC
HURRICANE SAFETY SYSTEMS
HUSKEY CONSTRUCTION INC
HUSKEY PROPERTIES INC
HUSKY PLUMBING PROS INC
HUTCHINSON CONSTRUCTION INC
HVAC INC
HYDRA ENGINEERING & CONSTRUCTION LLC
HYPOWER INC
HYTZ ROOFING INC
I COOL INC
I.C.E. ENGINEERING, LLC
I2 VISUAL INC
IBIS CONTRACTING
IBMS INTERNATIONAL
ICON IDENTITY SOLUTIONS INC
ICONSTRUCTORS LLC
ICOOL INC
IDEAL FENCE INC
IES COMMERCIAL INC
IGGY BUILDERS LLC
IGT HOMES INC
IMAGE MASTERS OF SW FLORIDA
IMAGES GRAPHIC SPECIALTIES
IMPACT FIRE SERVICES LLC
IMPACT FIRE SERVICES LLC (FOWLER)
IMPACT FIRE SERVICES LLC (HINSBERG)
IMPACT HOMES INC
IMPERIAL DEVELOPMENT GROUP LLC
IMPERIAL ELECTRIC & A/C INC
IMPERIAL ELECTRICAL SYSTEMS
IMPERIAL ELITE PLUMBING ENT
IMPERIAL FIRE ALARM & SECURITY INC
IMPERIAL POOLS INC
IN & OUT AIR CONDITIONING
IN-EX CONSTRUCTION INC
IN-VIRONMENTAL AIR LLC
INDEPENDENT PLUMBING OF FLORIDA INC
INDEPENDENT POOL INC
INDEPENDENT SIGN AND LIGHTING LLC
INDESIGN FL LLC
INDESOL, INC.
INDIGO POOL PATIO BBQ INC
INDIGO POOL, PATIO, BBQ HOLDINGS, INC
INDUSTRIAL ELECTRICAL SYSTEMS
INDUSTRIAL REFRIGERATION SERVICES INC
INDUSTRIAL SHADEPORTS INC
INFINIMAGE CONSTRUCTION INC
INFINITE CONSTRUCTION LLC
INFINITE HOME IMPROVEMENTS INC
INFINITY AIR CONDITIONING
INFINITY CONSTRUCTION & DESIGN INC
INFINITY ENGINEERING GROUP LLC
INFINITY METAL SYSTEMS, INC
INFINITY ROOFING & SIDING INC
INFRASTRUCTURE SOLUTION SERVICES LLC
INNER LIGHT ELECTRIC INC
INNOVATE SOLUTIONS CONSTRUCTION INC
INNOVATE SOLUTIONS CONSTRUCTION INC
INNOVATIVE CONSTR OF NAPLES
INNOVATIVE CONSTRUCTION CO
INNOVATIVE CONSTRUCTION INSPECTION INC.
INNOVATIVE CONSTRUCTION OF FL
INNOVATIVE CONSTRUCTION PROS, LLC
INNOVATIVE DESIGN BUILD INC
INNOVATIVE FABRICATORS OF FL
INNOVATIVE HOMES & REMODELING INC
INNOVATIVE MARINE STRUCTURES
INNOVATIVE METAL ROOF & CONSTR
INNOVATIVE MITIGATION & RESTORATION LLC
INNOVATIVE ROOFING GROUP
INNOVATIVE SERVICE SOLUTIONS
INNOVATIVE SOLUTIONS CONSTRUCTION
INSPECTED.COM
INSPECTION SOLUTIONS LLC
INSPECTION SOLUTIONS, LLC
INSTALLATION SERVICES BY HCR LLC
INSTANT AIR CONDITIONING
INSTAR SERVICES GROUP LP
INTACT MECHANICAL SERVICES INC
INTEG MIAMI LLC
INTEGRATED FIRE & SECURITY SOLUTIONS INC
INTEGRATED TECHNOLOGEASE & SECURITY INC
INTEGRATION WIRING LLC
INTEGRITY AC LLC
INTEGRITY AIR CONDITIONING SERVICES INC
INTEGRITY AIR CONDITIONING SVC
INTEGRITY AIR LLC
INTEGRITY BUILDING SERVICES
INTEGRITY CONSTR & REMODELING
INTEGRITY CONSTRUCTION & REPAIR LLC
INTEGRITY ELECTRIC OF CHARLOTTE COUNTY LLC
INTEGRITY GROUP CONSTRUCTIONS LLC
INTEGRITY HEAT & AIR LLC
INTEGRITY HOME CONSTRUCTION INC
INTEGRITY HOME SOLUTIONS SERVICES LLC
INTEGRITY HOMES SWF LLC
INTEGRITY POOL DEVELOPMENT LLC
INTEGRITY RENOVATIONS INC
INTEGRITY ROOFING OF FLORIDA LLC
INTEGRITY ROOFING OF SOUTH FL
INTEGRITY ROOFING SOLUTIONS, LLC
INTELLIGENT PLUMBING LLC
INTERIORS UNLIMITED OF SW FL
INTERNATIONAL AIR LLC
INTERNATIONAL C & C CORPORATION DBA SIGN X-PRESS
INTERNATIONAL C&C CORPORATION DBA SIGN X-PRESS
INTERNATIONAL FIRE PROTECTION INC.
INTERNATIONAL GRAPHICS
INTERNATIONAL ROOFING LLC
INTERNATIONAL SIGN & DESIGN CORPORATION
INTERNATIONAL SIGNS & LIGHTING INC
INTERSTATE RESTORATION LLC
INTERSTRUCT TAMPA, LLC
INTEX BUILDERS, LLC
INTRA-COASTAL TUG & SALVAGE
INTRA-STATE TERRAZZO & CEMENT
INVINCIBLE ASSOCIATES INC
ION ELECTRIC LLC
IRELAND PLUMBING INC
IROK CONSTRUCTIONAL SERVICES
IRON CITY CONSTRUCTION LLC
IRON SPADE CONSTRUCTION GROUP LLC
IRONDOG INC
IROOF, LLC
IRRIGATION DESIGN ASSOCIATES
ISLAND AIR CONDITIONING INC
ISLAND BREEZE AC LLC
ISLAND STONE INTERNATIONAL
ISLANDER ELECTRIC OF SARASOTA
ISLANDWAY POOLS LLC
ITRAN PARTNERS INC
J & D ELECTRIC OF SARASOTA INC
J & H HOMES INC
J & J AIR CONDITIONING & REFRIGERA
J & M RESIDENTIAL SERVICES FLORIDA DIVISION LLC
J &J CONSTRUCTION AND DEVELOPMENT, INC
J &J CONSTRUCTION AND DEVELOPMENT, INC
J CROMPTON ELECTRIC INC
J DORSEY PLUMBING LLC
J FREDERICK CONSTRUCTION LLC
J GUNNAR NELSON CARPENTRY
J POWER ELECTRICAL SERVICE INC
J T CONSTRUCTION INC
J TAYLOR CONSTRUCTION, LLC
J&C BUILDERS LLC
J&G CARPENTRY INC
J&J FENCE INSTALLERS OF SARASOTA
J&J HOMES INC
J&J IRRIGATION SERVICES INC
J&J PLUMBING OF SARASOTA INC
J&K BUILDING & REMODELING INC
J&L REFRIGERATION & AC INC
J&L SANCHEZ INC
J&M HEATING & COOLING INC
J&S PLUMBING, INC.
J+C CONTRACTING SERVICES LLC
J. LEVI PLUMBING LLC
J.C. JONES & CO
J.F. GATOR CONSTRUCTION OF FLORIDA, LLC
J.P. SERVICES OF SARASOTA, LLC
J.R. HOBBS CO. - ATLANTA LLC
J2 SOLUTIONS INC
J2W INDUSTRIAL LLC
JA CROSON LLC
JA EDWARDS OF AMERICA, INC.
JACK FROST HVAC, LLC
JACK JOYNER HEATING & A/C COMPANY
JACK L MIDKIFF (OWNER BUILDER)
JACK LOGAN LLC
JACK'S PLUMBING LLC
JACKSON &ASSOC GEN CONTRACTORS
JACKSON BOONE, ESQ.
JACKSON POOLS INC
JACOB GILLIAM TREE CARE
JACOBSENCUSTOMBUILDERS,LLC.
JADE HOMES INC
JAM ELECTRIC SERVICE, INC.
JAMES A. LYNCH (OWNER BUILDER)
JAMES ANDERSON LLC
James Bellinder
James Bellinder
JAMES BOWLING (OWNER BUILDER)
JAMES CHRISTIAN BATES PLUMBING
JAMES E GOTCH
JAMES ELECTRIC OF TAMPA BAY
JAMES K HAFKE
JAMES K HAFKE, INDIVIDUAL
JAMES K MCSTRAVIC PLUMBING INC
JAMES O MORTON ELECTRIC CO INC
JAMES R FEID CUSTOM BLDG & REM
JAMES R HALL
JAMES ROBINSON ROOFING LLC
JAMES SAMUELS ROOFING
JAMES TALKIE CUSTOM HOMES
JAMES TIMOTHY DEANS
JAMES W KNIGHT ELECTRIC INC
JAMES W WEAVER ROOFING INC
JAMESTOWN KITCHENS, INC
JAMO BUILDING SERVICES LLC
JANKOWSKI AND ASSOCIATES INC
JANNEY RESTORATION SERVICES
JANNEY ROOFING, LLC
JANSEN & SONS INSULATION
JANSEN SHUTTERS & SPECIALITIES LTD
JANSSEN BROTHERS PLUMBING INC
JAREDJOHN ELECTRICAL CONTRACTORS
JARRED'S AIR, LLC
JAS ENTERPRISES LLC
JASON MAREK
JASON'S PLUMBING INC
JASONS PLUMBING OF SW FLORIDA INC
JASPER ALUMINUM
JAVI AIR LLC
JAYS FENCING
JB AIR CONDITIONING INC
JB CLARK CONSTRUCTION INC
JB CONSTRUCTION COMPANIES INC
JB'S STUMP & TREE SERVICE LLC
JBKENT INC
JC GENERAL CONTRACTORS LLC
JC LITTLE PLUMBING
JC PHASE ELECTRICAL CONTRACTOR INC
JC PROCRETE, LLC
JC SCHMIDT INC
JCE SERVICES OF FLORIDA INC
JCI HOME SERVICES LLC
JCIII BUILDERS LLC
JCORR LLC
JD CONTRACTING SERVICES INC
JD POOL WORKS INC
JDI ROOFING AND CONTRACTING LLC
JDM ROOFING LLC
JDP ELECTRIC INC
JE CHARLOTTE CONSTRUCTION CORP
JEA SERVICES REPAIR INC
JEDA CONSTRUCTION COMPANY
JEEC ELECTRIC
JEFF GEIGER INC
JEFF HANDLEY HTG & AIR CONDITIONING
JEFF L. SENEVEY
JEFF LONG AIR CONDITIONING INC
JEFF MASTERS ELECTRIC INC
JEFF PFOHLER ELECTRIC INC
JEFF'S COMFORT SERVICES, LLC
JEFFREY A BLETHEN (OWNER BUILDER)
JEFFREY ALLEN GEIGER
JEFFREY BISHOP (OWNER BUILDER)
JEFFREY C WAGNER (AKA GTS)
JEFFREY GRIFFITH LLC
JEFFREY L SMITH CONSTRUCTION
JEFFREY THOMAS, INC.
JEFFRIES HOMES INC
JEMSTONE CONSTRUCTION INC
JENNIE BLUME (OWNER BUILDER)
JENNINGS MOBILE HOME SETUP LLC
JEREMY K TAYLOR GENERAL CONTR
JEREMY SUTTER INC
JERMAR ELECTRIC SERVICE INC
JERRED'S AIR LLC
JERRY WILSON'S ROOFING COMPANY
JESSE HOSTETLER MASONARY LLC
JESSICA HOUNIGRINGER (OWNER BUILDER)
JFK AIR CONDITIONING INC
JFS BUILDING LLC
JGLM CONSTRUCTION SERVICES LLC
JH SULTENFUSS INC
JHM CONSTRUCTION LLC
JILLICH ELECTRIC INC
JIM ANTRIM CONSTRUCTION INC
JIM BEAR SERVICES, INC.
JIM BLANTON PLUMBING INC
JIM BYLER PLUMBING SERVICES
JIM CARPENTER DRYWALL CONSTR
JIM FRALIN HOMES LLC
JIM MCDONALD & SONS HEATING AND COOLING INC
JIM SCOTT CARPENTRY INC
JIM TROWELL APPLIANCE SERVICE
JIM'S COMPLETE CONSTRUCTION LLC
JIM'S ELECTRICAL SERVICES INC
JIMMIE LEON BURROW
JJ & D ELECTRIC, INC.
JJ & MAC OF SARASOTA LLC
JJ BEST ELECTRIC LLC
JJ HOLT CONSTRUCTION COMPANY
JJ JAMBS ELECTRICAL SERVICES
JJ QUALITY BUILDERS OF THE PALM BEACHES
JJ STATEN HOMES LLC
JJO CONSTRUCTION SOUTHEAST LLC
JK JOHNS ROOFING & SHEET METAL, INC
JK&R CONSTRUCTION INC
JKS CONSTRUCTION & ENGINEERING INC
JL ELECTRICAL SERVICE CONTRATOR CORP.
JL WALLACE INC
JM EDWARDS INC
JM PLUMBING OF CENTRAL FLORIDA LLC
JM SERVICES
JMB2 CONSTRUCTION LLC
JMC CONSTRUCTION SERVICES INC
JMD SERVICES LLC
JMI CONTRACTORS, INC.
JMORANJACKSON LLC
JNL HOME SERVICES LLC
JO-GA CORPORATION
JOE COOL A/C HEAT OF SUNCOAST
JOE YERO CONSTRUCTION LLC
JOES FAMILY PLUMBING INC
JOHN A SUITERS CONSTRUCTION
JOHN ALDEN MCGEE (OWNER BUILDER)
JOHN BURGSTINER INC
JOHN BYRD ELECTRICAL CONTRACTING LLC
JOHN CANNON CONSTRUCTION INC
JOHN CANNON HOMES INC
JOHN CONDON & ASSOCIATES INC
JOHN DACE (OWNER BUILDER)
JOHN FITZGERALD INC
JOHN GALLI, JR., INC.
JOHN GARRIS CUSTOM BUILDER, LLC
JOHN J KIRLIN INC FL DIV/DAN
JOHN J KIRLIN INC FL DIV/GREG
JOHN JACKSON ROOFING SERVICES, INC
JOHN JARVIS PLUMBING INC
JOHN LAMBETH LLC
JOHN MERRILL HOMES LLC
JOHN ODOM GENERAL CONTRACTOR
JOHN PANGBURN MARINE INC
JOHN PHILLIPS PLUMBING SERVICE
JOHN S BARNES
JOHN T FEENEY INDIVIDUAL
JOHN W CLAFFEY
JOHN W ESOLA, INDIVIDUAL
JOHN WEISS CONTRACTING CORP
JOHN WILLIAM BARKER JR
JOHN WRIGHT CONSTRUCTION CO
JOHN'S REFRIGERATION AND A/C
JOHNSON & SONS PLUMBING
JOHNSON BROS CORPORATION
JOHNSON CONSTRUCTION
JOHNSON CONTROLS FIRE PROTECTION LP
JOHNSON CONTROLS INC
JOHNSON CONTROLS SECURITY SOLUTIONS LLC
JOHNSON CONTROLS SECURITY SOLUTIONS LLC
JOHNSON ELECTRIC OF SARASOTA
JOHNSON HOMES INC
JOHNSON'S EXCAVATION & SERVICE
JOHNSON'S MECHANICAL INC
JOHNSON-LAUX CONSTRUCTION
JOHNSTON CONSTRUCTION GROUP
JON F SWIFT INC
JON MYERS ROOFING & CONSTR
JON SCHNEIDER CONSTRUCTION
JON WARMKE LIGHTING & ENERGY
JONAS YODER CONSTRUCTION GROUP
JONESN WINDOW & DOOR LLC
JOSEPH J SPORTELLI
JOSEPH P SEXTON INC
JOSH WYNNE CONSTRUCTION MGMT
JOSHUA TREE, INC.
JOY BUILDERS INC
JP ELECTRICAL SERVICES LLC
JP GENERAL CONSTRUCTION, INC.
JP JOHNSON SERVICES INC
JP O'CONNELL CONSTRUCTION INC
JPB DEVELOPMENT LLC
JPR ELECTRIC LLC
JPS PLUMBING INC
JR & CO INC
JR CONSTRUCTION GROUP LLC
JR MERRITT INC
JR PUMP SERVICE INC
JRC INC OF TENNESSEE
JSAN CORPORATION
JTS CUSTOM POOLS INC
JUAN'S PLUMBING
JUDGE ELECTRIC INC
JULIE WELLMAN (OWNER BUILDER)
JUNIPER LANDSCAPING OF FLORIDA, LLC
JUPITER-TEQUESTA A/C, PLUMBING & ELECTRI
JUST 1 CONSTRUCTION LLC
JUST CHILLIN AC & REFRIG LTD
JUST COUNTERS & OTHER STUFF
JUST KOOLIN' AIR CONDITIONING & HEATING, INC.
JVC PLUMBING SERVICE LLC
JWG BUILDERS AND PROPERTIES LLC
JWG BUILDERS AND PROPERTIES LLC (DO NOT USE)
JWM CONSTRUCTION CORPORATION
K MCDANIEL AIR CONDITIONING INC
K SIMON CONSTRUCTION, INC
K&B PUMP INC
K&K ELECTRIC INC
K2 ROOFING & SHEET METAL- FLORIDA, INC.
K2 SUMMIT, LLC
KADE CONSTRUCTION LLC
KAISER BROS HEATING & A/C INC
KAJIL PROPERTIES INC
KALEN CONST & DESIGN LLC
KALOS SERVICES INC
KANES TOTAL PLUMBING LLC
KANSAS COAST TO COAST BUILDERS
KAPPER CONTRACTING CO
KAPPES ELECTRIC CORPORATION
KAREN HAMMOND (OWNER BUILDER)
KARL KEITH KANDEL LLC
KAT CAN DO LLC
KATHY BONAT (OWNER BUILDER)
KATSY ELECTRIC INC
KB PLUMBING LLC
KBH CONSULTING INC
KCG HEATING & COOLING
KCI WIRELESS SERVICES INC
KD PLUMBING INC
KDP ELECTRIC LLC
KEEPERS OF THE CASTLE
KEITH OLSON CONSTRUCTION INC
KEITH REEVES CONSTRUCTION INC
KEL MAR CONSTRUCTION CORP
KELLOGG & KIMSEY INC
KELLY AIR SYSTEMS
KELLY BROTHERS INC
KELLY'S PLUMBING SERVICES INC
KELLYS PLUMBING
KELSEY CONSTRUCTION INC
KEMP SIGNS & SERVICE INC
KEN GATSCHENBERGER COOLING & HEATING INC
KEN HARMAR GENERAL CONTRACTOR
KEN PELLY CORPORATION
KEN TWEDT CONSTRUCTION INC
KEN TYNER ELECTRIC INC
KEN VIOLETTE INC
KEN'S HEATING & COOLING LLC
KENCO SIGN AND AWNING, LLC
KENDELL SAMPATH PLUMBING INC
KENNEDY CONSTRUCTION GROUPS LLC
KENNEDY CONTRACTORS, INC.
KENNEDY ELEC CO OF PUNTA GORDA, INC.
KENNELL PLUMBING INC
KENNETH A PERRY ELECTRIC INC
KENNETH FUHLMAN, INC
KENNETH R JAHRLING
KENNY'S A/C & HEATING SERVICES
KENNYCO CONSTRUCTION LLC
KESSELRING CORPORATION
KETROW ELECTRIC, LLC
KEVIN ALLEN BOYER
KEVIN JENKINS (OWNER BUILDER)
KEVIN SIMS
KEVIN WELSH CONTRACTING INC
KEVTAN LLC
KEY CONSTRUCTION LLC
KEY GLASS INC
KEY HONEY CONTRACTING INC
KEY ROOFING & EXTERIORS LLC
KEYCO INC
KEYSTONE WINDOWS
KEYWORTH ROOFING
KGPCO SERVICES LLC
KILOWATT ELECTRIC COMPANY
KIMAL LUMBER INSTALLED SALES INC
KIMCO CONSTRUCTION INC
KIMLEY-HORN & ASSOCIATES
KIMLEY-HORN & ASSOCIATES
KIMLEY-HORN ASSOCIATES
KIMMINS CONTRACTING CORP
KIMTIE ENTERPRISES INC
KIN CARE SERVICES INC
KIN HOME LLC
KIN-CARE SERVICES INC
KINCADE CONSTRUCTION LLC
KING ARMS CONTROLS & ELECTRIC
KING CONSTRUCTION AND REMODELING
KING CONSTRUCTION RENOVATION AND BUILDING LLC
King Engineering
KINGDOM AIRE SOLUTIONS
KINGDOM BLDRS OF TALLAHASSEE
KINGDOM COOLING AND HEATING LL
KINGDOM ROOFING SERVICES INC
KINGS OF KINGS CONSTRUCTION
KINGS ROOFING NWFL, LLC
KINGSWAY CONSTRUCTION INC
KINNEY JOHNSON FABRICATORS
KIRK BOUFFARD PLUMBING INC
KIRK THE CONTRACTOR INC
KIRKEY ROOFING INC
KIRKPLAN CONSTRUCTION INC
KIRKPLAN KITCHENS OF SARASOTA
KIRKUS AIRE INC
KIRKWOOD ELECTRIC INC
KITCHEN & BATH ON THE ISLE LLC
KITCHENALITY
KITCHENS DIRECT OF SARASOTA
KITLER HOME IMPROVEMENTS, LLC
KJH CONSTRUCTION MANAGEMENT INC
KL CONSTRUCTION LLC
KLEIN CONSTRUCTION
KLEIN ROOFING LLC
KLEIN ROOFING, PAINTING AND MORE LLC
KM CUSTOM BUILDERS INC
KMAX, LLC
KMB ROOFING, INC
KNEPP SANDRA D (TTEE)
KNIGHT BROADBAND LLC
KNIGHT ENTERPRISES
KNIGHTS AIR CONDITIONING LLC
KNIGHTS PLUMBING LLC
KNR ELECTRICAL SERVICES INC
KOALA ROOFING LLC
KOALA-TY AIR & REFRIGERATION
KOBIE COMPLETE HEATING & COOL
KOCHENDORFER ELECTRIC CORP
KODI CONTRACTING & ROOFING LLC
KOLOSVARY MANAGEMENT & CONSULTING INC.
KONSUL DEVELOPMENT LLC
KOOL CONNECTION INC
KR BROBST BUILDER LLC
KRAFT WERKS REMODELING LLC
KRAUTH CONSTRUCTION INC
KRG ELECTRIC INC
KRISTOPHER BOWYER (OWNER BUILDER)
KRUSE, COLLIN WESLEY
KS RESTORATION LLC
KSI CONSTRUCTION INC
KTMR CORPORATION DBA SARASOTA ARCHITECTURE
KTR COOLING SERVICES LLC
KUEFLER AIR CONDITIONING INC
KURT ALLEN
KURT ALLEN
KURT DOMBROWSKI ROOFING CONTR
KURTZ PLUMBING
KUSTOM INDUSTRIAL FABRICATORS
KUYKENDALL ROOFING INC
KVN HEATING & AIR CONDITIONING
KW LLC
KW MORROW & SONS ELECTRIC INC
KX4 CONSTRUCTION INC
L&L ENTERPRISES SW FLA INC
L&S IMPROVEMENTS LLC
L.C. ELECTRIC, INC.
L.E.B.S. ELECTRIC INC
LA PERAS GENERAL CONTRACTING CORP
LA ROCCA CONSTRUCTION INC.
LABRADOR ELECTRIC INC
LACKEY ROOFING INC
LACROSS COMMUNICATIONS LLC
LAGASSE PLUMBING INC (DON)
LAGASSE PLUMBING INC (MILLIGAN/ MOFFITT)
LAGASSE POOL CONST OF W FL INC
LAGASSE POOLS AND SERVICE
LAGASSE UTILITIES INC
Lags Venice LLC
LAKE ERIE ROOFING AND CONSTRUCTION INC.
LAKEWOOD RANCH TELECOMM INC
LAM MANAGEMENT INC
LAMAISON HOMES
LAMB MANAGEMENT INC. DBA LAMB TREE CARE
LAMBERT & O'NEILL REMODELING
LAMBERT CABLE SPLICING COMPANY LLC
LAMBRIGHT CONSTRUCTION
LAMNECK ELECTRIC INC
LANA'S AIR SERVICE
LANAI WINDOW ENCLOSURES, INC.
LAND ELECTRIC INC
LANDAU INC
LANDIS EXTERIOR LLC
LANDIS POOL SERVICES INC
LANE VALENTE INDUSTRIES INC
LANG IRRIGATION
LANGEDYK CONSTRUCTION LLC
LANGER ELECTRIC COMPANY
LAPENSEE PLUMBING INC
LAPORTA CONTRACTING LLC
LAPS CONCRETE SERVICES
LARCON CORPORATION
LARGO PIPING & GAS INC
LARRY PEARSON AIR CONDITIONING
LARRY WAYNE ARRASMITH
LARRY'S DRAIN AND PLUMBING LLC
LARSONS AIR CONDITIONING AND HEATING INC
LASER SERVICES INC
LATITE ROOFING & SHEET METAL
LATITE ROOFING AND SHEET METAL COMPANY
LAUMAR ROOFING SYSTEMS L.L.C.
LAUREN DANIELSON (OWNER BUILDER)
LAWRENCE GROUP
LAWRENCE LEE CONSTRUCTION SERVICES, INC.
LAWRENCE VICHICH (OWNER BUILDER)
LAYTON CONSTRUCTION COMPANY LLC
LB ELECTRIC INC
LCG ELECTRICAL CONTRACTOR COMPANY LLC
LCH ENTERPRISES OF SW FL INC
LCS ELECTRIC INC
LD TOTAL ROOFING LLC
LEAD MECHANICAL SERVICES INC
LEADERS CONSTRUCTION INC
LEAK BUSTERS ROOF REPAIRS LLC
LEAKMASTER ROOFING INC
LEBEL PLUMBING AND GAS LLC
LEDGEWOOD ROOFING & CONSTRUCTION, LLC
LEE COUNTY ELECTRIC LLC
LEE COUNTY SERVICES INC/LEE COUNTY PLUMBING ACQUISITIONS, IN
LEE DESIGNS LLC
LEE DRYWALL INC
LEE OVERHOLT CONSTRUCTION INC
LEE SQUARED INC
LEE WETHERINGTON HOMES LLC
LEECORP HOMES INC
LEEDY ELECTRIC CORP
LEESURE WATER POOLS INC
LEFT COAST BUILDERS LLC
LEFT COAST CONTRACTING INC
LEGACY ALUMINUM STRUCTURES INC
LEGACY BUILDERS ON THE WESTCOAST
LEGACY ELECTRIC LLC
LEGACY ELECTRICAL INC
LEGACY ROOFING AND CONSTRUCTION OF NFL INC
LEGACY ROOFING ON THE WESTCOAST INC.
LEGACY ROOFING SRQ
LEGACY UNITED INC.
LEGEND ROOFING CORP
LEGGETT ROOFING LLC
LEGRAND'S ROOFING LLC
LEHTO CONSTRUCTION INC
LEITNER ELECTRIC COMPANY INC
LELAND PLUMBING SOUTH INC
LEMA CONSTRUCTION & DEVELOPERS
LEMAR CONSTRUCTION INC
LEMON BAY CONSTRUCTION LLC
LEMON BAY GLASS & MIRROR
LEMON BAY HEATING & COOLING
LEN'S ROOFING INC
LENNAR HOMES LLC
LEO PFLIGER CONSTRUCTION INC
LEO ROOFING & CONSTRUCTION
LEOLA CONSTRUCTION LLC
LEONARDS ROOFING & INSULATION
LERIGO'S ELECTRIC INC
LES ROSKO CREATIVE CONSTRUCTION OF SF INC
LES SPARKS INC
LESTER KING FIRE & SAFETY
LET THERE BE LIGHT ELECTRICAL SERVICES, LLC
LET'S CHILL COOLING & HEATING LLC
LEVASSEUR BUILDING & REMODELING INC
LEVEL 4 LLC
LEVEL HEADED PROPERTIES
LEVEL ONE INC
LEVI COOPER MECHANICAL CONTR
LEW & SONS PLUMBING
LEWIS ROOFING
LF WOLF CONTRACTING INC
LGCY INSTALLATION SERVICES, LLC
LGM ELECTRICAL CONTRACTOR LLC
LGM HOMES INC
LGT RESTORATION SERVICES, INC
LIBERTY ALUMINUM COMPANY
LIBERTY ELECTRIC
LIBERTY PLUMBING & SEPTIC
LIBERTY R&V CONSTRUCTION
LIFESAFETY MANAGEMENT INC
LIFESTYLE EXTERIOR PRODUCTS
LIFESTYLE REMODELING
LIFESTYLES DEVELOPMENT GROUP, LLC
LIFETIME METAL AND TILE ROOFING, LLC
LIFETIME ROOFING SPECIALISTS INC
LIFETIME ROOFS & CONSULTING
LIGHT LIFE LLC
LIGHT LINE ELECTRIC INC
LIGHTHOUSE ELECTRIC OF SARASOTA
LIGHTHOUSE HOMES INC
LIGHTHOUSE RENOVATION & CONSTR
LIGHTNER CONSTRUCTION, LLC
LIGHTNING ALUMINUM INC
LIGHTSPEED CONSTRUCTION GROUP LLC
LILLEY AIR CONDITIONING INC
LIN R ROGERS ELECTRICAL
LINCOLN HOMES INC
LINDA SUN
LINEAR ROOFING & GENERAL CONTRACTORS LLC
LINGO ELECTRIC INC
LINING & COATING SOLUTIONS LLC
LIPTON WINDOW AND DOOR
LITTLE COCONUT HOMES, INC
LITTLEFIELD ELECTRIC INC
LIVING WATER ENTERPRISES INC
LIVINGSTON ELECTRIC OF CHARLOTTE COUNTY INC
LJ SILVA CONSTRUCTION LLC
LK DESIGN GROUP
LLOYD ROOFING, INC.
LM REMODELING AND CONSTRUCTION
LMC BUILDERS INC
LMG CONSTRUCTION & DEVELOPMENT
LOCAL CONTRACTOR LLC
LOCAL FLO PLUMBING LLC
LOCAL ONE GC, LLC
LOCKE CONSTRUCTION INC
LOFNO ELECTRIC LLC
LOFTIN PLUMBING LLC
LOGAN PLUMBING INC
LONE STAR ELECTRICAL SERVICES LLC
LONG HOME PRODUCTS
LONG HOME PRODUCTS- GRIFFITH
LONGBOAT KEY BUILDERS INC
LONGBOAT KEY ROOFING INC
LORD CHESTERFIELD CONSTRUCTION
LORNIC CUSTOM CONTRACTORS LLC
LOTT SIGN SERVICE
LOUIS MORRELLO CONSTRUCTION
LOUIS SORRENTINO CONSTRUCTION
LOUVAT PLUMBING SERVCE LLC
LOVE YOUR BATH LLC
LOVES AIR CONDITIONING & HEAT
LOWES HOME CENTERS LLC
LR SIMMONS PLUMBING INC
LRE FOUNDATION REPAIR, LLC.
LSCI INC
LSJ CONSTRUCTION INC
LSW BUILDERS INC
LT PLUMBING LLC
LUCAS BUILDERS INC
LUCAS LAGOONS CONSTRUCTION LLC
LUCAS LAGOONS INC
LUCHO WATERWORKS, INC
LUCIEN PELLETIER
LUDWIG VOLKSHEIMER ROOFING INC
LUMINOUS ELECTRIC
LUMIO HX INC
LUMPERT ELECTRIC SERVICE LLC
LUMSDEN BUILDING & DESIGN LLC
LUNEX POWER INC.
LUTZ ELECTRIC SERVICE INC
LUXURY BATH SYSTEMS
LUXURY HOME BUILDERS INC
LVI ENVIRONMENTAL SERVICES INC
LYKINS SIGNTEK & DEVELOPMENT SPECIALTIES INC
LYNN TITUS INC
LYNNE FLEMING (OWNER BUILDER)
LYON CONSULTING LLC
M AND J CONTRACTING INC
M ELLIS ELECTRICAL INC
M SPACE HOLDINGS LLC
M&J CONSTRUCTION AND DEVELOPER
M&M CONSTRUCION OF SO FL
M&S ROOFING CO INC
M&T MECHANICAL LLC
M. A. CONSTRUCTION GROUP, LLC
M.R. FENCE
M/I HOMES OF FT.MYERS/NAPLES, LLC
MA UNTCH ENTERPRISES
MABRY BROTHERS, INC.
MACIAS PLUMBING INC
MACK RENICK PLUMBING INC
MACKSEY CONSTRUCTION COMPANY INC
MACKSEY ELECTRIC INC
MACLEOD BUILDERS INC
MACLOUD A/C & REFRIGERATION SERVICES LLC
MADISON INDUSTRIES INC OF GA
MAESTRO CONTRACTORS, INC
MAGEE SIGN SERVICE INC
MAGLICH HOMES OF SARASOTA LLC
MAGNIFICENT AIR LLC
MAGNUM AIR LLC
MAGNUM BUILDERS OF SARASOTA INC
MAGNUM ROOFING AND RESTORATION
MAGRALOGIC INC
MAGRETTA CONSTRUCTION REMODEL
MAHKYN CONTRACTING INC
MAHLE COOL AIR & HEATING
MAHOGANY ROOFING INC
MAIN COMMERCIAL COOKING/REFRIG
MAIN GATE ENTERPRISES INC
MAIN GATE ENTERPRISES INC
Main Street Renewal - Tampa 2701 W Busch Blvd Ste 118,
MAINLEY PLUMBING CO, INC.
MAINTENX
MAINTENX INTERNATIONAL SERVICE MANAGEMENT GROUP INC
MAIO BUILDING AND LAND DEVELOPMENT LLC
MAJ CONTRACTING, INC
MAJESTIC CUSTOM POOLS INC
MAJOR LEAGUE PLUMBING & HOME SERVICES LLC
MAJORS ELECTRICAL SERVICES LLC
MAK ELECTRIC LLC
MAKO HOMES LLC
MAKO PLUMBING INC
MALCOLMSON CONSTRUCTION CO
MALPHUS AND SON GENERAL CONTRACTORS INC
MANASOTA COMMERCIAL CONSTRUCTI
MANASOTA COOLING & HEATING LLC
MANASOTA ELECTRIC INC
MANASOTA POOLS LLC
MANASOTA ROOFING INC
MANASOTA WHOLESALE WINDOW & DOOR INC
MANATEE AIR HEATING & COOLING INC
MANATEE ELECTRIC INC
MANATEE ROOFING INC
MANEELY, PAUL CUPP
MANHATTAN CONSTRUCTION CO
MANNING BUILDERS LLC
MANNING PLUMBING
MANNS ELECTRIC CORP
MANSON ROOFING INC
MAR-LIN QUALITY FINISHES INC
MARAND BUILDERS INC
MARATHON AIR HEATING & COOLING
MARC JONES CONSTRUCTION LLC D/B/A SUNPRO SOLAR
MARINA UTILITIES INC
MARINE CONTRACTING GROUP INC
MARINO CONSTRUCTION ENGINEERING, INC
MARINO PLUMBING INC
MARIOS PAINTING OF SOUTH FL
Marisol Bemis
MARK & SON CONSTRUCTION INC
MARK BLEWETT EXCAVATING INC
MARK BROWER CONSTRUCTION INC
MARK CALVERT ALUMINUM LLC
MARK HOTCHKISS (OWNER BUILDER)
MARK KAUFMAN ROOFING
MARK KAUFMAN ROOFING CONTR INC
MARK KIMBEL INC
MARK P RADER (OWNER BUILDER)
MARK PORTER CONSTRUCTION INC
MARK REED BUILDERS INC
MARK TAYLOR CONSTRUCTION LLC
MARK WILLIAMS CONSTRUCTION COMPANY INC
MARLIN JAMES INC
MARQUEZ BUILDERS GROUP, LLC
MARRA CONSTRUCTION, INC
MARRERO'S ELECTRIC LLC
MARTIN A/C & REFRIGERATION
MARTIN AIR OF SW FL INC
MARTIN ALUMINUM SERVICE
MARTIN CHRISTOPHER VULJOIN, INDIVIDUAL
MARTIN DALE KNARR
MARTIN GLOVER (OWNER BUILDER)
MARTIN RUANE CONSTRUCTION CO
MARTIN SEPTIC SERVICE
MARTUSCELLI MASONRY & RESCREEN
MARULA CONSTRUCTION LLC
MARY WELLENDORFF (OWNER BUILDER)
MARYANN CUNNEEN (OWNER BUILDER)
MASADA HOMES INC
MASCO CABINETRY LLC
Maslar Renovation & Design, LLC
MASON HOMES INC
MASSEY CONSTRUCTION GROUP, INC.
MASSEY CONTRACTING LLC
MASSFLO PLUMBING INC
MASSING ENTERPRISES
MASSING ENTERPRISES INC
MASTEC NETWORK SOLUTIONS LLC
MASTER BUILT ROOFING
MASTER CONSTRUCTION TEAM LLC
MASTER CRAFT HOME SERVICES OF FL, INC
MASTER CRAFT PLUMBING INC
MASTER PAVING ENGINEERING LLC
MASTER PLUMBERS
MASTER SERVICE OF SWF
MASTERCRAFT ROOFING
MASTERPIECE POOLS
MASTERWORK STUDIOS INC
MATHEIS ELECTRIC, LLC
MATHUR & GERDES INC
MATNEY & MAIO CONSTRUCTION SERVICES, LLC
MATRIARCA BUILDERS INC
MATRIX ELECTRIC INC
MATT HUNTER PLUMBING INC
MATT TROUTMAN CONSTRUCTION LLC
MATT'S ELECTRIC INC
MATTCO MODULAR SERVICE LLC
MATTHEW SEKOSKY (OWNER BUILDER)
MATTHEW SIMS (OWNER BUILDER)
MATTHEWS GIBRALTAR MAUSOLEUM & CONSTRUCTION
MATTHEWS ROOFING LLC
MAVERICK CONSTRUCTION LLC
MAVERICK CONSTRUCTION LLC
MAXIMIZED PLUMBING & DRAINS LLC
MAXIMUM CONNECTIONS INC
MAXWELL URETHANE ROOFING INC
MAY CUSTOM HOME
MAY PLUMBING COMPANY INC
MAYFAIR DEVELOPMENT GROUP INC
MAYFIELD CONSTRUCTION INC
MBA ASSOCIATES INC
MBK CONSTRUCTION INC
MC DEAN INC
MC ELECTRIC CO
MCALLISTER GENERAL CONTRACTOR
MCCALL CONTRACTING FL LLC
MCCOMBER ELECTRIC INC
MCCORMICK SINGLE PLY & ROOFING
MCDANIEL FIRE PROTECTION
MCDONALD DEANTHONY CONSOLIDATE
MCE YODER ROOFING LLC
MCENANY ROOFING INC
MCGEE CORPORATION
MCGRAW CONSTRUCTION INC
MCGUIRE ELECTRIC INC
MCINTYRE CONSTRUCTION SERVICES
MCINTYRE ELWELL & STRAMMER GENERAL CONTRACTORS INC
MCKENZIE CONTRACTING, LLC
MCKENZIE STRUCTURES INC
MCLAY MOBILE HOMES
MCLEOD CONSTRUCTION LLC
MCLEOD GENERAL TRADES LLC
MCLEOD LAND SERVICES INC
MCMULLEN AIR CONDITIONING REFR
MCNATT PLUMBING COMPANY INC
MCNEILL SIGNS INC
MCQUAID ENTERPRISES OF FL INC
MDK ELECTRIC LLC
MEARES PLUMBING INC
MEARES PLUMBING INC
MEC-TECH HEATING AND A/C
MECHANICAL INC
MECHANICAL ONE, LLC
MECHANICAL SERVS OF CENTRAL FL
MECHANICOOL SERVICE COMPANY
MEDIA RESOURCES USA INC
MEDIC AIR SYSTEMS INC
MEGRAM CONSTRUCTION CO.
MEISNER ELECTRIC, INC
MEJIA TELECOMMUNICATIONS CO
MELCO ELECTRIC INC
MENEMSHA DEVELOPMENT GROUP INC
MERAKI INSTALLERS LLC
MERCHCO SERVICES, INC.
MERCURY AIR HEATING & AIR CONDITIONING
MERIDIAN COMFORT LLC
MERIDIAN ELECTRICAL SERVICES INC
MERIDIEM CONSTRUCTION SERVICES, INC
MERIT ELECTRIC CO INC
MERITAGE HOMES OF FLORIDA INC
MERRIGAN BUILDING GROUP LLC
MERRILLS HEATING & AIR CONDITIONING INC
MESKEL AND ASSOCIATES ENGINEERING
MESSINA CONSTRUCTION INC
MESSINA ELECTRIC LLC
MESSINA POOLS LLC
METALSBETTER ROOFING & SHEET METAL INC
METRO ELECTRIC LLC
METRO GARAGE DOOR OF SARASOTA
METRO MECHANICAL SYSTEMS INC
METRO ONE FIRE PROTECTION SVC
METRO R F SERVICES, INC.
METROPOLE CONSTRUCTION INC
METROPOLITAN CONSTRUCTION MGMT
METZ ELECTRIC INC
MEYER EQUIPMENT MANAGEMENT
MG ELECTRICAL DEVELOPERS, INC.
MGM ELECTRIC INC
MGO CONTRACTING, LLC
MGQ & ASSOCIATES, INC
MHC GC LLC
MHI ROOFING FLORIDA LLC
MHP RENOVATIONS INC
MICHAEL A CISTARO LLC
MICHAEL A ROSS INC
MICHAEL DETO DRYWALL
MICHAEL J LOONEY INC
MICHAEL K WALKER & ASSOC INC
MICHAEL KING (PERMIT SERVICE)
MICHAEL MANNING ROOFING SERVICES LLC
MICHAEL SOMMERS MASONRY INC
MICHAEL W ALCORN
MID COAST ROOFING INC
MID FLORIDA CONTRACTING, INC.
MID FLORIDA REFRIGERATION INC
MID PINELLAS AC & HEATING INC
MID-COUNTY ROOFING INC
MID-FLORIDA ROOFING
MIDWAY SERVICES INC
MIDWEST BUILDERS INC
MIDWEST MEASURES LLC
MIDWEST QUALITY CONSTRUCTION
MIGHTY DOG ROOFING SWFL
MIGHTY DOG ROOFING-SWFL
MIKE DOUGLASS AIR CONDITIONING
MIKE DOUGLASS PLUMBING INC
MIKE HODGE, LLC.
MIKE MULLIGAN PLUMBING SERVICE
MIKE RITCHIE REFRIGERATION INC
MIKE ROMECKI ELECTRIC
MIKE SOMMERS MASONRY INC
MIKE VON STETINA PLUMBING
MIKE'S AC SOLUTIONS, LLC
MIKES PLUMBING LLC
MILAN THE PLUMBER LLC
MILBAR CONSTRUCTION AND ROOFING INC
MILLENIUM A/C & REFIGERATION
MILLENNIA ROOFING SOLUTIONS
MILLENNIUM CONSTR SARASOTA CTY
MILLER CONSTRUCTION OF SARASOTA CO INC
MILLER ELECTRIC
MILLER ELECTRIC COMPANY
MILLER ELECTRIC FL
MILLER SECURITY GROUP
MILLER SEWER AND DRAIN FL INC
MILLERS COASTLINE ELECTRIC, LLC
MILLERS' COASTLINE CONSTRUCTION
MILLERS' COASTLINE PLUMBING
MILLSTONE CONCRETE & MASONRY LLC
MILORAD PUDJA PLUMBING LLC
MINSHALL ENTERPROSE CONSTRUCTION SERVICES LLC
MIRADECKS INC
MIRAGE ENTERPRISES INC
MIRASOL FAFCO SOLAR INC
MIRBEC INC EAGLE FIRE & SAFETY
MIRO SERVICES
MISSION PLUMBING & HOME REPAIR LLC
MISTER BEST ROOF INC
MISTER EXTERIOR INC
MISTER SPARKY (DUNEDIN) CONDOS
MISTER SPARKY (SRQ)
MISTER WINDOW
MITCHELL AND SONS ROOFING LLC
MITO PLUMBING CORP
MIZPAH INTEGRATIONS, INC
MJ HARRIS INC
MJCN ELETRICAL CONTRACTOR INC.
MJK CONSTRUCTION INC
MJM ELECTRIC INC
MJR ELECTRIC
MJS CONSTRUCTION SERVICES INC
MK CONSTRUCTION GROUP, LLC
MLK TOP CONTRACTING GROUP, INC.
MLR ELECTRIC INC
MMR DEVELOPMENT CORP
MOBILE AIR INC
MOD-ZEN CONSTRUCTION LLC
MODEL CITY ROOFING
MODEL CONSTRUCTION CORP
MODERN AIR & REFRIGERATION
MODERN CONCEPTS IAQ INC
MODERN ELECTRIC
MODERN MECHANICAL SERVICES LLC
MODERN SERVICE FOR HOME & BUS
MODERN SERVICES
MODERN WORLD BUILDERS, LLC
MOLLY GODOY- HOMEOWNER
MOMENTUM AC SERVICES INC
MOMENTUM SOLAR
MONARCH PLUMBING INC
MONARCH PRINTING & DESIGN
MONOPOLY PROPERTIES LLC
MONROE PLUMBING INC
MONSTER AIR & HEAT LLC
MONTGOMERY AIR CONDITIONING & HEATING SERVICES INC
MOORECORP ROOFING, INC
MOR-SPORTS GROUP, INC.
MORA & ORTIZ GENERAL CONTRACTOR INC
MORGAN AIR CONDITIONING LLC
MORGAN CONSTRUCTION SERVICES
MORGAN EXTERIORS WINDOWS SIDING DOORS & MORE LLC
MORI BUILDING & DESIGN GROUP
MORI BUILDING & DESIGN GROUP, INC
MORRISON ALUMINUM CONSTRUCTION
MOSS & ASSOCIATES LLC
MOUNT VERNON REALTY CO INC
MOUNTAIN AIR SRQ
MOUNTAINEER ELECTRIC LLC
MOURA GENERAL CONSTRUCTION INC
MPS DEVELOPMENT & CONSTRUCTION LLC
MR AC COOLING AND HEATING INC
MR BUILD GENERAL CONTRACTOR
MR BUILD INC
MR ELECTRIC
MR ELECTRIC OF SARASOTA
MR ELECTRIC OF SOUTHWEST FLORIDA
MR ROOTER PLUMBING
MR ROOTER PLUMBING OF TAMPA BA
MR. ELECTRIC OF SARASOTA
MRT LAWN SERVICE INC
MS CONSULTANTS INC
MSB SERVICES, LLC
MTD CUSTOM BUILDING INC
MTS AIR CONDITIONING SERVICES, LLC
MTS CONSTRUCTION INC
MULLETS ALUMINUM PRODUCTS INC
MULTIMAX SYSTEMS LLC
MUNYAN COATINGS EAST, INC
MUNYAN ROOFING SERVICES, LLC
MURDOCH DESIGN & CONSTRUCTION SERVICES
MURDOCK ELECTRIC INC
MURPHY ELECTRIC INC
MURPHY'S ROOFING
MURTON ROOFING CORP
MUSTANG BUILDERS INC
MVM CUSTOM HOMES INC
MVP CONTRACTORS
MY GREEN BUILDINGS INC
MY MECHANICAL INC
MYAKKA HEATING & COOLING
MYCO-TEK RESTORATION INC
N&B CONSTRUCTION INC
N.C.N. ELECTRIC INC
NAKOMA CONSTRUCTION INC
NANCO CONSTRUCTION LLC
NAPLES FIRE SPRINKLER INC
NASSAU ELECTRIC CORPORATION
NASTAR ROOFING
NATHAN TYLOR LLC
NATIONAL BATH, INC.
NATIONAL ELECTRIC CONTRACTING
NATIONAL HOMECRAFT OF BREVARD
NATIONAL ROOFING OF COLLIER
NATIONAL SALVAGE & SERVICE
NATIONS AIR CONDITIONING
Nations Roofing, Construction & Mechanical, LLC
NATIVE AIR CONDITIONING, LLC
NATIVE HOME IMPROVEMENTS INC
NATIVE PLUMBING & DRAIN LLC
NATIVE SUN POOLS AND SPAS INC
NATURE COAST HOME SOLUTIONS LLC
NAUTILUS CUSTOM HOMES INC
NAUTILUS POOLS PCFL INC
NAVCO SECURITY SYSTEMS
NCC CONSTRUCTION INC
NEAL COMMUNITIES OF SOUTHWEST FLORIDA LLC
NEAL SIGNATURE HOMES
NEELY SRQ LLC
NEIEL GROUP LLC
NELA ELECTRIC INC
NELSON J WILSON
NELZCO REMODELING INC
NESTOR ALFONSO PLUMBING INC
NETCOM SERVICES INC
NETO ENERGY LLC
NETWORK ELECTRICAL CONTRACTOR LLC
NEUMANN CONSTRUCTION & ROOFING, LLC
NEVES CONSTRUCTION SERVICES
NEW CONCEPTS CONSTRUCTION
NEW CREEK BUILDERS INC
NEW DAWN ELECTRIC
NEW FLORIDA POOLS, INC
NEW IMAGE ROOFING LLC
NEW LIFE BUILDING GROUP INC
NEW LIFE PLUMBING LLC
NEW PASS DOCK AND SEAWALL LLC
NEW ROOFS GROUP LLC
NEW VISION PLUMBING & MECHANIC
NEW WAVE CONSTRUCTION INC
NEW WAVE ROOFING LLC DBA WEILER ROOFING
NEW-TECH CONSTRUCTION
NEWCO CONSTRUCTION OF AMERICA
NEWSOUTH WINDOW SOLUTIONS LLC
NEWTON REMODELING INC
NEXT DIMENSION CONSTRUCTION INC.
NEXT DOOR RENO, LLC
NEXT ERA RENOVATIONS
NEXT GRC LLC
NEXT LEVEL PLUMBING INC
NEXT PLUMBING
NEXTECH
NIALVI LLC
NICE AIR LLC
NICHOLS CONTRACTING INC
NLTL LLC
NNI CONSTRUCTION CO
NO SWEAT COOLING & HEATING INC
NO-BOB'S ELECTRIC INC
NOBILITY INSPECTIONS, LLC
NOBLE AIR CONDITIONING SYSTEMS
NOBLE CONSTR & DEVELOPMENT INC
NOBLES PLANT CONSTRUCTION & UNDERGROUND
NODAL CONSTRUCTION & ELECTRIC ASSOCIATES INC
NOLAND'S ROOFING
NOLANDS ROOFING INC
NORBERG ELECTRIC INC
NORDIC PLUMBING LLC
NORMAN ALEXANDER
NORMAN E FRECHETTE JR
NORMAN FRECHETTE JR
NORRIS & SAMON PUMP SERVICE
NORSTAR Development USA - Brian Evjen
NORTH COUNTY PLUMBING
NORTH END PLUMBING AND DRAINS LLC
NORTH FLORIDA FIELD SERVICES
NORTH PORT ELECTRIC SERVICE
NORTH PORT GLASS AND MIRROR
NORTH PORT SUNCOAST TILE INC
NORTH RIVER PLUMBING & GAS WORKS LLC
NORTHERN AIR HEAT & REFRIG INC
NORTHERN ELECTRICAL CONTRACTOR
NORTHERN PRECISION INC
NORTHERN QUALITY CONSTRUCTION
NORTHVALE INC
NORTHWIND COOLING LLC
NOTTINGHAM PLUMBING AND WATER SOLUTIONS INC
NOTTINGHAM SOLUTIONS LLC
NOVA CONSTRUCTION & ROOFING
NOVA ENGINEERING AND ENVIRONMENTAL, LLC
NOVA ENTERPRISES OF SW FL INC
NPP ENTERPRISES INC
NRP CONTRACTORS II LLC
NSQUARE INC
NU ELECTRIC CO
NU FLOW AMERICA INC
NU VISION AC LLC
NU-IMAGE CLAIMS INC
NU-SONS ELECTRIC INC
NU-TEC ROOFING CONTRACTORS INC
NULINE BUILDING SYSTEMS INC
NUMEN CONSTRUCTION INC
NUTEK PLUMBING LLC
NUTTER CUSTOM CONSTRUCTION LLC
NV POOLS LLC
NW SIGN INDUSTRIES OF FL INC
NYMAN NATIONAL INC
O' DONNELL CONSTRUCTION CO
O'CONNOR CONSTRUCTION GROUP LLC
O'DONNELL CONSTRUCTION COMPANY
OAKHURST SIGNS
OAKHURST SIGNS
OAKHURST SIGNS
OASIS ENGINEERING LLC
OBERLIN CONSTRUCTION INC
OCEAN AIR CONDITIONING OF SOUTHWEST FLORIDA INC
OCEAN AIRE CONDITIONING INC
OCEAN BUILDERS OF SW FLORIDA
OCEAN CONSTRUCTION & PLUMBING LLC
OCEAN GROUP CONSTRUCTION INC
OCEAN QUALITY ROOFING INC
OCEAN ROOFING INC
OCEAN ROOFING OF FL LLC
OCEAN VIEW CONSTRUCTION, INC
OCEAN WIRE ELECTRIC INC
OG LIVING LLC
OGDEN BROTHERS CONSTRUCTION INC
OGDEN BROTHERS CONSTRUCTION LLC
OLD FLORIDA HOMES LLC
OLDE FLORIDA ELECTRIC LLC
OLDE WORLD ARTISANS INC
OLIMPIYUK LLC
OLIVERI ARCHITECTS
OLIVIERI CONSTRUCTION INC
OLSEN ROOFING INC
OLSON & GOUTHRO DEMO & EXCAV
OLSON PLUMBING LLC
OLYMPUS POOLS, INC
OMEGA DISASTERS CLEANUP AND ROOFING LLC
OMEGA GARAGE DOORS INC
OMEGA REFRIGERATION & HVAC
OMKAL CONSTRUCTION INC
OMNI EYE INC
ON A MISSION REMODELING
ON POINT CONSTRUCTION SERVICES INC
ON POINT PLUMBING LLC
ON TOP ROOFING & REMODEL
ON TRACK DOORS
ON-LINE ELECTRIC
ONE CALL CONSTRUCTION SERVICES
ONE HOUR AIR CONDITIONING & HEATING
ONE STOP AIR MECHANICAL CORP
ONE STOP COOLING AND HEATING T
ONE STOP ROOFING INC
ONECO PLUMBING INC
ONERESTORE, LLC
ONINTU CONSTRUCTION INC
ONPOWER SERVICES INC
ONYX DEVELOPMENT GROUP
ONYX PLUMBING LLC
OPIFEX ELECTRIC INC
OPRR INC (OLYMPIC POOLS)
OPTIMA CONSTRUCTION GROUP LLC
OPTIMUM ROOFING LLC
OPTIMUS ENERGY SOLUTIONS
ORANGE BLOSSOM ROOFING, LLC
ORANGE STATE INDUSTRIES
ORANGEWOOD BUILDERS INC
ORBE CONSTRUCTION INC
ORBIT ENERGY & POWER LLC
ORIGINAL SIGNS LLC
ORION CONTRACTING W COAST DIV
ORLIE'S PLUMBING LLC
OSCAR & SON ELECTRIC INC
OSORIO PLUMBING LLC
OSPREY CONSTR OF HILLSBOROUGH
OTERO-COSSIO CONSTRUCTION, LLC
OTIS ELEVATOR COMPANY
OTIS JOINER ROOFING CONTRACTOR INC
OUTDOOR IMAGES INC
OVERALL MARINE SERVICES LLC
OVERHEAD DOOR CO OF SARASOTA INC
OVERLAND CONTRACTING INC
OVERLAND CONTRACTING INC
OVERLAND CONTRACTING INC ELEC
OWEN-AMES-KIMBALL CO
OWENS CONSTRUCTION AND INSPECTION SERVICES, LLC
OWINGS CONSTRUCTION LLC
OWNER / BLDR:DENISE CLERICUZI0
OZARK ROOFING AND CONSTRUCTION LLC
P
P & D AIR CONDITIONING & HEATING, INC.
P & M GENERAL CONSTRUCTION INC
P&A ENTERPRISES INC
P&D AIR CONDITIONING & HEATING
P&G CONSTRUCTION OF SARASOTA
P&R PRO COATINGS INC
P&R RENOVATIONS & INTERIORS
PAC & MORE INC
PACE ROOFING INC
PAGE MECHANICAL GROUP LLC
PALERMO CONSTRUCTION ASSOC
PALEVEDA PLUMBING LLC
PALM COAST ROOFING INC
PALM CONSTRUCTION CONSULTANTS
PALM HARBOR CONSTRUCTION
PALM ISLAND ELECTRIC INC
PALM PLUMBING
PALM RIVER ELECTRIC INC
PALMER BUILDERS
PALMER CONSTRUCTION SERVICES
PALMETTO SOLAR, LLC
PAMELA A MACFARLANE (OWNER BUILDER)
PANE PROTECTION HURRICANE
PAPER CHASE PERMIT SERVICE
PAPU ELECTRIC INC
PARADISE AIR CONDITIONING INC
PARADISE BAY BUILDERS INC
PARADISE CUSTOM BLDRS OF SW FL
PARADISE EXTERIORS LLC
PARADISE EXTERIORS ROOFING LLC
PARADISE GENERAL CONTRACTING LLC
PARADISE HOME BLDRS OF SW FL
PARADISE KITCHENS SRQ INC
PARADISE LAWN AND TREE SERVICE
PARADISE OF SARASOTA INC
PARADISE PLUMBING LLC
PARADISE PROJEXX CONTRACTING AND CONSTRUCTION LLC
PARADISE ROOFING INC
PARADISE STONEWORKS, INC.
PARAGON ELECTRIC SERVICES INC
PARAGON ELECTRIC SYSTEMS INC
PARAGON INSTALLATIONS, INC.
PARAMOUNT PAINTING & SERVICES
PARAMOUNT POOLS OF PINELLAS
PARKER WALTER GROUP INC
PARKING LOT SERVICES
PARKS AIR CONDITIONING, INC
PARKS CONTRACTING SERVICE INC
PARLAMENT ROOFING & CONST
PARRISH HEATING & COOLING, INC
PASADENA PLUMBING INC
PASQUALE ROMANO LLC
PAT CARLTON CONSTRUCTION INC
PAT COOK CONSTRUCTION INC
PATCHETT CONSTRUCTION INC
PATEK INSPECTIONS LLC
PATIO ENCLOSURES
PATNODE ROOFING INC
PATRIARCH SECURITY SYSTEMS LLC
PATRICA CAROTHERS (OWNER BUILDER)
PATRICK SAMION LLC
PATRICKAIR LLC
PATRICKS ELECTRIC COMPANY
PATRIOT AIR LLC
PATRIOT CONSTRUCTION SERVICES LLC
PATRIOT HOME IMPROVEMENT
PATRIOT PLUMBING CORP
PATRIOT TECHNOLOGIES PLUMBING
PAUL DAVIS RESTOR/SEMINOLE CTY
PAUL DAVIS RESTORATION OF SARASOTA AND CHARLOTTE COUNTIES
PAUL DEAO ROOFING INC
PAUL E BOLLENBACH ROOFING
PAUL F LONGVAL
PAUL HIGGINS PLUMBING INC
PAUL HORSCHEL & SON INC
PAUL J SIERRA CONSTRUCTION
PAUL KIEFER ELECTRIC INC
PAUL MARCUM CONSTRUCTION LLC
PAUL SHERMA PE PROFESSIONAL ENGINEERING RESOURCES INC
PAUL VOUGHT ALUMINUM INC
PAUL W WILSON PLUMBING INC
PAULL CONSTRUCTION INC
PAVER LANDSCAPES INC
PAW MATERIALS INC
PCI CUSTOM HOMES
PCS CORPORATION
PDF ROOFING LLC
PDG ELECTRIC COMPANY
PEACE RIVER AIR
PEACH STATE ROOFING INC
PEACOCK CONSTRUCTION & REMODEL
PEAK ELECTRICAL, INC
PEARL POOL PLASTERING, LLC
PEARLS POOL CARE INC
PEDRICK POOLS
PEERLESS FOREMOST FENCE
PEERLESS RESTORATION & CONSTRUCTION LLC
PEGASUS GENERAL CONTRACTORS, INC
PELICAN AIRE COMMERICAL SERVICE INC
PELICAN DEVELOPMENT GROUP LLC
PELICAN HOME BUILDERS INC
PELICAN ROOFING FL
PELLA WINDOWS & DOORS
PELOQUIN CONSTRUCTION CO INC
PEMBERTON BUILDING INC
PEMBROKE ELECTRIC INC
PENGUIN AIR COOLING & HEATING
PENINSULA CONSTRUCTION INC
PENINSULAR MECHANICAL CONTRACTORS INC
PENN ENVIRONMENTAL SERVICES
PENN MECHANICAL INC
PEOPLES GAS REPAIR INC
PERCO GENERAL CONTRACTORS
PEREZ HOMES INC.
PEREZ TILE AND CONSTRUCTION COMPANY INC
PERFECT AIR OF SARASOTA LLC
PERFECT TEMP AIR LLC
PERFECT WEATHER A/C & REFRIGERATION OF FLORIDA INC
PERFECTION POOL & PATIO INC
PERFORMANCE AIR INC.
PERFORMANCE CONTRACTING LLC
PERFORMANCE ELECTRIC LLC
PERFORMANCE ELECTRICAL SERVICE
PERFORMANCE EXTERIORS INC
PERFORMANCE PLUMBING SOLUTIONS LLC
PERFORMANCE ROOFING LLC
PERINOVIC & ALBRECHT ELECTRICAL SERVICES INC
PERKINS GC LLC
PERMA ROOF CONTRACTORS INC
PERMACAST LLC
PERMIT SERVICE, INC
PERRONE CONSTRUCTION
PERRY CONCRETE OF VENICE INC
PERRY HOMES
PERRY HOMES INC
PERRY ROOFING INC
PERRY STEVENS MOBILEHOME SETUP
PETE LASHLEY PLUMBING INC
PETER BORG CONSTRUCTION INC
PETER J TAVINO JR PEPC, INC
PETER LERICHE
PETER'S REMODELING INC
PETERSENDEAN ROOFING AND SOLAR
PETERSON HOMES INC
PETROLEUM & CONSTRUCTION SERV
PETROLEUM MARINE CONSTRUCTION LLC
PETROLEUM MARINE LLC
PETROLEUM TECHNICIANS INC
PEYTON CONTRACTING & CONST INC
PF CONSTRUCTION LLC
PGA LLC
PGR MECHANICAL CONTRACTORS INC
PHD ELECTRIC LLC
PHIL MAGILL ELECTRIC INC
PHIL PHILLIPS CONSTRUCTION INC
PHILIP E JOHNSON INC
PHILLIPS CONTRACTING INC
PHILLIPS, TODD R.
PHOENIX BUILDERS OF WEST FLORI
PHOENIX CONSTRUCTION & DESIGN
PHOENIX LANDING INC.
PHOENIX PRO MANAGEMENT INC
PIED PIPER PLUMBING INC
PIERCE AIR CORPORATION
PIERCE CONTRACTING INC
PIERCE, HEIDI
PIKE GAS SERVICES, LLC
PIKE TELECOM AND RENEWABLES, LLC
PILE RESTORATION & DECK RESURF
PILEGGI CUSTOM HOMES
PILLAR TO POST PROFESSIONAL HOME INSPECTION
PILZ AND SONS ELECTRIC, LLC
PINCH A PENNY #10
PINCH A PENNY #184
PINE HILLS LANDSCAPING INC
PINECREST CONSTRUCTION INC
PINELLAS COMFORT SYSTEMS
PINNACLE AIR SOLUTIONS, LLC
PINNACLE BUILDING CORP
PINNACLE CONSTRUCTION INC OF IOWA
PINNACLE CONSTRUCTION OF SW FLORIDA LLC
PINOS AIR CONDITIONING & HEATING LLC
PINPOINT PLUMBING AND GAS LLC
PIONEER BUILDING & DEVELOPMENT
PIONEER PLUMBING OF SARASOTA LLC
PIPE RESTORATION SOLUTIONS INC
PIPE RITE FIRE SPRINKLERS INC
PIPE WRIGHT
PIPEDEX PLUMBING LLC
PIPEDREAM PLUMBING OF SW FL INC
PIPEFLOW PLUMBING LLC
PIPER ELECTRICAL SERVICES
PIPER FIRE PROTECTION INC
PITCH PERFECT ROOFING LLC
PITTMAN CONSTRUCTION
PJ HAYES INC
PJ ROOFING, INC
PJ'S ALUMINUM INC
PJM DEVELOPMENT CONCEPTS INC
PJWD ENERGY LLC
PK TOTAL PLUMBING, LLC
PLANNED PLUMBING LLC
PLATINUM ELECTRIC INC
PLATINUM POOLS SRQ
PLATINUM ROOFING & CONSTRUCTION LLC
PLATINUM SOLAR HOMES INC
PLAY SPACE SERVICES INC
PLAZA MAINTENANCE PLUS INC
PLEASANT LIGHTSCAPES INC
PLS CONSTRUCTION
PLUMB CRAZY OF FLORIDA LLC
PLUMBCO PLUMBING SOLUTIONS
PLUMBER JOHN INC
PLUMBING 411, CORP.
PLUMBING BY HART
PLUMBING DOCTOR II INC
PLUMBING EMPIRE, INC.
PLUMBING EXPRESS INC
PLUMBING IN PARADISE LLC
PLUMBING KING LLC
PLUMBING SERVICES OF CHARLOTTE
PLUMBING SOLUTIONS OF SOUTHWEST FLORIDA LLC
PLUMBING TODAY
PLUMBMERICA
PLUMBOSS INC
PLUMEX PLUMBING LLC
PLUNKETT RAYSICH ARCHITECTS LLP
PLYMEL HOMES INC
PMR ELECTRICAL CONTRACTOR LLC
PMS PETROLEUM MAINT & SERVICE
POE ROOFING & CONSULTING INC
Point Break Survey, LLC
POINT SERVICES AIR CONDITIONING LLC
Point-by-Point Construction, LLC
POLAR BEAR AIR LLC
POLAR BEAR COOLING & HEATING LLC
POLAR BEAR COOLING AND HEATING
POLAR BEAR SERVICES LLC
POLAR BREEZE CO
POLK ROOFS LLC
POLKHOVSKI SERVICES LLC
POLO BUILDERS INC
POLUSA CONSTRUCTION CORP
POOL CENTURION GROUP LLC
POOL CREATIONS
POOL DESIGN CONCEPTS
POOL HEROES
POOL ONE PLASTERING DIVISION
POOL TROOPERS
POOLE & KENT COMPANY OF FLA
POOLMASTERS OF SOUTHWEST FL
POOLS BY BRADY INC
POOLS BY DESIGN FL, LLC
POOLS BY JOAN BROWN INC
POOLS BY LAGASSE INC
POOLS BY LAGASSE INC (INACTIVE)
POOLS BY POOL PRO INC
POPA CONSTRUCTION SERVICES INC
POPA POOLS & SPAS
POPE BUILDERS LLC
POPPA CONSTRUCTION INC
PORT'S POWER ELECTRIC INC
PORTALP USA INC
PORTER CONTRACTING INC
PORTER ELECTRIC LLC
POSEIDON PLUMBING LLC
POSEIDON ROOFING LLC
POSPIECH CONTRACTING INC
POSSEBON & POZZOBON COMPANY LLC
POU-JAC INC
POWELL, KEVIN THOMAS
POWER & LIGHT
POWER AIR CONDITIONING INC
POWER COMM LLC
POWER DESIGN INC
POWER ELECTRIC SERVICES INC
POWER HOME REMODELING GROUP LLC
POWER MOVES ELECTRIC LLC
POWER PRODUCTION MANAGEMENT
POWER SUPPORT PARTNERS
POWER TECHNOLOGY SERVICES LLC
POWER UP ELECTRIC SERVICES LLC
POWERBLOCK BUILDERS INC
POWERCORE SERVICES LLC
POWERHOUSE RETAIL SERVICES LLC
POWERSECURE INC
POWERWORKS ELECTRIC INC
POZZIE CONSTRUCTION INC
PRACTICAL PLUMBING LLC
PRATTCO INC
PRECAST WALL SYSTEMS INC
PRECISE CONSTRUCTION INC
PRECISE CONSTRUCTION SERVICE
PRECISION ALUMINUM AND REMODELING INC
PRECISION AUTOMATIC SPRINKLER
PRECISION CLIMATE SOLUTIONS LLC
PRECISION CONTRACTING OF FLORIDA LLC.
PRECISION CUSTOM HOMES INC
PRECISION DOOR SERVICE
PRECISION ELECTRIC INC
PRECISION FIRE SYSTEMS INC
PRECISION GATE & SECURITY, INC
PRECISION HOME BUILDERS LLC
PRECISION LOCATORS
PRECISION MARINE CONSTRUCTION
PRECISION PERMITS
PRECISION PLUMBING OF SWFL, LLC
PRECISION PLUMBING SERVICES
PRECON CORPORATION
PREFAB PLUMBING INC
PREFERRED DRILLING SOLUTIONS, INC.
PREFERRED PAVERS & CONCRETE
PREMIER AIR COND & REFRIGERATION INC
PREMIER ALUMINUM
PREMIER BATHROOMS
PREMIER COMMUNITIES INC
PREMIER CONSTRUCTION CONTRACTORS
PREMIER ELECTRIC
PREMIER FIRE SPRINKLERS INC
PREMIER LIGHTING LLC
PREMIER OUTDOOR LIVING & DESIG
PREMIER PLUMBERS LLC
PREMIER PLUMBING OF SW FL INC
PREMIER POOLS & SPAS
PREMIER POOLS OF SW FLA INC
PREMIER PROPERTY DEVELOPMENT
PREMIER SECURITY SERVICES INC
PREMIER SERVICES
PREMIERE BUILDERS
PREMISES CABLING SYSTEMS INC
PREMIUM AIR SOLUTIONS INC
PREMIUM ROOFING & RESTORATION LLC
PRES & SONS MH TRANS & SERVICE
PRESTIA PLUMBING INC
PRESTIGE GUNITE INC
PRESTIGE HOMES
PRESTIGE METAL ROOFING INC.
PRESTIGE PLUMBING & AIR LLC
PRESTIGE PLUMBING & RESTORATION
PRESTIGE PLUMBING AND HOME SERVICES, INC
PRESTIGE WALL SYSTEMS INC
PRESTO AIR LLC
PREVENTATIVE HOME MAINTENANCE
PRICE ELECTRIC
PRICE MECHANICAL INC
PRICELESS HOME IMPROVEMENTS, INC.
PRIDDY ELECTRIC LLC
PRIDE ROOFING SERVICES
PRIDE STUCCO AND PLASTERING
PRIMA CONSTRUCTION
PRIMA DEVELOPERS & CONSTR
PRIMARY ELECTRIC OF SW FL
PRIME AIR CONDITIONING AND REFRIGERATION INC
PRIME HVAC SERVICES LLC
PRIME S & R INC
PRIMO POOLS & SPAS BY MARIO LLC
PRIORITY AIR AND HEAT INC
PRIORITY ELECTRIC CONTRACTOR INC
PRIORITY INSPECTION NOW LLC
PRIORITY PERMITTING SERVICES
PRISM CONTRACTORS INC
PRISMA SIGNS AND DISPLAYS
PRISTINE GUTTERS LLC
PRISTINE POOL SERVICES OF SW FL INC
PRISTINE ROOFS LLC
PRITCHARD AIR CONDITIONING
PRITCHARD CONSTRUCTION
PRIVATE PROVIDERS OF SOUTHWEST FLORIDA
PRO 1 ALARM
PRO A/C AND ELECTRIC
PRO A/C AND ELECTRIC
PRO A/C PLUMBING AND ELECTRIC
PRO AUDIO SERVICES INC
PRO BUILD INC
PRO CIRCUIT ELECTRICAL
PRO ELECTRICAL SERVICES INC
PRO PLUMBING LLC
PRO PLUMBING SERVICES, CORP.
PRO RESTORATION & CONSTRUCTION, LLC
PRO ROOFING SERVICES OF FL
PRO-MARK RETAIL SERVICES, INC
PRO-PLUMBING WORKS LLC / THE DRAIN PROS
PRO-ROOFING USA LLC
PRO-TEC ELECTRIC LLC
PRO-TEC POWER SOLUTIONS
PRO-TEC POWER SOLUTIONS
PRO-TECH A/C AND HEATING SVC
PRO-TECH ROOFING OF BREVARD
PRO-TECH STORM SYSTEMS INC
PRO1 ALARM
PROCON INC
PROCORE ELECTRIC INC
PROCRAFT EXTERIORS INC.
PRODUCTION MANAGEMENT ASSOCIATES INC
PROFESSIONAL CHOICE CONSTR INC
PROFESSIONAL CONST OF SARASOTA
PROFESSIONAL ELECTRICAL SERVICES INC
PROFESSIONAL ENGINEERING RESOURCES INC
PROFESSIONAL GLASS
PROFESSIONAL HEATING & COOLING SERVICE INC
PROFESSIONAL PLUMBING & DESIGN
PROFICIENT PLUMBING, LLC
PROFORMANCE ROOFING
PROGRESSIVE POOL REPAIR
PROLINE CONSTRUCTION INC
PROLINE GENERAL CONTRACTOR INC
PROMISE CONSTRUCTION GROUP LLC
PROMISE ELECTRICAL SERVICES
PROMPT GARAGE DOOR SERVICE INC
PROPANE WORKS LLC
PROPUNCH OF FLORIDA INC
PROQUEST INC
PROROOFER INC
PROSHUTTERS INC
PROSOLAR GROUP LLC
PROTEK PLUMBING & DRAIN SPEC
PROTEK PROPERTY SOLUTIONS, INC
PROTOCOL COMMUNICATIONS AND DATA INC
PROTON ELECTRIC SERVICE LLC
PROVIDENT COS INC
PROVIDENTIAL ROOFING AND CONSTRUCTION INC.
PROVOST CONSTRUCTION & SONS LLC
PS CONSTRUCTION INC
PSG PLUMBING SERVICE INC
PULLEN CONSTRUCTION GROUP
PUNTA GORDA PLUMBING COMPANY
PURE PLUMBING OF SW FL INC
PURIFIED AIR CONDITIONING INC
PURR-FECT AIR INC
PUTNAM MECHANICAL, LLC
PUTNAM, DAN & BETH
PWD-ORLANDO LLC
PYD ELECTRIC CORP
PYE-BARKER FIRE & SAFETY LLC (ALARM)
PYE-BARKER FIRE & SAFETY LLC (SUPRESSION)
PYRAMID CONSTRUCTION OF SW FL
QP CONSTRUCTION INC
QT CONSTRUCTION
QUALI TILE ROOFING INC
QUALITY AIR CONDITIONING CO
QUALITY BROTHERS CARPENTRY INC
QUALITY CONTROL AIR INC
QUALITY ELECTRIC
QUALITY ENTERPRISES USA INC
QUALITY FIRST ELECTRIC SW FLORIDA CORPORATION
QUALITY IN PROPANE, LLC
QUALITY MECHANICAL PLUMBING
QUALITY PLUMBING BY KELLY CARDIN
QUALITY PLUS ELECTRIC INC
QUALITY POOLS & SPAS INC
QUALITY ROOFING & SHEET METAL OF CFL
QUALITY ROOFING INC
QUALITY SCREENING WINDOW AND DOOR INC
QUALITY WALLS ENTERPRISES INC
QUALITY WIRE WORKS LLC
QUAMEC CORP
QUANTUM CONSTRUCTION & CONTRACTING LLC
QUE SOLUTIONS INC
QUESTAR CONSTRUCTION INC
QUICK A/C, LLC
QUICK COOL LLC
QUICK RESPONSE FIRE PROTECTION
QUICK ROOFING LLC
QUICKSILVER ELECTRIC INC
QUINCO SERVICES INC
R & L BUILDING CONSTRUCTION INC
R & S PLUMBING, LLC
R & S PROFESSIONAL ENGINEERING
R CARR INC
R D JOHNSON CONSTRUCTION INC
R E KLUCK BUILDERS LLC
R WEBBER INC
R&R ELECTRIC OF GULF COAST LLC
R&R ELECTRIC OF SARASOTA INC
R&R HEATING & COOLING INC
R&R PERMITTING LLC
R&R PLUMBING AND HEATING INC
R2 ELECTRIC LLC
R3 CONSTRUCTION LLC
R3 GROUP CGC LLC
RABER CONSTRUCTION
RACK ELECTRIC
RAG ELECTRIC LLC
RAILCO INC
RAIMONDI PLUMBING LLC
RAIN PROOF ROOFING & CONTRACTING LLC
RAINBOW CONSTRUCTION CO OF SRQ
RAINBOW ELE CO OF MARYLAND INC
RAINSCAPE INC
RAM CONSTRUCTION MGMT. INC.
RAM ELECTRIC INC
RAM GENERAL CONTRACTING & DEVELOPMENT, INC
RAM JACK FOUNDATION REPAIR
RAM MARINE SERVICES INC
RAMATE INC
RAMATE INC
RAMCON LLC
RAMON HOMES AND REMODELING LLC
RAMPART HOMES INC
RAMS ROOFING LLC
RAMSAY GAS SOLUTIONS LLC
RANDALL MECHANICAL INC
RANDALL MULLINS CONSTRUCTION
RANDALL SHROCK CONSTRUCTION
RANDAZZO BUILDERS INC
RANDOLPH ROBINSON CEO INC
RANDY HIGEL LLC
RANDY MASK PLUMBING INC
RANDY MASK PLUMBING INC DBA M&M GAS SERVICES
RANDY MULDOON INC
RANDY RUSHING PLUMBING LLC
RANGER AMERICAN OF FLORIDA INC
RANON INC
RAPID RESPONSE AC SERVICES, INC
RAPID SECURITY SOLUTIONS LLC
RARIDON CONSTRUCTION, LLC
RASHELLE R CROFUT
RAT ROD PLUMBING INC
RAUCCI CONSTRUCTION INC
RAV A BILT CONSTRUCTION INC
RAV CHI LLC
RAY ALLEN ELECTRIC SERVICE INC
RAY C. MOORE LLC
RAY CONTRACTING INC
RAY'S PLUMBING
RAYCO ELECTRIC INC
RAYNOR REFRIGERATION INC
RAZE SOLAR INC.
RAZERELLI ELECTRIC
RB OWENS ELECTRIC
RBS CONSTRUCTION LLC
RBT INDUSTRIAL ELECTRIC INC
RC ELECTRIC SERVICE INC
RCS & COMPANY INC
RD LANGE CONSTRUCTION INC
RDC
RDI COMMERCIAL & RESIDENTIAL SVC
RE CRAWFORD CONSTRUCTION LLC
RE CURRAN INC
RE JOHNSON & SON INC
RE JOHNSON ELECTRICAL
RE-BATH OF SOUTHWEST FLORIDA
RE-BATH OF THE BAY
READY NATION CONTRACTORS, INC.
REAL ESTATE MAKEOVER CO LLC
REAMS HOME SERVICES LLC
RECON SERVICES GROUP, LLC
RECONSTRUCTION EXPERTS, INC.
RED ARCHITECTURE PLANNING
RED CARPET AC & HEATING
RED DOGS ROOFING OF FL INC
RED DOT ROOFING LLC
RED LADDER ROOFING, LLC
RED RHINO PLUMBING
RED ROCK BUILDERS INC
RED TRUCK CONSTRUCTION GROUP LLC
RED TRUCK ROOFING, LLC
REDDING CONSTRUCTION GROUP
REDONE HOMES LLC
REDWIRE
REDWOOD HOMES INC
REECE BUILDERS WINDOWS INC
REED BUILDERS INC
REEDER'S LANDSCAPING INC
REEDY ROOFING LLC
REEF TROPICAL POOLS
REFINED BY DESIGN LLC
REFINED REMODELING INC
REFINED ROOFING
REGAL ELECTRIC INC
REGAL ENTERPRISES
REGION SOLAR, LLC
REGIS CONSTRUCTION
REGIUS CONSTRUCTION LLC
REI TECHNOLOGY SOUTHEAST LLC
REITER ELECTRIC INC
RELIABLE IRRIGATION SYSTEMS INC
RELIABLE PLUMBING SERVICES CORP
RELIABLE POOL LLC
RELIABLE POWER SYSTEMS
RELIABLE SHUTTER COMPANY INC
RELIABLE SPRINKLER SYSTEMS INC
RELIABLE WELL SERVICES
RELIANCE AIR SERVICES, INC
RELIANT FIRE SYSTEMS, INC
RELLIM CONTRACTING LLC
REMCO BUILDERS, INC.
REMI COMPANIES
RENAISSANCE POOLS OF SOUTHWEST FLORIDA INC
RENCH'S COOLING & HEATING
RENDITIONS
RENE J GENEST (OWNER BUILDER)
RENEW RESTORATION INC.
RENEWABLE BUILDING SOLUTIONS
RENEWABLE ENERGY MATTERS INC
RENEWAL BY ANDERSEN OF FLA
RENEWAL BY ANDERSEN OF FLA-SELLERS
RENEWPRO ROOFING, LLC
RENO POWER INC
RENOVATION SRQ INC
RENT-A-HUSBAND ROOFING CO
REPLACE MY CAGE LLC
RESCUE AIR COOLING AND HEATING LLC
RESCUE ROOFING OF TAMPA INC.
RESIDENTIAL RESORTS
RESIDENTIAL SERVICES, INC.
RESILIENT CONTRACTING LLC
RESIST ALL SYSTEMS INC
RESOLUTE ROOFING LLC
RESTAURANT & INSTITUTIONAL SVC
RESTOCON CORPORATION
RESTORE MASTERS CONTRACTING, LLC
RESTORSURANCES SERVICES
RESULTS BUILDERS INC
RESURRECTION POOLS LLC
RETRO ROOFING, LLC
REVIVE ROOFING AND CONSTRUCTION LLC
REVLIS CONSTRUCTION INC
REVYS CONSTRUCTION LLC
REYNA AIR CONDITIONING HEATING
REYNOLDS VENTURES INC
RF MITCHELL WINDOWS & DOORS
RG CONSTRUCTION INC
RGA DESIGN LLC
RGMBF ENTERPRISES INC
RH SCREEN, LLC
RHINO CRETE INC
RHODES BUILDING & REMODELING
RHODUS REMODELING & CONSTRUCTION INC
RHYNE RESTORATION
RIC'S ECLECTIC ENTERPRISE CORP
RICCIO'S PLUMBING INC
RICH GAGNE CONSTRUCTION INC
RICHARD & RICE CONSTRUCTION CO
RICHARD A TRAPP BUILDER LLC
RICHARD H MARTIN ROOFING
RICHARD RAYBORN MOBILE HOME
RICHARD'S PLUMBING AND ELECTRICAL
RICHARD'S PLUMBING REPAIR INC
RICHARDSON FLOORCOVERING CO
RICHCO RESIDENTIAL CORP
RICHLAND CONSTRUCTION LLC
RICK FLATHER (PERMIT SERVICE)
RICK THE ROOFER INC
RIDGE MAX ROOFING INC
RIDGE TOP EXTERIORS LLC
RIDGE VALLEY EXTERIORS, INC
RIDGELINE CONSTRUCTION HSV, INC
RIETH PLUMBING LLC
RIGGS CONSTRUCTION CO INC
RIGHT WAY ELECTRIC LLC
RIGHT WAY ROOFING
RIKER CONSTRUCTION SERVICES, LLC
RILEY ROOFING LLC
RIM EXPRESS, INC.
RIMSHOT CONSTRUCTION INC
RINEHART HOMES
RINKER MATERIALS CORP
RISE UP PLUMBING
RISING STAR PAVERS
RISING STAR ROOFING LLC
RIST CONSTRUCTION INC
RISTOW ROOFING LLC
RITE-FLO PLUMBING CO TAMPA
RITZ CONSTRUCTION CORP INC
RITZCRAFT POOLS AND PAVERS INC
RITZMAN TENNIS COURTS
RIVA CONSTRUCTION INC
RIVERA & COMPANY CORP
RIVERBANK CONSTRUCTION LLC
RJ LABADIE CONSTRUCTION INC
RJ MAHAFFEY CONSTRUCTION
RJ MARTIN NATIONAL CONTRACTING
RJ VANN MECHANICAL CORP
RJJM LLC DBA ALLEGRA HOMES
RJM SOLUTIONS INC
RJS ENTERPRISES OF MANATEE INC
RK SCHMIDT & ASSOCIATES
RKD CONSTRUCTION INC
RL "BOB" HOWARD GENERAL CONTR
RL ANDERSON INC
RL ANDERSON INC (JAMES)
RL ANDERSON INC (JOHN)
RL BUILDING CONTRACTORS INC
RL CONCRETE INC
RL JAMES INC
RL SPENCER ROOFING LLC
RL TEEL LLC
RLH CONSTRUCTION LLC
RM COATS CONSTRUCTION INC
RM YOUNG CONSTRUCTION INC
RML CONTRACTING SERVICES LLC
ROAD RUNNER HIGHWAY SIGNS INC
ROARK SOLAR LLC
ROBBY'S CONCRETE INC
ROBERT CHARLES INC
ROBERT CORSI (OWNER BUILDER)
ROBERT E HUGUES ENTERPRISES
ROBERT G. KANE (OWNER BUILDER)
ROBERT KINARD INC
ROBERT L WILSON LLC
ROBERT MALLORY ROOFING INC
ROBERT MARKEL INC
ROBERT MCGUIRK ELECTRICAL
ROBERT O SINCLAIR III LLC
ROBERT S CHRISTLIEB ENTERPRISE
ROBERT S JENSEN (OWNER BUILDER)
ROBERT SANDERS ELECTRIC INC
ROBERTS BROTHERS CONSTRUCTION INC
ROBERTS HVAC & REFRIGERATION INC
ROBERTSON FENCE
ROBIN BOWERS ROOFING LLC
ROBIN BUILDERS INC
ROBINSON ROOFING & RESTORATION LLC
ROBINSONS ALUMINUM CONSTRUCTION INC
ROBSON CORPORATION
ROCK CASTLE ROOFING, INC
ROCK HOMES INC
ROCKSTONE CONSULTING LLC
ROCKTIDE CONSTRUCTION
ROCKWELL BUILDING SYSTEMS LLC
ROCKWELL CONTRACTING INC
ROCO TECHNOLOGY CORP
RODAN FIRE SPRINKLERS INC
RODCO INC
RODMAN ROOFING INC
ROESCH HOUSEMOVERS INC
ROG ELECTRIC INC
ROGER ELECTRIC LLC
ROGERS SIGN CORP
ROH MECHANICAL LLC
ROHALEY & SONS PLUMBING CONTRACTORS INC
ROI CONSTRUCTION
ROKOS STUCCO & MASONRY INC
ROLL-A-WAY STORM & SECURITY
ROLLADEN INC
ROLLSECURE SHUTTERS INC
ROLLSHIELD LLC
ROLSAFE INTERNATIONAL CORP
ROLSAFE LLC
ROMAN & SONS BUILDING AND REMODELING LLC
ROMAN PLUMBING INC
ROMAN ROOFING INC
ROMAN'S SERVICE LLC
ROMANO BROTHERS ROOFING
ROMINES ELECTRIC INC
ROMTECH THERMAL CONTROLS
RON HORN PLUMBING INC
RON S ADAMS
RON SCHULZ INC
RON SERGENTS ELECTRIC INC
RON VOIT CONSTRUCTION LLC
RON-L-ALUMINUM INC
RONALD L SMITH INC
RONALD LEE CHOVAN INDIVIDUAL
RONALD R PERKINS INC
RONALD R PERKINS INC
RONALD SPANG INC
RONALD W MORGAN INC
RONALD'S PLUMBING LLC
RONNIE W WEBB
RONNIES MANUFACTURED HOMES INC
ROOF ARMY OF FLORIDA LLC
ROOF COMMANDER, INC.
ROOF DOCTORS LLC
ROOF DOCTORS XPERTS
ROOF EZ INC
ROOF FOR LIFE LLC
ROOF LEAK PATROL INC
ROOF MONKEYS LLC
ROOF PROS STORM DIVISION, INC.
ROOF REPAIR NEAR ME
ROOF REVOLUTION, INC
ROOF RIGHT
ROOF RX
ROOF SARASOTA LLC
ROOF SOLDIER, LLC
ROOF SYSTEMS INC
ROOF TILE SPECIALISTS LLC
ROOF WARS LLC
ROOFCLAIM.COM LLC
ROOFCRAFTERS ROOFING LLC
ROOFIN RON INC
ROOFING & RECONSTRUCTION CONTRACTORS OF AMERICA LLC
ROOFING & RENOVATION OF FLA
ROOFING BROTHERS OF FLORIDA LLC
ROOFING BY CURRY
ROOFING BY HOMEPLUS
ROOFING BY PROS, INC.
ROOFING SOLUTIONS UNLIMITED LLC
ROOFING SOURCE
ROOFING10X INC
ROOFIX TECHNOLOGIES LLC
ROOFLINES SOUTH INC
ROOFROOF.NET INC
ROOFS FOR EVERYONE LLC
ROOFS FOR LIFE INC
ROOFS ONLY FL INC
ROOFTECH ROOFING & WATERPROOFING INC
ROOFTOP ROOFING IN
ROOSTER ROOFING LLC
ROSARIO ELECTRIC LLC
ROSECORP INC
ROSKOVENSKY CONSTRUCTION INC
ROSS ELECTRIC SOLUTIONS INC
ROSS PLUMBING
ROTH BROTHERS OF FLORIDA INC
ROTH ELECTRIC
ROTO-ROOTER
ROTO-TECH PLUMBING CONTRACTORS LLC
ROWE MITCHELL CONSTRUCTION CO
ROY J SCHLEMAN PLUMBING CO
ROYAL AIR CONDITIONING & HEATING INC
ROYAL CONSTRUCTION & DESIGN
ROYAL PALM CONSTRUCTION INACTIVE
ROYAL PALM CONSTRUCTION SERVICES, LLC
ROYAL PALM HOME BUILDERS INC
ROYAL PALM HOMES LLC
ROYAL POOLSCAPES POOL AND SPA, INC
ROYAL REMODELING & DESIGN INC
ROYALTY CONSTRUCTION INC
ROYALTY ROOFING USA LLC
RPM PLUMBING, LLC
RR RESTORATION OF GEORGIA LLC
RSA PLUMBING LLC
RSG PLUMBING LLC
RT MOORE CO INC
RTR ELECTRICAL SERVICES INC
RUD CONSTRUCTION, LLC
RUSAW PLUMBING INC
RUSH ROOFING INC
RUSS' PLUMBING SERVICE INC
RUSSELL AND SONS CONTRACTING LLC
RUSTY PLUMBING CO INC
RUTH ANN DEARYBURY
RW ELECTRICAL SERVICES LLC
RWL COMMUNICATIONS INC
RX RENOVATIONS XPERTS LLC
RYAN COMPANIES US INC
RYAN COOLING CORP
RYAN'S PLUMBING LLC
RYBIN ENTERPRISES LLC
RYDER CONTRACTING & DESIGN LLC
RYMAN CONSTRUCTION INC
S & E RENOVATIONS INC
S SQUARED ELECTRIC LLC
S&B MARINE ENGINEERING INC
S&B SCREENING & ALUMINUM INC
S&L ISLAND INVESTMENTS, DBA GLASS OF MARCO
S&N FENCE
S&S ELECTRIC COMPANY INC
S&S GAS SYSTEMS INC
S&S PLUMBING INC
S.E.R.L.L. ELECTRIC, INC.
S.T. ENERGY SERVICES, LLC
S7 SOLAR
SABAL CONSTRUCTION AND ROOFING LLC
SABRE COMMUNICATIONS
SAC WIRELESS, LLC
SACKETT PLUMBING INC
SAFARI HOME SERVICES, LLC
SAFE AND SOUND ROOFING LLC
SAFE STEP WALK IN TUB CO
SAFE STREETS USA LLC
SAFE ZONE LLC
SAFEHOUSE SECURITY SOLUTIONS
SAFETY FIRST TECHNOLOGIES, INC.
SAFETY SIGNAL SYSTEMS INC
SAGE HOMES LLC
SAI INC
SAILFISH COMMUNICATIONS INC
SAINT PAULS ROOFING LLC
SAL CONTRACTOR LLC
SAL ELECTRIC SERVICE INC
SALCO SCREENS INC
SALDANA ROOFING
SAM FENCING AND SECURITY
SAM PLETCHER ELECTRIC
SAM POTTER ELECTRICAL CONTR
SAM W MCCLESKEY CONSTRUCTION CO INC
SAMAR ROOFING, LLC
SAMS
SAMS ELECTRIC CONTRACTORS INC
SANDER & SONS ROOFING LLC
SANDOVAL'S TOTAL COMFORT LLC
SANDS ENGINEERING, LLC
SANDS EXTERIOR DESIGNS INC
SANDY BEACH CONSTRUCTION LLC
SANFORD PLUMBING INC
SANTOS COLON JR. EXPERT WATER REMOVAL
SANTOS PLUMBING LLC
SANTOS USA CONSTRUCTION
SAPP ELECTRIC INC
SAPUTO & ASSOCIATES INC
SARASOTA AIR & HEAT LLC
SARASOTA ALARM & ELECTRIC
SARASOTA ALARM & ELECTRIC INC
SARASOTA ALARM & FIRE ELECTRON
SARASOTA CONSTR & REMODELING
SARASOTA CONSTRUCTION INC
SARASOTA CONSTRUCTION SERVICES LLC
SARASOTA ELECTRIC CORP DBA FIRE BRIGADE ALARM SYSTEMS
SARASOTA GLASS & MIRROR INC
SARASOTA REMODELING AND DESIGN LLC
SARASOTA REMODELING INC
SARASOTA RESTAURANT EQUIPMENT
SARASOTA ROOFING COMPANY INC
SARASOTA SHUTTER
SARASOTA SHUTTERS LLC
SARRETT CORPORATION
SARTY'S ROOFING INC
SARVER CONTRACTING LLC
SASH & SILL LLC
SASI CONTRACTING, INC
SAVE ON ENTERPRISES OF SARASOTA COUNTY
SAWTOOTH LICENSED CONSTRUCTION LLC
SAXMAN ENTERPRIZES INC
SB360 LLC
SC CONTRACTORS LLC
SCARBROUGH SARASOTA INC
SCARPINATO ENTERPRISES INC
SCG FIELDS LLC
SCHAPPACHER ENGINEERING, LLC
SCHENKEL & SHULTZ INC
SCHERER CONSTR & ENGR OF W FL
SCHIPPERS MARINE CONSTRUCTION
SCHLABACH ELECTRIC LLC
SCHMEHL & HARKNESS INC
SCHMIDT, JOHN L INDVIVIDUAL
SCHNELL CONTRACTORS INC
SCHRADER CONTRACTING SERVICES
SCHULTE CONSTRUCTION CO INC
SCHULTZ ELECTRICAL CONTRACTORS
SCHUTZ CONTRACTING LLC
SCHWARTZ AIR CONDITIONING AND HEATING LLC
SCHWARTZ POOLS
SCOPE SERVICES INC
SCOTT CONSTRUCTION ASSOCIATES
SCOTT LEWIS CONSTRUCTION INC
SCOTT SERVICES
SCOTT WARRAM LLC
SCOTT'S SCREENS OF SOUTH FL IN
SCOTTY O HOME REPAIR & MAINT
SCOUT SERVICES
SCREEN FACTORY FLORIDA LLC
SCREENCO INC
SCREENMASTERS OF SARASOTA
SCREENS BY MARVIN LLC
SCRIBBS ALUMINUM ENCLOSURE LLC
SCRIBNER CONTRACTING OF SOUTH FLORIDA, INC
SDM CONSULTING INC
SEA RAY ELECTRIC
SEA TURTLE SOLAR SYSTEMS LLC
SEABERG BUILDERS INC
SEABREEZE AC INC
SEABREEZE ELECTRIC INC
SEACOAST BUILDING & DESIGN LLC
SEALCOAT SYSTEMS INC
SEAMENT CONCRETE PUMPING LLC
SEAN MCCUTCHEONS AIR CONDITIONING AND HEATING INC
SEAN OBRIEN INC
SEAN PATRICK ENTERPRISES
SEAN REILLY PLUMBING
SEARS HOME IMPROVEMENT PRODUCTS
SEASHELL CONSTRUCTION LLC
SEASHORE PLUMBING, INC.
SEASONAL AIR INC
SECURITAS TECHNOLOGY CORPORATION
SECURITY ALARM CORPORATION
SECURITY VAULT WORKS, INC
SEERS INC
SEIBOLD SECURITY
SEL SECURITY INC
SELECTRIC INC
SELLERS ALUMINUM INC
SELLS ALUMINUM & CONSTRUCTION
SEM POWER LLC
SEMINOLE HEIGHTS ROOFING, LLC
SENA-TECH LLC
SENECK CONSTRUCTION COMPANY
SENN ELECTRICAL SERVICES INC
SENNES DESIGN BUILD, LLC
SENTRY METALS LLC
SERED VENICE 41, INC.
SERGEANTS ELECTRIC LLC
SERVICE AMERICA ENTERPRISE INC
SERVICE AMERICA NETWORK
SERVICE EXPERTS HEATING & A/C
SERVICE EXPERTS LLC FT MYERS
SERVICE MEDICS LLC
SERVICE STAR COOLING & HEATING
SERVICE STAR ENTERPRISE INC
SERVICE WORKS COMMERCIAL ROOF
SERVICE WORKS OF FT LAUDERDALE LLC
SERVICE WORKS OF TAMPA INC
SERVICEMASTER BY WRIGHT
SERVICEMASTER PLUMBING SERVICES
SERVPRO OF VENICE
SETH E BELL LLC
SEVEN BRIDGES CONSTRUCTION CO
SF ROOFING QUEST LLC
SFC SERVICES CORP
SFR SERVICES L.L.C.
SHADDAI HL PLUMBING INC
SHADE AND SHIELD INC
SHADE SERVICES INC
SHAFFER'S IRRIGATION, INC.
SHAMBLIN CONSTRUCTION INC
SHAMROCK ROOFING CO, LLC
SHARK ELECTRIC INC
SHARK HEATING & COOLING LLC
SHARK HOME IMPROVEMENT LLC
SHARKEYS AIR INC
SHARP DEVELOPMENT OF SOUTHWEST FL INC
SHARP ELECTRIC INC
SHARP GENERAL CONTRACTORS INC
SHARP PERMIT SERVICES, INC
SHEA ROOFING LLC
SHEEGOG CONTRACTING
SHEENE CONSTRUCTION INC
SHEET MAGIC METAL INC DBA AKM ROOFING
SHELCIDY CUSTOM REMODELING
SHELL CREEK DEMOLITION CONTRS
SHENANDOAH GENERAL CONSTRUCTIONS LLC
SHERLOCK OHMS LLC
SHEWSKI ROOFING INC
SHINGLE MASTER ROOFING & CONST
SHIPPS EXCAVATING INC.
SHORE POWER ELECTRIC LLC
SHORELINE FOUNDATION INC
SHORELINE MARINE CONSTRUCTION
SHOWALTER CONSTRUCTION
SHUE-KAUFFMAN INCORPORATED
SHUMATE MECHANICAL ORLANDO INC
SHUTTERS 9-1-1 LLC
SHUTTERS239
SIBERIAN CONSTRUCTION INC
SIESTA KEY PLUMBING, LLC
SIESTA POOLS INC
SIESTA ROOFING LLC
SIGGS AIR CONDITIONING INC
SIGN & DESIGN USA, INC
SIGN ON, LLC
SIGN STOP PLUS
SIGN SYSTEMS & GRAPHIC DESIGNS
SIGN TECH INC
SIGNARAMA SARASOTA
SIGNATURE ELECTRIC INC
SIGNATURE KITCHEN & BATH REMODELING, INC
SIGNATURE PLUMBING INC
SIGNATURE PRIVACY WALLS OF FLORIDA INC
SIGNATURE ROOFING OF TAMPA BAY
SIGNATURE SECURITY & SOUND DESIG
SIGNCORP, INC.
SIGNCRAFTERS OF CENTRAL FL INC
SIGNET POOL
SIGNMASTERS OF FLORIDA
SIGNS & THINGS
SIGNS 2 GO INC
SIGNS CENTER
SIGNS IN ONE DAY
SIGNS-R-US LLC
SIGNSTAR
SILVERS SYSTEMS INC
SIMMTEGRITY AIR INC
SIMON ROOFING & SHEET METAL
SIMPLY SOLAR SERVICES INC
SIMPLY TREES, LLC
SIMPSON CONSTRUCTION AND ROOFING INC
SINCLAIR CONSTRUCTION
SIR SPEEDY
SITE WORX & SEPTIC INC
SIVCO LLC
SJM ELECTRIC CORP
SJMS INC
SKANSKA USA BUILDING INC
SKIP'S AIR CONDITIONING AND APPLIANCE SERVICE INC
SKY SOLAR ENERGY INC
SKYBILT, LLC
SKYETEC ENGINEERING SERVICES
SKYLINE BUILDERS GROUP INC
SKYLINE CONSTRUCTION SERVICES
SKYLINE DEVELOPMENT OF SW FL
SKYMARK ROOFING, LLC
SKYWAY CONSTRUCTION FL LLC
SKYWAY SPRINKLER LLC
SLACK CONSTRUCTION INC
SLAUBAUGH ALUMINUM & VINYL
SLAY'S RESTORATION LLC
SLENTZ ELECTRIC INC
SLOCUM PLATTS ARCHITECTS
SMART CHOICE ROOFING LLC
SMART PRO ELECTRIC LLC
SMARTWATCH SECURITY AND SOUND LLC
SMITH'S ELECTRIC INC
SMITHCO HOMES INC
SMITTYS AIR
SMITTYS AIR CONDITIONING INC
SMITTYS AIR INC
SMOTHERS BROTHERS AC INC
SNIDER ROOFING INC
SOBE BUILDERS LLC
SOFTRIM LLC
SOL ELECTRIC LLC
SOLAR ADVANTAGE LLC
SOLAR BEAR LLC
SOLAR DIRECT INC
SOLAR ENERGY SOLUTIONS OF AMERICA INC
SOLAR ENERGY SYSTEMS & SERVICE
SOLAR ENERGY WORLD LLC
SOLAR MAX INC
SOLAR ROOF SOLUTIONS INC.
SOLAR SHIELD INDUSTRIES INC
SOLAR SHIELD URETHANE ROOF SYS
SOLAR SHIELD WINDOWS & MORE
SOLAR SHIELD WINDOWS LLC
SOLAR SOURCE
SOLAR SPECIALIST INC
SOLAR SUN, LLC
SOLARPRO SOLUTIONS LLC
SOLARWISE ENERGY SOLUTIONS LLC
SOLID CONSTRUCTION OF FLORIDA INC
SOLIDCONST LLC
SOLIMINI ENTERPRISE INC
SOLLEVELD ENTERPRISES LLC
SOLO ELECTRIC INC
SOLTECH ELECTRIC
SOLTECH ENERGIES,LLC
SOLUTIONS INC
SOMESON HOMES INC
SOMICH CORP
SONITROL OF TALLAHASSEE INC
SONSHINE ROOFING INC
SOS AIR CONDITIONING & HEATING
SOS ROOFING INC
SOUND BUILDING CONTRACTORS
SOUTH CENTRAL ELECTRIC LLC
SOUTH EDGE CONSTRUCTION LLC
SOUTH FL PAINTING & WATERPROOF
SOUTH FLORIDA FIRE PROTECTION LLC
SOUTH FLORIDA PLUMBING
SOUTH POINTE BUILDING AND DEVELOPMENT LLC
SOUTHEAST ALUMINUM INC
SOUTHEAST IRRIGATION SOLUTIONS INC
SOUTHEAST MECHANICAL OF FLORID
SOUTHEAST ROOFING & CONSTRUCTION, INC.
SOUTHEAST ROOFING CONSULTANTS INC
SOUTHEAST SIGNS LLC
SOUTHEASTERN ENG & CONSTR INC
SOUTHEASTERN HOME IMPROVEMENTS, LLC
SOUTHEASTERN LIGHTING SOLUTIONS INC
SOUTHEASTERN PERMIT SERVICE LLC
SOUTHEASTERN ROOFING AND CONSTRUCTION LLC
SOUTHEASTERN SITE DEVELOPMENT
SOUTHEASTERN SURVEYING AND MAPPING CORPORATION
SOUTHEASTERN WIRING LLC
SOUTHERN ALUMINUM INC
SOUTHERN AQUATICS INC
SOUTHERN CROSS BLDG SOLUTIONS
SOUTHERN CROSS CONTRACTING SERVICES LLC
SOUTHERN CROSS CONTRACTING, INC.
SOUTHERN CROSS FIRE PROTECTION LLC
SOUTHERN CROSS STORM PROTECTION LLC
SOUTHERN CROWN HOMES INC
SOUTHERN ELECTRIC OF SWFL LLC
SOUTHERN ELECTRIC SERVICES LLC
SOUTHERN ENERGY ELECTRIC CO
SOUTHERN ENERGY SYSTEMS
SOUTHERN EQUIPMENT CORP
SOUTHERN GARAGE DOORS INC
SOUTHERN GULF CONSTRUCTION INC
SOUTHERN HOME TECHNOLOGY INC
SOUTHERN INDUSTRIAL ELECTRIC
SOUTHERN LIGHT LLC
SOUTHERN LIGHTS ELECTRICAL
SOUTHERN MOST POOLS INC
SOUTHERN PRO RESTORATION LLC
SOUTHERN ROOFING AND RENOVATIONS ORLANDO
SOUTHERN SAFE CONSTRUCTION LLC
SOUTHERN SERVICES SWFL LLC
SOUTHERN SHORES CONSTRUCTION INC
SOUTHERN SIDING
SOUTHERN SPRINKLER & IRR OF NP
SOUTHERN STATE ELECTRICAL CONTRACTOR
SOUTHERN STUCCO & STONE INC
SOUTHERN VALUES COOLING & HEAT
SOUTHLAND CONSTR SERVICES INC
SOUTHLAND CONTRACTORS INC
SOUTHLAND PROCESS GROUP LLC
SOUTHLAND RESTAURANT SERVICES
SOUTHPORT CONSTRUCTION CORP
SOUTHSHORE ROOFING AND EXTERIORS
SOUTHWEST BUILDING INC
SOUTHWEST COMMUNICATION SOLUTIONS INC
SOUTHWEST CONCRETE & MASONRY SYSTEMS LLC
SOUTHWEST CONSTRUCTION SERVICES INC
SOUTHWEST ELECTRICAL ASSOCIATES LLC
SOUTHWEST ELECTRICAL CONTRACTING SERVICES LTD
SOUTHWEST FL ORIG CARLSON ROOF
SOUTHWEST FLA WATER & MOLD
SOUTHWEST FLORIDA AIR & REFRIGERATION
SOUTHWEST FLORIDA ALARM & SEC
SOUTHWEST GAS LLC
SOUTHWEST HEATING AND COOLING
SOUTHWEST INNOVATIONS CONSTR
SOUTHWEST PLUMBING SERVICES INC
SOUTHWEST POOLS BUILDERS & SVC
SOUTHWEST POOLS BUILDERS AND SERVICE
SOUTHWEST PROP MGMT & ALUM SVC
SOUTHWEST VENTILATION
SOUTHWEST WALL TECHNICIANS LLC
SOUVENIR BUILDERS INC
SOVANIC INC
SPACE COAST FIRE & SAFETY (PG)
SPACE COAST FIRE & SAFETY INC
SPANGLER ROOFING LLC
SPANNINGER PLUMBING INC
SPARKLING KLEEN POOLS & SPAS
SPARKY ELECTRIC
SPARTAN AIR SOLUTIONS, LLC
SPARTAN CONTRACTING CORP
SPARTAN PLUMBING, LLC
SPECIAL GRAPHICS & MAINTENANCE INC
SPECIALE CONSTRUCTION SERVICES LLC
SPECIALIZED PIPE TECHNOLOGIES
SPECIALIZED PROPERTY RESTORATION LLC
SPECIALTY AIR CONDITIONING, LLC
SPECIALTY AIR INC
SPECIALTY ROOFING INC
Specified Architectural Systems, Inc.
SPECTRUM CONTRACTING INC
SPECTRUM GAS SOLUTIONS LLC
SPECTRUM MECHANICAL
SPECTRUM UNDERGROUND, INC.
SPECTRUM VOICE & DATA INC
SPEED DRY, INC
SPEEDWAY ELEC OF WINTER HAVEN
SPIRIT POOLS INC
SPLASH POOLS
SPLIT ROCK ASSOCIATES INC
SPOT ON ELECTRIC, LLC
SPRINGER-PETERSON ROOFING & SHEET METAL INC
SPRINKLERMATE FIRE PROTECTION SYSTEMS INC
SPRINKLERMATIC FIRE PROTECTION SYSTEMS INC
SPRINKLERMATIC FLORIDA LLC
SPRINKLERWORKS
SQUARE ONE CONTRACTING INC
SQUARE ONE ROOFING LLC
SQUARE POINT SYSTEMS LLP
SRC SERVICES INC
SRQ AC LLC
SRQ AIR, LLC
SRQ BUILDING GROUP LLC
SRQ BUILDING SERVICES INC
SRQ COASTAL CONSTRUCTION COMPANY
SRQ CONTRACTING LLC
SRQ ELECTRIC INC
SRQ HEATING AND COOLING INC
SRQ PA OFFICE
SRQ PLUMBING LLC
SRQ ROOFING COMPANY
SRQ STORM PROTECTION LLC
SSI MECHANICAL
STALEY INC
STALLER PLUMBING
STANDARD PLUMBING CORP
STANEK VINYL WINDOWS FL CORP
STANFORD GROUP LLC
STANLEY ACCESS TECHNOLOGIES
STANLY SWIDERSKI PLUMBING LLC
STANSELL PROPERTIES & DEVELOPMENT LLC
STANTEC CONSULTING SERVICES INC
STAR ELECTRIC SERVICES INC
STAR FIRE PROTECTION
STARGARDT & ASSOCIATES LLC
STARK'S CONCRETE
STARLING ELECTRIC INC
STARLITE CONSTRUCTION CORP
STARR PROTECTION SERVICES INC
STARS & STRIPES PLUMBING, LLC
STARTER HOME CONSTRUCTION LLC
STATE & COUNTY CONSTRUCTION
STATE A/C & HEATING INC
STATE ENERGY CONSERVATION
STATE FIRE PROTECTION INC
STATELINE CONTRACTORS INC
STATEWIDE ENGERY CORP
STATEWIDE RESTORATION SERVICES
STATEWIDE ROOFING/SHEETMETAL INC
STATEWIDE SHUTTERS INC
STATEWIDE SPECIALTIES INSTALL
STATEWIDE WINDOWS & DOORS, INC.
STAY DRY ROOFING LLC
STEADFAST ROOFING
STEC
STEEL PANEL CONSTRUCTION LLC
STEEL PLUMBING INC
STELLAR DEVELOPMENT
STELLAR ROOFERS AND CONSTRUCTION LLC
STELMOK CONSTRUCTION LLC
STEPHEN CARLSON ROOFING INC
STEPHEN E DAVIS
STEPHEN'S ELECTRIC LLC
STERLING MANUFACTURING
STERLING QUALITY ROOFING INC
STEVAR PROPERTY DEVELOPMENT
STEVE J DAVIS GENERAL CONTRACTOR LLC
STEVE KRING CONSTRUCTION CO
STEVE PARISIAN CONSTRUCTION CO
STEVE SENN ELECTRIC INC
STEVE SOLOMON CONSTRUCTION AND DEVELOPMENT INC
STEVE TROESCH PLUMBING
STEVE'S ROOFING & REPAIRS LLC
STEVE'S ROOFING SERVICES INC- INACTIVE
STEVE'S TREE & HAULING SERVICE LLC
STEVEN BRAMLEY CONSTRUCTION
STEVEN MERCER (OWNER BUILDER)
STEVENS CONSTRUCTION INC
STEWART & SONS ELECTRIC LLC
STEWART TENNIS COURTS & FENCE
STILLWATERS ELECTRIC INC
STIRLING & WILBUR ENGINEERING GROUP
STOCKBARGER GLASS INC
STOLTZFUS REMODELING LLC
STONE AGE PAVERS INC
STONE PLUMBING & MECH PIPING
STONEHAVEN BUILDERS INC
STONY ELECTRICAL CONTRACTOR LLC
STORM GUARD ROOFING AND RESTORATION, LLC
STORM MARINE
STORM PROTECTION INC
STORM ROOFING & REPAIR LLC
STORM SAFE
STORM SHIELD WINDOWS & DOORS
STORM SMART BUILDING SYSTEMS INC
STORM SOLUTIONS INC
STORM TIGHT WINDOWS SWF LLC
STORMFITTERS CORP
STOUT HOMES INC
STRADA SERVICES, LLC
STRAGE ELECTRIC LLC
STRAIGHT FORWARD CONSTRUCTION LLC
STRAIGHT LINE ALUM CONSTR 1
STRAIGHT LINE ALUMINUM CONSTRUCTION LLC
STRAIGHT LINE CONSTRUCTION OF GAINESVILLE LLC
STRATICON LLC
STREAMLINE HEATING & AIR LLC
STREAMLINE PLUMBING INC
STRESS FREE CONSTRUCTION, LLC
STRODE PLUMBING INC
STRONG ROOFING GROUP LLC
STRONGHOLD ROOFING & SOLAR
STRONGHOLD ROOFING & SOLAR
STROOP DESIGN & CONSTRUCTION INC
STRUCTURAL PRESERVATION SYSTEM
STRUCTURE SOLUTIONS
STRUCTURES DEVELOPMENT GROUP INC
STRUXURE OUTDOOR NAPLES
STRYKER ELECTRIC & AIR
STRYKER ELECTRICAL CONTRACTING INC
STUART BROWN INC
STUART DIENES CONSTRUCTION GRP
STUART HOME SERVICES LLC
STURGILL HOMES, INC
STUTZMAN ELECTRICAL SERVICES LLC
STUTZMAN HOMES AND DESIGN
STYLE CREST INC
SUAREZ PLUMBING CO INC
SUBURBAN PROPANE
SULLY'S LLC
SUMMER KOOL HEATING & AIR LLC
SUMMERS FIRE SPRINKLERS INC
SUMMIT BUILDING CONTRACTORS INC
SUMMIT CONTRACTING GROUP, INC.
SUMMIT FIRE & SECURITY LLC
SUMMIT ROOFING & SOLAR, LLC
SUMPTER ELECTRIC INC
SUN AND STORM SYSTEMS LLC
SUN BAY CONSTRUCTION CO INC
SUN COAST ROOFING SERVICES INC
SUN COOL AIR LLC
SUN ELECTRIC SERVICE INC
SUN ELECTRIC WORKS LLC
SUN KISSED CONSTRUCTION INC
SUN PROTECTION OF FLORIDA LLC
SUN QUEST HOMES INC
SUN STATE LANDSCAPE MANAGEMENT
SUN STATE ROOFING & REPAIR
SUNBELT ELECTRIC INC
SUNBELT HOME SOLUTIONS INC
SUNCASTLE ROOFING INC
SUNCITY RESCREENING & HOME IMPROVEMENT LLC
SUNCOAST BUSINESS TECHNOLOGIES
SUNCOAST COMFORT HEATING & COOLING LLC
SUNCOAST COMMERCIAL GLASS & WINDOW INC
SUNCOAST DEVELOPMENT SERVICES
SUNCOAST DOCK AND BOATLIFT LLC
SUNCOAST ELECTRIC OF MANATEE INC
SUNCOAST ELECTRICAL SERVICES LLC
SUNCOAST FIRE AND SAFETY EQUIP
SUNCOAST GENERAL BUILDERS INC
SUNCOAST PLUMBING & ELECTRIC
SUNCOAST PLUMBING LLC
SUNCOAST PLUMBING SERVICE LLC
SUNCOAST POOL KING LLC
SUNCOAST POWER SOLUTIONS CORPORATION
SUNCOAST REMODELING INC
SUNCOAST ROOFERS LLC
SUNCOAST ROOFS, INC.
SUNCOAST SIGN SHOP INC
SUNCOAST WRECKING AND ASSET RECOVERY
SUNERGY ROOFING & CONSTRUCTION INC
SUNERGY SOLAR LLC
SUNFLO ROOFING
SUNLIGHT SOLAR
SUNLIGHT SOLAR
SUNMASTER OF NAPLES, INC.
SUNNY COAST BUILDERS INC
SUNNY STATE ROOFING INC
SUNPEAK LLC
SUNRIFT ELECTRIC LLC
SUNRISE ENTERPRISES AKD INC
SUNRISE IRRIGATION
SUNRISE PROJECTS LLC
SUNRUN INSTALLATION SERVICES INC
SUNSEEKER POOL & SPA LLC
SUNSET AIR & HOME SERVICES INC
SUNSET BAY BUILDERS INC
SUNSET COAST PLUMBING INC
SUNSET POOLS INC
SUNSET ROOFING
SUNSHINE AIR OF CHARLOTTE COUNTY INC
SUNSHINE ELECTRIC OF PINELLAS
SUNSHINE ELECTRICAL CONTRACTORS CORP.
SUNSHINE ELECTRICAL SERVICES, INC
SUNSHINE HOMES OF FLORIDA, LLC
SUNSHINE NEW HOME CONSTRUCTION LLC
SUNSHINE STATE ELECTRIC INC
SUNSHINE STATE HURRICANE PROT
SUNSHINE STATE PLUMBING
SUNSTATE CONTRACTING LLC
SUNSTATE DOOR & GATE INC
SUNSTATE HOME BUILDER LLC
SUNSTATE MECHANICAL CONTRACTORS INC
SUNSTATE PAVERS INC
SUNTAN POOLS, LLC
SUNTECH ELECTRICAL CONTRACTORS
SUNVENA SOLAR LLC
SUNWORKS ELECTRIC LLC
SUPER HEAT AND AIR
SUPER SHARK POOLS LLC
SUPERB ALUMINUM & SCREENING
SUPERIOR A/C (ROBBIE)
SUPERIOR ARCHITECTURAL SOLUTIONS, INC.
SUPERIOR COMMERCIAL SERVICES
SUPERIOR COMMUNICATIONS & SEC
SUPERIOR CONCRETE CONST
SUPERIOR CONTRACTING & ENVIRON
SUPERIOR ELECTRICAL CONSULTANTS LLC
SUPERIOR ELECTRICAL SERVICES
SUPERIOR FIRE ALARM & COMMUNICATIONS LLC
SUPERIOR HEATING & COOLING
SUPERIOR HEATING-COOLING CORP
SUPERIOR HOME ENERGY IMPROVEMENT SERVICES INC
SUPERIOR INC
SUPERIOR POOL CARE
SUPERIOR POOLS OF SW FL INC
SUPERIOR PROPANE
SUPERIOR PROPERTY SOLUTIONS, LLC
SUPERIOR ROOFING INC
SUPERIOR ROOFING UNLIMITED LLC
SUPREME ELECTRICAL CONTRACT
SUPREME PROPERTY SOLUTIONS LLC
SUPREME SERVICE AIR CONDITIONING AND HEATING INC
SURE TEMP COOLING AND HEAT INC
SURE TEMP MANUFACTURING CO
SURETY CONSTRUCTION COMPANY
SURFACE MD INC
SURFSIDE PLUMBING INC
SURGAT ENTERPRISE LLC
SUTHERLAND BUILDING SERVICES INC
SUTTER ROOFING COMPANY OF FLORIDA
SUTTON CONTRACTING INC.
SW FLORIDA FIRE PROTECTION INC
SW PLUMBING HEATING & COOLING
SWAILES FUNROOM SUNROOM INC
SWAN ELECTRIC INC
SWANSON FIRE PROTECTION
SWARTZ COOLING & HEATING INC
SWFL A/C SERVICES, LLC
SWFL PREMIER CONSTRUCTION, CORP
SWIFT PLUMBERS
SWIFT ROOFING SERVICES INC
SWIM INC
SWITCH OVER ELECTRIC CO
SWORDSMEN ROOFING & CONSTRUCTION LLC
SYLVANIA LIGHTING SERVICES
SYMBIONT SERVICE CORP
SYMONS CONSTRUCTION LLC
SYNERGY BUILDING CORP
SYNERGY CONSTRUCTION SW FL LLC
SYNERGY ELECTRIC & LIGHTING
SYNERGY LIGHTING INC
SYNERGY NDS, INC
SYSTEM BUILT PROPERTIES GROUP LLC
SYSTEM BUILT PROPERTIES, LLC
SYSTEM TECH SERVICES INC
T
T AND T ROOFING INC
T BALDWIN ENVIRONMENTAL SERV
T MCTIGUE CONSTRUCTION INC
T ROBERTS & SONS INC
T&B REMODELING INC
T&H SERVICES INC
T&J SWIMMING POOLS, INC.
T&M ALUMINUM
T&M CONSTRUCTION INC
T&T FIRE ALARM AND ELECTRICAL, LLC
T-TOP ELECTRIC LLC
T.E.C.C. SERVICES LLC
T3 PLUMBING INC
TACTICAL ROOFING SOLUTIONS LLC
TADLOCK ROOFING INC
TAILORED BUILDERS LLC
TAILORED INTERIORS LLC
TAK CONSTRUCTION CORP
TALLENT ROOFING INC
TAMARA HOMES INC
TAMPA BAY BUILDING AND REMODELING LLC
TAMPA BAY MARINE INC
TAMPA BAY ROOFING SERVICES
TAMPA BAY SOLAR
TAMPA BAY TRANE
TAMPA HONEST ABE ROOFING
TAMPA SCREENS & ALUMINUM INC.
TANDEM CONSTRUCTION
TANDEM ELECTRIC LLC
TANGO DEVELOPMENT INC
TANKTEK INC
TANNER FIRE AND SAFETY EQUIPMENT INC
TAPPOUNI MECHANICAL SERVICES
TARGET ROOFING AND SHEET METAL
TARHEEL ROOFING INC
TARPON BAY ELECTRIC LLC
TARPON BAY GENERAL CONTRACTING
TARPON COAST CONSTRUCTION MGMT
TARPON COAST PLUMBING LLC
TAYLOR CONSTRUCTION GROUP LLC
TAYLOR PLASTERING INC
TB LANDMARK CONSTRUCTION INC
TDS CONSTRUCTION INC
TEAM CLARK, INCORPORATED
TEAMRUSH INC
TECH ELECTRIC LLC
TECHNICAL ELECTRIC SYSTEMS INC
TECHNICAL ELECTRICAL INC
TECHNICAL MGMT ASSOCIATES INC
TECHNICAL POWER SYSTEMS INC
TECHNICAL SERVICES
TECHNICAL TREATMENT SERVICES
TECO PEOPLES GAS
TEDCO CORP
TEDDYS HANDYMAN & REMODELING INC
TEI ELECTRICAL CONTRATORS INC
TEIXEIRA CONSTRUCTION INC
TEK9 MOBILE HOME INSTALL LLC
TEKRAM ROOFING & CONSTRUCTION
TELECTRIC COMMUNICATION SVCS
TELEMETRY SYSTEMS INC
TELETECHSERV GA LLC
TEMPERATURE SERVICES INC
TEN TALENTS MANAGEMENT LLC
TENBUSCH CONSTRUCTION, INC
TENNX LLC
TENT
TEP DESIGN BUILD, INC
TERRASOUTH ENVIRONMENTAL LLC
TERRELL ELECTRIC INC
TERRY PAINTER MOBILE HOME SET UP
TERRY REAM CONSTRUCTION INC
TERRY'S PLUMBING & AIR INC
TERRY'S PLUMBING AIR AND ENERGY INC
TERRY'S PLUMBING SERVICE INC
TERRYS PLUMBING SERVICE INC
TESAR HOMES INC
TESLA ENERGY OPERATIONS
TEST_COV
THAXTON ENTERPRISES INC
THE A/C DUCTOLOGIST, LLC
THE AFFORDABLE GROUP INC
THE ANGEL COOLING LLC
THE AWNING FACTORY
THE BEST OF SW FRAMING INC
THE BMC GROUP
THE BUILDING COMPANY
THE CABINET GUY OF ENGLEWOOD INC
THE CGC GROUP FLORIDA LLC
THE CHARLES & CHASE GROUP INC
THE COASTAL ROOFING
THE CONCRETE GUY LLC
THE CONSTRUCTION EXPERT OF FLORIDA LLC
THE COOL-IT MAN INC
THE COOLING COMPANY OF SW FL
THE DAMEX CORPORATION
THE DAN WRIGHT CORP
THE DAVIN GROUP INC
THE DECK DOCKTORS INC
THE DOORS SPECIALIST CORP
THE DRAGE CORPORATION
THE DRAIN PROS
THE DRAIN TEAM
THE ECOPLUMBERS OF FLORIDA LLC
THE ELECTRIC CONNECTION INC
THE FAMILY CRAFTSMAN
THE FRIENDLY PLUMBER
THE GALLINA COMPANIES
THE GARRY GROUP
THE GAS COMPANY, LLC
THE GAS WORKS OF TAMPA BAY INC
THE GENERAL CONTRACTOR
THE HANDYMAN COMPANY
THE HASKELL COMPANY
THE HEIGHTS ALUMINUM INC
THE HOME DEPOT
THE HOME DEPOT (BOLING)
THE HOME DEPOT (DAULT)
THE HOME DEPOT (FRANCIS)
THE HOME DEPOT (GUILLORY)
THE HOME DEPOT (HOLEVA)
THE HOME DEPOT (LIPMAN)
THE HOME DEPOT (MAHAN)
THE HOME DEPOT (OLMSTEAD)
THE HOME DEPOT (PERKEY)
THE HOME DEPOT (RAMDIAL)
THE HOME DEPOT (ROBERTS)
THE HOME DEPOT (SWANNER)
THE HOME DEPOT INSTALLED SALES
THE HOME PEOPLE
THE ISLAND BUILDING COMPANY
THE LABRAKE COMPANY LLC
THE ORIGINAL ELECTRICIAN LLC
THE OSCAR W . LARSON COMPANY
THE PEOPLES PLUMBER
THE PHM GROUP INC
THE PLANTATION COMPANY OF SARASOTA INC
THE PLATINUM GROUP INC
THE PLUMBER LLC
THE PLUMBING CONNECTION
THE PLUMBING PRO INC
THE PROS LLC
THE ROOF DEPOT INC
THE STANDPOINT GROUP LLC
THE SURFIN' PLUMBERS HEATING AND COOLING
THE TITANIUM PLUMBER LLC
THE TRIAD GROUP INC
THE UNSTOPPERS INC
THE WATER HEATER CONNECTION
THE WATER WORKS
THE WATTS GROUP, LLC
THE WHOLE NINE YARDS INC
THE WINDOW DEPOT LLC
THERMOTANE PROPANE
THIRD COAST PLUMBING & GAS
THIRD GENERATION PLUMB & MECH
THIS IS YOUR PLUMBER
THIS THAT SERVICE LLC
THOMAS A NORVILLE (OWNER BUILDER)
THOMAS BLANTON PLUMBING INC
THOMAS BUILDING & REMODELING INC
THOMAS CONSTRUCTION AND CONSULTING SERVICES LLC
THOMAS DOLLE CABINETRY
THOMAS FRANCIS NIKLA
THOMAS H WILLIFORD ARCHITECT PA
THOMAS LEE WHITE III
THOMAS LIFSEY JR BUILDER INC
THOMAS RONDE ROOFING LLC
THOMAS S GORSKI AIR COND
THOMAS S GORSKI AIR CONDITIONING INC
THOMAS SIGN & AWNING CO INC
THOMPKINS CONTRACTING INC
THOMPSON ALUMINUM INC
THOMPSON THRIFT CONSTRUCTION INC
THOMPSON'S AIR CONDITIONING OF SWF, INC
THOMPSONS AIR CONDITIONING OF SWF INC
THORNBERRY CUSTOM BUILDERS INC
THREE D ENTERPRISES INC
THREE SEVEN DEVELOPMENT AND CONSTRUCTION, LLC
THROWER CONCRETE INC
THS NATIONAL, LLC.
THUNDERBOLT ELECTRIC
TIDWELL ELECTRIC COMPANY INC
TIER 1 ROOFING
TIES 360 LLC
TIM ROANE PE DMK ASSOCIATES INC
TIMELESS CONSTRUCTION LLC
TIMONEY ELECTRIC INC
TIMOTHY E. KESSLER DBA TEK 9 MOBILE HOME INSTALL, LLC
TIOLI ROOFING
TITAN CONTRACTING, LLC
TITAN CONTRACTOR SERVICES LLC
TITAN ELECTRIC & AIR INC
TITAN FIRE PROTECTION, INC.
TITAN PLUMBING & ELECTRIC
TITAN SOLAR POWER FL INC
TITANIUM FLORIDA LLC
TITANZ PLUMBING INC
TK ELECTRIC INC
TK ELECTRIC INC
TK ELEVATOR
TKO MECHANICAL INC
TLC DIVERSIFIED INC
TLP ELECTRIC SERVICE
TMC GENERAL CONTRACTOR LLC
TNT ELECTRIC CONTRACTORS INC
TNT ENVIRONMENTAL LLC
TNT METAL BUILDERS INC
TNT PLUMBING LLC
TO DO LLC
TOBY LEE TOKES
TOCAR DRYWALL OF CHARLOTTE CTY
TODA CONTRACTING GROUP, LLC
TODD A NOWE
TODD D. CHAPMAN (OWNER BUILDER)
TODD EMMONS INC
TODD ONKEN CONSTRUCTION GROUP
TOLL BROS INC
TOM BARRIERE PLUMBING INC
TOM JOYCE ROOFING INC
TOM KANE CONSTRUCTION INC
TOM WESSEL CONSTRUCTION CORP
TOMAZ CONTRACTING INC
TOMMY'S AIR
TOMMY'S AIR CONDITIONING INC
TONY BEAL ROOFING
TONY GMEINDER INC
TONY THE PLUMBER INC
TONY'S SHUTTERS SCREENS & WINDOWS INC
TOP LINE ROOFING INC
TOP NOTCH BUILDERS LLC
TOP NOTCH ROOFING CONTRACTOR
TOP NOTCH ROOFING INC
TOP NOTCH WINDOW & DOOR LLC
TOP QUALITY REMODELING INC
TOP2 AIR LLC
TOPNOTCH REMODELERS LLC
TORNADO CONSTRUCTION OF FLORIDA LLC
TOROCCO'S COOLING & HEATING INC
TORRES ELECTRIC LLC
TORTUGA POOLS AND SPAS
TOTAL AIR SOLUTIONS LLC
TOTAL BUILDING SOLUTIONS INC
TOTAL COMFORT COOLING & HEATING INC
TOTAL COMFORT WINDOW AND SCREENING INC
TOTAL ELECTRIC CONTRACTING LLC
TOTAL HOME BY JEAN PIERRE LLC
TOTAL HOME CARE HANDYMAN SERVICE, INC
TOTAL HOME ROOFING
TOTAL LIGHTING INSTALLATIONS
TOTAL REMODELING SOLUTIONS
TOTAL ROOFING CONTRACTORS INC
TOTAL SHUTTER TECHNOLOGIES INC.
TOTALLY COOL LLC
TOUGH CONSTRUCTION INC
TOWERQUEST
TOWNS ELECTRIC INC
TP THREE, LLC
TPI ALUMINUM SPECIALTIES INC
TPT CONSTRUCTION INC
TR LAYTON LLC
TR ZUKNICK INC
TRAC ENVIRONMENTAL SERVICES
TRACE ELECTRIC INC
TRACER ROOFING LLC
TRADEMARK ALUMINUM
TRADEMARK DOCK BOATLIFT & SEA
TRADEMARK ROOFING LLC
TRADEMARK SIGNS LLC
TRADEWIND DOORS LLC
TRADITION CENTRAL AIR INC
TRAKIT CONSTRUCTION
TRANSFORM ELECTRIC LLC
TRANSFORMERS BUILDING & REMODELING LLC
TREASURE COAST CUSTOM HOMES LLC
TREBOR INVESTMENT CORPORATION
TREE DRAGONS INC
TREEHOUSE CONSTRUCTION INC
TREND BUILDING AND DEVELOPMENT
TRENT CAMP (OWNER BUILDER)
TRI AREA ELECTRIC CONSTRUCTION
TRI COUNTY AIR CONDITIONING AND HEATING INC
TRI COUNTY AIR CONDITIONING-HEATING INC
TRI COUNTY LP GAS SERVICES INC
TRI TECH CONSTRUCTION & DESIGN
TRI TECH CONSTRUCTION & DESIGN
TRI-CARE SERVICES INC
TRI-CITY ELECTRICAL CONTRACTORS INC
TRI-COUNTY CUSTOM BUILDERS INC
TRI-COUNTY ELECTRIC INC
TRI-R MECHANICAL LLC
TRI-STATE SPRINKLER INC
TRIAD BUILDING PRODUCTS INC
TRIAD MECHANICAL OF PALM COAST LLC DBA TPC MECHANICAL
TRIAD SECURITY GROUP INC
TRICOUNTY LAND DEVELOPMENT, INC.
TRIDENT AIR CONDITIONING AND HEATING LLC
TRIDENT BUILDING SYSTEMS INC
TRIDENT CONSTRUCTION SERVICES, LLC
TRIMCRAFT OF FT MYERS INC
TRINITY BUILDERS OF SOUTHWEST FLORIDA, LLC
TRINITY CONSTRUCTION & DESIGN
TRINITY CONTRACTING & REMODELING LLC
TRINITY PROJECT MGMT GROUP INC
TRINITY SOLAR LLC
TRIPLE AAA CONSTRUCTION CORP
TRITON AIR AND HEAT INC
TRITON DOCK & PIER LLC
TRIUMPH AIR SOLUTIONS LLC
TRIUMPH ROOFING CORP
TROPIC GUARD INDUSTRIES LLC
TROPIC RENOVATIONS
TROPIC STORM PROTECTION INC
TROPIC-AIR CONDITIONING INC
TROPICAL BUILDERS INC
TROPICAL COMFORT AC INC
TROPICAL FENCE COMPANY
TROPICAL IRRIGATION MAINTENANCE, INC.
TROPICAL LANDSCAPE SOLUTIONS INC
TROPICAL POOLS & SPAS
TROPICAL POOLS & SPAS OF SW FL
TROPICAL POOLS FL LLC
TROPICAL ROOFING
TROPICAL ROOFING ENTERPRISES
TROPICAL SHORES BUILDING GROUP LLC
TROPICAL STORM SHIELD INC
TROPICGUARD CORPORATION
TROPICOOL AIR CONDITIONING INC
TROYER COMMERCIAL ROOFING LLC
TRS ROOFING INC
TRU-TEMP HEATING & COOLING INC
TRUE FENCE LLC
TRUE FLORIDA CONSTRUCTION LLC
TRUE NORTH ELECTRICAL, CORP.
TRUE NORTH RESTORATION OF SW FLORIDA
TRUE PLUMBING SERVICE INC
TRUE VISION REMODELING
TRUEX PREFERRED CONSTRUCTION
TRUST ROOFING
TRUSTED POOL AND SPA LLC
TS INTERNATIONAL PLUMBING LLC
TSP ELECTRIC
TUBULAR BUILDING SYSTEMS LLC
TUBULAR SKYLIGHT INC
TUCKER ELEC OF WINTER HAVEN
TUCKER HOME SERVICES INC
TUDI MECHANICAL SYSTEMS
TUFF MUDDERS
TUFF SHED INC
TURNER GRADING & EXCAVATING
TURNER ROSS CONSTRUCTION
TURNKEY ROOFING OF FLORIDA, INC.
TWC SERVICES INC
TWC SERVICES INC/ SCOTT
TWIN SERVICES HEATING AND COOLING INC.
TWO T'S SERVICES INC
TWYN ELECTRIC LLC
TY CLARK PLUMBING INC
TYCO INTEGRATED SECURITY LLC
TYLER EATON (OWNER BUILDER)
U.S. SHINGLE, LLC
UCI CONSTRUCTION SERVICES LLC
UCI2 CONSTRUCTION SERVICES, LLC
ULM BROTHERS INC
ULTIMATE AIR CONDITIONING INC
ULTIMATE AIR INC
ULTIMATE SERVICES AND MAINTENANCE L.L.C.
ULTIMATE UPGRADES INC
ULTRALUMINUM INC
ULTRATEK ASIA INC
ULTRATEK WORLDWIDE
UNDERHILL PLUMBING INC
UNICITY SOLAR, LLC
UNION CAPITAL ROOFING LLC
UNION PLUMBING INC
UNIQUE SECURITY INC
UNIQUE SERVICES
UNITED CONSTRUCTION GROUP
UNITED ELECTRIC
UNITED ELECTRIC CONTRACTORS, INC.
UNITED FIRE PROTECTION
UNITED GARAGE DOOR SVCS INC
UNITED GAS SERVICES INC
UNITED MECHANICAL LLC
UNITED RESTORATION SERVICES LLC
UNITED SHEET METAL & AIR COND
UNITED STATES AWNING COMPANY
UNIVERSAL AIR CONDITIONING CORP
UNIVERSAL AIR INC
UNIVERSAL CONTRACTING & SOLAR
UNIVERSAL ENGINEERING SCIENCES
UNIVERSAL FIRE SYSTEMS INC
UNIVERSAL ROOF & CONTRACTING
UNIVERSAL STRUCTURES INC
UNIVERSAL WINDOW SOLUTIONS LLC
UNLICENSED ACTIVITY - BURDI
UNLICENSED ACTIVITY - KLEES
UNLICENSED ACTIVITY - LEBEDUN
UNLIMITED CONSTRUCTION & MASONRY SERVICES LLC
UNLIMITED CONSTRUCTION AND MASONRY SERVICES, LLC.
UNLIMITED FILL INC
UNLIMITED SOLAR TECHNOLOGY
UNLIMITED WATERS INC
URBAN PLUMBING SERVICE INC
URBAN SOLAR GROUP
URETHANE SYSTEMS INC
US AIR HEATING AND AIR CONDITIONING SERVICES P LLC
US AIR SERVICES INC
US ROOFING GROUP LLC
US SIGN & MILL CORP
US SOLAR SQUARED, LLC / US SOLAR
US WATER SERVICES CORPORATION
USA CONSTRUCTION & PAINTING
USA CONSTRUCTION INC
USA FENCE COMPANY
UTILITY SALES & SERVICE INC
V-CO SYSTEMS INC
V.K. CONSTRUCTION LLC
VACS RESTORATIONS INC.
VALCO ENTERPRISES
VALCOURT EXTERIOR BUILDING SERVICES OF FLORIDA LC
VALOR CONTRACTING SERVICES LLC
VAN CON INC
VANGUARD HAMMER PROPERTY RENO
VANS HEATING & COOLING INC
VANTAGE CONSTRUCTION SERVICES,LLC
VARA ELECTRIC CORP
VARGAS ELECTRIC SERVICE INC
VARIETY FENCE LLC
VAUPEL ELECTRIC LLC
VEIGEL CARPENTRY INC
VELOCITY AIR CONDITIONING INC
VENETIAN HOMES INC
VENETIAN POOLS INC
VENICE BUILDERS LLC
VENICE CONSTRUCTION CLEAN UP
VENICE CONSTRUCTION SERVICES
VENICE COOLING AND HEATING INC
VENICE COOLING, HEATING, & PLUMBING, LLC
VENICE ELECTRIC INC
VENICE HG LC
VENICE LAND CLEARING INC
VENICE POLICE DEPARTMENT - MARINE PATROL
VENICE WINDOW & DOOR INC
VENTURE BUILDERS INC
VENTURE CONSTRUCTION COMPANY
VERACON LLC
VERGONA BOWERSOX ELECTRIC INC
VERICON CONSTRUCTION COMPANY, LLC
VERN BORNTREGER LLC
VERSTAR CONSTRUCTION SERVICES, LLC
VET CONSTRUCTION INC
VET'S ROOFING, INC.
VETERAN AIR CONDITIONING
VETERAN BUILDERS OF VENICE
VETERAN COOLING LLC
VETERAN PLUMBING LLC
VETERAN ROOFING INC
VETERANS GARAGE DOOR LLC
VETERANS ROOFING, LLC
VICTOR BARRETO ELECTRIC LLC
VIEW MECHANICAL
VIKING BUILDERS OF SW FLORIDA LLC
VIKING CONST CORP OF SW FL
VILLA ENTERPRISES, INC.
VILLAGE POOLS OF CENTRAL FL, LLC
VINCE TISCIO AIR
VINCENT TISCIO INC
VINTAGE POOLS OF SWFL LLC
VINYLTECH LLC
VIRTUS GROUP LLC
VISION CONTRACTORS
VISION DEVELOPMENT & CONSTRUCTION
VISION ELECTRIC SRQ LLC
VISION SOLAR FL LLC
VITEX SYSTEMS INC
VIVINT INC
VIVINT SOLAR DEVELOPER LLC
VOELLER CONSTRUCTION INC
VOGEL CONSTRUCTION INC
VOGEL ROOFING LLC
VOGT ELECTRIC LLC
VOLK ELECTRIC INC
VOLT ELECTRICAL SERVICES
VOLTS EDGE ELECTRIC LLC
VOLTS ELECTRICAL SERVICES LLC
VOMHAGEN HOMES LLC
VQUEST LLC
VSC FIRE & SECURITY INC
VT PLUMBING AND DRAIN LLC
VULCAN INDUSTRIES INC
W BARNETT ENTERPRISES INC
W.W. GAY MECHANICAL CONTRACTOR OF ORLANDO INC
WADE BUILDING CONTRACTORS INC
WADE'S HEATING & COOLING LLC
WADEVCO
WAGLER PLUMBING INC
WAGLER REMODELING COMPANY INC
WAHOO ELECTRIC, LLC
WAL-MARK CONTRACTING GROUP LLC
WALFORD CONSTRUCTION INC
WALKER CANVAS AWNINGS INC
WALKER ELECTRIC
WALLER CONSTRUCTION INC
WALRUS CONSTRUCTION
WALSH COOLING & HEATING LLC
WALSH ROOFING SERVICES OF TAMPA BAY, LLC
WALTBILLIG & HOOD GENERAL CONTRACTORS LLC
WALTER JAMES & SON PLUMBING
WALTON INC
WALTON TRACTOR & PLUMBING SERV
WARBINGTON CONSTRUCTION, LLC
WARD'S ALUMINUM & RESCREEN
WARFIELD PLUMBING INC
WARREN CRAIG HUARTSON (OWNER BUILDER)
WARREN HOPE BUILDERS INC
WARREN ZIEMKE DRYWALL INC
WASHINGTON ELECTRICAL SERVICE
WASHINGTON QUALITY CONSTRUCTION INC..
WATCO CONSTRUCTION INC
WATER DESIGNS OF SARASOTA INC
WATER SAFE PLUMBING
WATERFORD CONSTRUCTION INC
WATERMARK AT VENICE PINEBROOK FL LLC
WATERMARK COMMUNITIES INC
WATERPROOFING & ROOFING DESIGN
WATERPROOFING CONTRACTORS OF FLORIDA LLC
WATERS OF REFLECTION INC
WATERSCAPES POOLS & SPAS
WATERSIDE MECHANICAL INC
WATERTITE ROOFING COMPANY
WATKINS CONSTRUCTION LLC
WATKINS CONTRACTING LLC
WAVE POWER ELECTRIC LLC
WAYFARE ENERGY LLC
WAYLON'S ROOFING INC
WAYNE AUTOMATIC FIRE SPRINKLERS INC
WAYNE JUCHNO (OWNER BUILDER)
WAYPOINT ELECTRIC INC
WB WILLIAMSON BROS ROOFING INC
WCI COMMUNITIES INC
WCI COMMUNITIES INC
WCMHS
WCS CONSTRUCTION INC
WDR TECHNOLOGY, CORP.
WE CARE AIR LLC
WE DO IT ALL HANDYWORK LLC
WEATHER CHEK ELECTRIC INC
WEATHER CONTROL AIR COND INC
WEATHER TITE WINDOWS
WEATHERSHIELD ROOFING AND SHEETMETAL, LLC
WEATHERTIGHT SYSTEMS INC
WEAVER AIR INC
WEBSTER CONTRACTING
WEEKS MACHINE SHOP
WEHR CONSTRUCTORS INC
WEILER CONSTRUCTION INC
WEILER ROOFING INC
WEINMAN CONCRETE LLC
WEINTRAUB ENGINEERING AND INSPECTIONS, INC- A SAFEBUILT COMP
WEL ELECTRIC
WELCH TENNIS COURTS INC
WELL BILT INDUSTRIES USA
WELL ELECTRIC TECHNOLOGY INC
WELLER ROOFING & ALUMINUM
WEN CHUNG INC
WENDEMEN CONSTRUCTION INC
WENDLE SHEET METAL INC
WENIGER ELECTRIC LLC
WENTCO INC
WENTZELS ELECTRICAL SERVICES
WENTZELS HEATING & AIR CONDITIONING INC
WENZEL ELECTRICAL SERVICES INC
WES INDUSTRIES INC
WEST BAY ENERGY LLC
WEST BAY HOME SERVICES LLC
WEST CENTRAL SIGNS INC
WEST COAST CONSTRUCTION
WEST COAST COOLING & HEATING INC
WEST COAST COOLING LLC
WEST COAST CUSTOM CONSTRUCTION
WEST COAST CUSTOM FENCE INC
WEST COAST ELECTRICAL AND LIGHTING SERVICES
WEST COAST ELECTRICAL CONTRACTORS INC
WEST COAST EXTERIORS
WEST COAST FL ENTERPRISES INC
WEST COAST HEATING & AIR CONDITIONING
WEST COAST MASONRY LLC
WEST COAST MOBILE HOME SETUP
WEST COAST SIGNS
WEST COAST SIGNS INC
WEST COAST UNDERGROUND INC
WEST FIELD CUSTOM HOMES INC
WEST FLORIDA CONTRACTORS INC
WEST FLORIDA LANDSCAPE & TREE
WEST FLORIDA OVERHEAD DOORS LL
WEST SHORE CONSTRUCTION CORPORATION
WEST SHORE HOME LLC
WESTCOAST ELECTRIC SERVICES INC
WESTFALL CONSTRUCTION INC
WESTFIELD CUSTOM HOMES INC
WESTIN HILLS CORP
WESTMAN AND SONS ROOFING, LLC
WESTSHORE BUILDERS LLC
WESTSHORE HOME IMPROVEMENT LLC
WESTWATER CONSTRUCTION INC
WESTWIND AIR INC
WETHERINGTON RESTORATION AND REMODELING INC
WF GRIESMEYER MASONRY INC
WG MILLS INC
WG SINGLETARY CONSTRUCTION INC
WG YATES & SONS CONST CO
WGGC STREFLING CONSTRUCTION INC
WH ALDERMAN PLUMBING & HEATING
WHEELER ELECTRIC
WHIPPO COMPANY INC
WHITE ALUMINUM & WINDOWS, LLC
WHITE ALUMINUM & WINDOWS, LLC
WHITE ELECTRICAL CONST CO
WHITE ELECTRICAL SOLUTIONS LLC
WHITE'S A/C AND REFRIGERATION
WHITLOW REMODELING AND HOME MAINTNANCE LLC
WHITSON ELECTRICAL SERVICES
WHITTINGTON ELECTRIC INC
WHM SERVICES LLC
WIGGINS CONSTRUCTION INC
WIGINTON FIRE SYSTEMS
WILD ROOFING LLC
WILHITE ALUMINUM INC
WILL WOODSMALL CONSTRUCTION INC
WILLIAM EDWARD FREYER DBA BETTER POOLS AND SPAS
WILLIAM GUY WILLIAMS
WILLIAM P DONNELLY INC
WILLIAM R FLYNN CONTRACTOR INC
WILLIAM RICHARD STANCEL
WILLIAM SCHORK COMPLETE AIR SERVICES CORP
WILLIAM SCHORK COMPLETE HOME BUILDERS INC
WILLIAM SCHORK COMPLETE POOL SERVICES, INC.
WILLIAM SKAGGS
WILLIAM TROYER CONSTRUCTION
WILLIAM TROYER CONSTRUCTION
WILLIAM WAYNE PETERSON
WILLIAMS & ROWE COMPANY INC
WILLIAMS PLUMBING HEATING AND AIR LLC
WILLIAMS SCOTSMAN INC
WILLIS A SMITH CONSTRUCTION
WILLIS ELECTRIC INC
WILLIS ELECTRIC LLC
WILSON & COMPANY INC
WILSON POWER INC
WILSON WINDOW GLASS & MIRROR
WILSON'S PETROLEUM EQUIPMENT
WIMPYS DEPENDABLE PLUMBING
WINBERRY HOMES,LLC
WINDEMERE HOMES INC
WINDEMULLER TECHNICAL SERVICES
WINDGATE HOMES INC
WINDLOCH HOMES INC
WINDMAR HOME FLORIDA, INC.
WINDOW & DOOR DESIGN CENTER OF FLORIDA COMPANY
WINDOW & DOOR STORM PROTECTION PROFESSIONALS LLC
WINDOW SOLUTIONS PLUS INC
WINDOW SUPPLY INC
WINDOW WORLD OF SARASOTA
WINDOW WORLD OF SW FL
WINDOWS FOR LIFE INC
WINDOWS, DOORS, SHUTTERS & MORE LLC
WINDOWWALL LLC
WINDSHUTTERS
WINDSOR ELECTRIC INC
WINDSTORM MITIGATION INC
WINDWARD BUILDING GROUP INC
WINGATE ELECTRIC INC
WINGFIELD SERVICES INC
WINTER PARK CONSTRUCTION
WIRED UP ELECTRICAL SERVICE LLC
WJ BACHMAN MECH SHEET METAL CO
WJC & SON GENERAL CONTRACTING
WM F MCDONOUGH PLUMBING INC
WM F MCDONOUGH PLUMBING INC (FIRE)
WM ROBERTS ELECTRICAL AND MECHANICAL INC
WM SHEPHERD CONSTRUCTION INC
WOFFORD ROOFING & SOLAR
WOLCOTT CONSTRUCTION LLC
WOLF CONSTRUCTION OF SW FLA
WOLF ELECTRIC COMPANY INC
WOLF PLUMBING LLC
WOLFF CONSTRUCTION LLC
WOLFF ROOFING LLC
WOLVERINE AIR INC
WOODHAVEN CONSTRUCTION
WOODLAND CONSTRUCTION OF SW FL
WOODMANCY INC
WOODRUFF & SONS INC
WORKHORSE BUILDERS LLC
WORKMAN'S WINDOWS & DOORS,LLC
WORTHMANN LLC
WORTHY BUILDING COMPANY LLC
WP CONTRACTING GROUP, LLC
WP HICKS CONSTRUCTION INC
WPCS INTERNATIONAL SARASOTA
WR CARLSON ROOFING SPECIALIST
WR ROHN INC
WRIGHT WAY BUILDERS INC
WRIGHTS IMPACT WINDOW & DOOR LLC
WRIGHTWAY EMERGENCY SERVICES
WTD HOLDINGS INC DBA CT DARNELL CONSTRUCTION
WTH TECHNOLOGIES GROUP INC.
WYATT FISHER CONTRACTING LLC
WYLEE WEST ORTON
WYMAN PLUMBING INC
XANDO ENERGY LLC
XECUTIVE POOLS, LLC
XJG ENTERPRISES INC
XTREME ROOFING SERVICES INC
YARA INTERNATIONAL INC
YD GLOBAL ELECTRIC INC
YG&B SERVICES
YODER CONSTRUCTION SERVICES LLC
YODER CONTRACTORS LLC
YODER ENTERPRISES INC
YODER HOMES LLC
YONKERS TRACTOR SERVICE
YOUBAR BUILDERS INC
YOUNG CONTRACTING SE INC
YOUNG'S COMMUNICATIONS, LLC
YOUNG'S ELECTRICAL CONTRACTING
YOUR ELECTRIC
YOUR HOME OF FLORIDA LLC
YOUR HOME STORE LLC
Z BOS ELECTRICAL LLC
Z DEVELOPMENT SERVICES
Z PLUMBER INC
Z-SOURCE CONSTRUCTION INC
ZAC CLINE PLUMBING LLC
ZAGGIA ELECTRIC COMPANY INC
ZAP ELECTRIC INTERNATIONAL INC
ZEHR CONSTRUCTION LLC
ZENDA PLUMBING, LLC
ZEUS ELECTRIC LLC
ZINN'S GAS SERVICE INC
ZOLLER ROOFING INC
ZSP CONSTRUCTION LLC
ZWIERCAN HOMES INC
Password:
Password:
Remember Me
Forgot Password
/Forgot Username
Permits
Apply for New Permit
Search Permit
Pay Fees
Fees Estimator
View on Map
Projects
Apply for New Project
Search Projects
Pay Fees
Fees Estimator
View on Map
Contractors
Search Contractors
Pay Fees
Properties
Search Property
View on Map
Inspections
Schedule
View on Map
Cancel
Scheduled
Business Tax Receipt
Apply for New
Search
Pay Fees
Renew
Violations
Search
Pay Fees
Map
View Map
Locate My Address
Shopping Cart
Pay All Fees
Paid Items
Contact
Contact us
PreLoader
Permit Search
Search By
Search By:
PERMIT_NO
SITE_APN
SITE_ADDR
PERMITTYPE
PERMITSUBTYPE
Search Operator:
Begins With
Contains
Equals
At Least
At Most
Search Value:
Search More Results
Map
Map Frame
No results
Search
Loading...
Permits
Buttons
Search Results
Search Results
Results below
Search Details
Permit #
BLD24-05588
Inspections
Permit Info
Site Info
Contacts **
Fees $9,032.48
Inspections(29)
Reviews(9)
Permit Info
Type:
RESIDENTIAL NEW
Subtype:
SINGLE FAMILY DETACHED
SCOPE OF WORK:
1704 LUGANO CIR-NEW SFRD
Status:
ISSUED
Applied Date:
8/16/2024
Approved Date:
9/6/2024
Issued Date:
9/6/2024
Finaled Date:
Expiration Date:
7/29/2025
Notes:
8/16/2024 2:51:00 PM CAS L52
Linked Activities
Linked Activities:
 
Permit(s)
Sub Permits
ENG24-05590
ENGINEERING
ISSUED
Parcel Info
Address:
1704 LUGANO CIR
City/State/Zip:
NOKOMIS, FL, 34275
Property Type
PARCEL
Parcel #:
0380030052
Subdivision:
CASSATA LAKES PHASE 1
Tract:
TRACT G
Block:
Lot:
52
Section TWP RNG:
29-38S-19E
Lot Sq. Ft.:
9830
Linked Activities
Web Links
Attachments
Contact Type
Name
Phone
E-mail
Address
City/State/Zip
OWNER
CASSATA PROPERTIES LLC
()-
JMARTIN@MIHOMES.COM
7507 S TAMIAMI TRL
SARASOTA, FL 34231
APPLICANT
M/I HOMES OF FT.MYERS/NAPLES, LLC
(239)229-7021
info@suncoastpermits.com
25074 OLYMPIA AVE
PUNTA GORDA, FL 33950
CONTRACTOR
M/I HOMES OF FT.MYERS/NAPLES, LLC
(239)229-7021
JMARTIN@MIHOMES.COM
25074 OLYMPIA AVE
PUNTA GORDA, FL 33950
SUBCONTRACTOR 1
MID COAST ROOFING INC
(941)780-8713
OFFICE@MIDCOASTROOF.COM
1407 26TH AVE E
BRADENTON, FL 34208
ELECTRICAL CONTRACTOR
STRADA SERVICES, LLC
(888)831-2665
Oelec1@StradaElectric.com
3400 ST JOHNS PARKWAY
SANFORD, FL 32771
MECHANICAL CONTRACTOR
ARCTIC AIR SERVICES INC
(941)747-8800
INFO@ARCTICAIR4ME.COM
6870 26TH CT E
SARASOTA, FL 34243
PLUMBING CONTRACTOR
ARCTIC AIR SERVICES INC
(941)747-8800
INFO@ARCTICAIR4ME.COM
6870 26TH CT E
SARASOTA, FL 34243
Description
Amount
Paid Date
PERMIT FEES
$2,928.16
9/4/2024
SSC IMPACT FEE GROUP
$7,240.27
STATE FEES
$66.12
9/4/2024
UTILITY FEES
$0.00
ZONING FEES
$308.81
9/4/2024
ENGINEERING FEES
$28.29
9/4/2024
COV FIRE IMPACT FEE
$489.99
COV LAW IMPACT FEE
$386.80
COV SOLID WASTE IMPACT FEE
$422.08
COV GEN GOV IMPACT FEE
$493.34
SSC MOBILITY FEE GROUP
$3,864.88
9/4/2024
Total Fees
Charged:
$16,228.74
Balance Due:
$9,032.48
Type
SEQ#
Result
Scheduled Date
Time
Completed
Time
More Info
ELECTRICAL ROUGH 202
50
1/31/2025
More Info
HVAC ROUGH 301
50
APPROVED
1/30/2025
1/30/2025
More Info
2ND PLUMBING ROUGH 402
50
APPROVED
1/30/2025
1/30/2025
More Info
ELECTRICAL ROUGH 202
50
DISAPPROVED
1/30/2025
1/30/2025
More Info
ROOF DRY IN 109
40
APPROVED
1/29/2025
1/29/2025
More Info
TRUSS TIEDOWN 111
40
APPROVED
1/24/2025
1/24/2025
More Info
T-POLE/TUG 203
40
APPROVED
1/21/2025
1/21/2025
More Info
WALL SHEATHING 107
40
APPROVED
12/5/2024
12/5/2024
More Info
ROOF SHEATHING 108
40
APPROVED
12/5/2024
12/5/2024
More Info
WINDOW/DOOR BUCK 110
40
APPROVED
12/5/2024
12/5/2024
More Info
LINTEL/PILASTER/BEAM 106
40
APPROVED
11/19/2024
11/19/2024
More Info
SPOT SURVEY 802
30
APPROVED
11/12/2024
11/12/2024
More Info
SLAB/ELEC UNDERGROUND 204
10
APPROVED
10/28/2024
10/28/2024
More Info
MONO SLAB 103
10
APPROVED
10/28/2024
10/28/2024
More Info
GROUNDING (FOOTER STEEL) 201
10
APPROVED
10/28/2024
10/28/2024
More Info
SEWER 404
0
APPROVED
10/4/2024
10/4/2024
More Info
1ST PLUMBING ROUGH 401
10
APPROVED
10/4/2024
10/4/2024
More Info
WATER SERVICE 403
0
APPROVED
10/4/2024
10/4/2024
More Info
**BUILDING FINAL 199
100
More Info
BACKFLOW 405
0
More Info
ELECTRICAL FINAL 298
90
More Info
FRAMING 114
60
More Info
HVAC FINAL 398
90
More Info
INSULATION 115
70
More Info
PLUMBING FINAL 498
90
More Info
ROOF IN PROGRESS 112
50
More Info
SOFFIT/F CHANNEL IN PROGRESS 124
70
More Info
STUCCO LATHE/VENEERS 125
70
More Info
TREE FINAL 804
90
More Info
Type
Reviewer
Status
Submitted
Completed
Due Date
More Info
BUILDING PLAN
Paul Rakes
APPROVED
8/16/2024
8/20/2024
8/22/2024
More Info
ENGINEERING PLAN
Jeffrey Hackett
APPROVED
8/16/2024
8/19/2024
8/20/2024
More Info
FIRE PLAN
Jack Stevenson
APPROVED
8/16/2024
8/23/2024
8/20/2024
More Info
FLOOD HAZARD AREA
Paul Rakes
EXEMPT
8/16/2024
9/3/2024
More Info
IMPACT FEE REVIEW
Kimberly Back
APPROVED
8/16/2024
8/16/2024
8/20/2024
More Info
INTAKE REVIEW
INTAKE BUCKET
APPROVED W/CONDITIONS
8/16/2024
8/19/2024
8/19/2024
More Info
TREE PERMIT REVIEW
Jim Yelverton
EXEMPT
8/16/2024
8/20/2024
8/22/2024
More Info
ZONING PLAN
Kelsey Shope
APPROVED
8/16/2024
9/3/2024
8/22/2024
More Info
PROCESS REVIEW
PROCESS BUCKET
APPROVED
8/20/2024
9/6/2024
8/22/2024
More Info
X